Motherboard Components/ 主板组件
No. Code Descripon
1 CPU Intel Xeon® processor D-1541, FCBGA1667 SoC (MB10-DS3)
2 SFP+1_2 SFP+ connectors #1/#2
3 LAN1_2 LAN ports
4 USB3_MLAN BMC Management LAN port (top) / USB 3.0 ports (boom)
5 CPU0_FAN CPU fan connector
6 VGA VGA port
7 SW_ID ID switch buon w/LED
8 SW_PWR Power buon w/LED
9 LED_STA System Status LED
10 P12V_AUX1 8 pin power connector
11 FP_1 Front panel header
12 ATX1 24 pin main power connector
13 DIMM_P0_A0 Channel 1 slot 0
14 DIMM_P0_A1 Channel 2 slot 1
15 DIMM_P0_B0 Channel 3 slot 0
16 DIMM_P0_B1 Channel 4 slot 1
17 BAT1 Baery
18 PMBUS PMBus connector
19 SATA_DOM0 SATA DOM power cable connector
20 SATA0 SATA 3 6Gb/s connector
21 SATA1 SATA 3 6Gb/s connector
22 SATA_2_3 SATA 3 6Gb/s connectors
23 SATA_4_5 SATA 3 6Gb/s connectors
24 SATA_SGPIO SATA SGPIO header
25 COM1 Serial port cable connector
26 LED_BMC1 BMC firmware readiness LED
27 BP_1 HDD back plane board header
28 NVME_PH NVME connector
29 TPM TPM module connector
30 IPMB IPMB connector
No. Code Descripon
31 CLR_CMOS Clear CMOS jumper
1-2 Close: Normal operaon (Default seng)
2-3 Close: Clear CMOS data.
32 PCIE_1 PCI Express p1-x16 slot
33 ME_UPDATE ME update jumper
1-2 Close: Normal operaon (Default seng)
2-3 Close: ME update mode.
34 ME_RCVR ME recovry jumper
1-2 Close: Normal operaon. (Default seng)
2-3 Close: ME recovery mode.
35 S3_MASK S3 Power On Select jumper
1-2 Close: Stop an inial power on when BMC is not ready.
2-3 Close: Keep inial power on. (Default seng)
1
32 4 5 6 7 8 9
12
10
11
13141516
19 18
17
2021222325
24
262728
30
29
31
32
33
34
35
System Components/ 系统组件
No Descripon
1 HDD bays
2 System fan #9/#10 (FAN9/FAN10)
3 System fan #7/#8 (FAN7/FAN8)
4 System fan #5/#6 (FAN5/FAN6)
5 System fan #3/#4 (FAN3/FAN4)
6 System fan #1/#2 (FAN1/FAN2)
7 CPU and CPU heat sink
8 Memory slots
9 PCIe riser bracket
10 Power supply cage
CAUTION!
To connect system fan connector, follow the instrucon:
Blue/Red cable connect to odd numbered connector.
White/Amber cable connect to even numbered connector.
注意!
蓝/红电缆连连接于单数风扇插座。
白/橘电缆连连接于双数风扇插座。
Front Panel Header/ 前面板接头
No. Pin Define
1 Power LED+
3 No Pin
5 Power LED-
7 HDD LED+
9 HDD LED-
11 Power Buon
13 GND
15 Reset Buon+
17 GND
19 ID Switch+
21 ID Switch-
23 NMI Switch-
No. Pin Define
2 5V Standby
4 ID LED+
6 ID LED-
8 System Front Board LED+
10 System Status LED-
12 LAN1 Acve LED+
14 LAN1 Link LED-
16 SMBus Data
18 SMBus Clock
20 Case Open
22 LAN2 Acve LED
24 LAN2 Link LED-
1
2423
2
HDD Back Plane Board Header/ 硬盘驱动器底板接头
1 2
25 26
No. Pin Define
1 BP_SGP_CLK
3 BP_SGP_GLD
5 BP_SGP_DOUT
7 Key Pin
9 GND
11 BP_LED_G_N
13 BP_SGP_DIN
15 GND
17 GND
19 P_3V3_AUX
21 P_3V3_AUX
23 GND
25 BP_PRESENSE
No. Pin Define
2 No Connect
4 FAN_SGP_Gate
6 GND
8 Reset
10 BP_LED_A_N
12 GND
14 No Connect
16 SMB_BP_DATA
18 SMB_BP_CLK
20 BMC_ACK
22 BMC_REQ
24 Key Pin
26 GND
CAUTION!
Before you remove or install the system
cover:
Make sure the system is not turned on
or connected to AC power.
注意!
在卸下或安装系统机盖之前,请注意
下列事项:
确保系统未开启且未连接到交流电源。
System Cover/ 机箱盖
1
1
1
2
3
4
Fan Duct/ 风扇散热片
1
2
Memory Populaon Configuraon/ 安装内存
Type
Ranks PerDIMM
and
Data Width
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
Speed (MT/s);
Slot Per Channel (SPC) and DIMM Per Channel (DPC)
1 Slot Per Channel
1DPC
2 Slot Per Channel
1DPC 2DPC
RDIMM
RDIMM
RDIMM
RDIMM
SRx4 ECC
SRx8 ECC
DRx8 ECC
DRx4 ECC
仅Intel Xeon D-1541处理器支持DDR4-MHz内存。®
只使用一个DIMM时,必须安装到内存插槽0。
若安装顺序有误,系统将不能正常引导。
Note: DDR4 2400MHz is only available on Intel Xeon® D-1541 processor.
When only one DIMM is used, it must be populated in memory slot0 first.
System will not boot normally with incorrect populated sequence.
System Fan/ 系统风扇
CAUTION!
Before you remove or install the system fan:
Make sure the system is not turned on or
connected to the AC power.
Disconnect all necessary cable connecons.
Failure to observe these
warnings could result in personal injury or
damage to the equipment.
注意!
确保系统未开机且未连接到交流电源。
断开所有必要的线缆连接。若不遵循这些
警告,可能造成人员伤害或设备损坏。
1
2
CAUTION!
Read the following guidelines before you begin to install the Hard disk drive:
Take note of the drive tray orientaon before sliding it out.
The tray will not t back into the bay if inserted incorrectly.
Make sure that the HDD is connected to the HDD connector on the backplane.
注意!
在滑出驱动器托盘之前,注意其方向。
托盘插入不当时,无法进入托槽。
确保硬盘驱动器连接到底板上的硬盘驱动
器底板。
No Descripon
1 HDD#3
2 HDD#2
3 HDD#1
4 HDD#0
5 SGPIO header
6 Fan connector#13
7 Fan connector#14
8 Fan connector#11
9 Fan connector#12
10 ODD power connector
11 Fan connector#9
HDD Backplane Board Components
No Descripon
12 Fan connector#10
13 Fan connector#7
14 Fan connector#8
15 Fan connector#5
16 Fan connector#6
17 Fan connector#3
18 Fan connector#4
19 Fan connector#1
20 Fan connector#2
21 Fan connector#15
22 Fan connector#16
Hard Disk Drive and Back Plane Board/ 硬盘驱动器与硬盘驱动器底板
5
1234
6 7 8 9
10
11 12 13 14 15 16 17 18 19 20 21 22
3
44
1
2
System Front View System Rear View
No Descripon
1 ID buon w/LED
2 Power buon w/LED
3 HDD bays
No Descripon
1 Power supply fan
2 Power supply module cord socket
3 System Status LED
4 Power buon w/LED
5 ID switch buon w/LED
6 VGA port
7 USB 3.0 ports
8 10/100/1000 Server management LAN port
9 GbE LAN ports
10 SFP+ LAN ports
Front & Rear/ 系统前部与后部概览
Off
State Description
Yellow On 1Gbps data rate
Green On 100Mbps data rate
10Mbps data rate
State Description
Yellow On 1Gbps data rate
Green On 10 Gbps data rate
Speed LED Link/Acvity
LED
Speed LED Link/Acvity
LED
SFP+ LAN LED:
ID buon/LED:Power buon/LED:
Blue On System identifcation is active.
Off System identifcation is disabled.
State Description
Green On
Off
Description
System is powered on
System is powered off
State
1 2
3
1 2 3
45 6 7 8 9 10
PCI Express Card/PCI Express 扩展卡
注意!
在安装扩展卡前,请注意下列事项:
确保系统未开启且未连接到交流电源。
CAUTION!
Before you remove or install the PCI express card:
Make sure the system is not turned on or connected to AC power.
1
2
3
4
5
6
7
8
注意!
在替换或安装电源前,请注意下列事项:
确保系统未开启且未连接到交流电源
CAUTION!
Before you remove or install the power
supplies:
Make sure the system is not turned on or
connected to AC power.
Power Supply/ 电源
1
2
3
Rail Kit/ 导轨
Release
Lock out
⯮ⅎ庳⎽⇡
Release and de ch the inner member from the slideta
1
M4X6
Click
Aach the unit to the inner member
⯭Ⅼ彏擨
㜡⏗
2
Release
lock in
Insert the unit to complete the in nstallao
墬⅌㜡㞝
4
Brac tke
M6X13
M6-NUT
Fix the outer member/bracket assembly to the frame
⯭⣽彏㈿㞝擨⅌㜡㞝
3
Front Panel LED and Buons/ 前面板 LED 说明
7复位按钮 按此按钮启动系统。
8复位按钮 按此按钮启动不可遮罩中断功能。
2按下按钮启动系统识别功能。ID按钮
1系统处于开机状态。
系统处于ACPI S1状态(睡眠模式)。
系统未开机或处于ACPIS5状态(关机状态)。
系统处于ACPI S4状态(休眠模式)。
电源按钮和LED 绿色
绿色
恒亮
不亮
闪烁
无亮灯
不亮 断开连接/待机无亮灯
5/6 恒亮
闪烁
系统和网络之间的链接
网络访问
绿色
绿色
LAN1/LAN2活动LED
6硬盘驱动器定位
硬盘驱动器访问
硬盘驱动器访问
硬盘故障
无硬盘驱动器访问
绿色
橙色
绿色/橙色
不亮
闪烁
无亮灯
硬盘驱动器LED
闪烁
编号 名称 颜色 状态 说明
3系统正常运行
橙色
绿色
系统状态LED 恒亮
恒亮
不亮
不亮
闪烁
无亮灯
效能降低情形,可能为下列状况:
处理器问题
内存问题
严重情形,可能为下列状况:
电源模块故障
系统风扇故障
电源电压问题
系统温度/电压问题
非严重情形,可能为下列状况:
冗余电源模块故障
系统温度/电压问题
机箱侵入
系统未正常运行,可能为下列状况:
POST错误
NMI错误
处理器或终结器缺失
No. Name Color Status Description
7Reset Button Press the button to reset the system.
8NMI Button Press the button to generate an NMI.
2 Press the button to activate system identifcation.ID Button
1 System is powered on.
System is in ACPI S1 state (sleep mode).
System is not powered on or in ACPI S5 state (power off).
System is in ACPI S4 state (hibernate mode).
Power Button and LED Green
Green
Solid On
Off
Blink
N/A
4HDD locate
HDD access
HDD access
HDD fault
No HDD access or no HDD fault.
Green
Amber
Green/Amber
On
Off
Blink
On
Blink
N/A
HDD Status LED
5/6 Link between system and network or no access.
Data transmission or receiving is occurring.
No data transmission or receiving is occurring.
Solid On
Off
Blink
Green
Green
N/A
LAN1/2 Active/Link LEDs
状态
3 System is operating normally.
Degrade condition, may indicates:
CPU failure
DIMM killed
System Status LED
Green
Amber
Solid On
Critical condition, may indicates:
Power module failure
System fan failure
Power supply voltage issue
System temperature
Solid On
Non-critical condition, may indicates:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
System is not ready, may indicates:
POST error
NMI error
Processor or terminator missing
Blink
N/A N/A
Off
12345678
G150-B10 Quick Installaon Guide/G150-B10 快速安装说明
10/100/1000 LAN LED:
1
23456
7
9
8
10
PN:25ME0-G15000-CLS


Produkt Specifikationer

Mærke: Gigabyte
Kategori: Server
Model: G150-B10

Har du brug for hjælp?

Hvis du har brug for hjælp til Gigabyte G150-B10 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Server Gigabyte Manualer

Gigabyte

Gigabyte TO24-JD0 Manual

15 December 2024
Gigabyte

Gigabyte MS33-CP0 Manual

31 August 2024
Gigabyte

Gigabyte R133-X11 Manual

31 August 2024
Gigabyte

Gigabyte R183-S97 Manual

31 August 2024
Gigabyte

Gigabyte R113-C10 Manual

31 August 2024
Gigabyte

Gigabyte R183-SF0 Manual

31 August 2024
Gigabyte

Gigabyte R133-X13 Manual

31 August 2024
Gigabyte

Gigabyte R183-S96 Manual

31 August 2024
Gigabyte

Gigabyte R123-X00 Manual

31 August 2024
Gigabyte

Gigabyte R243-EG0 Manual

31 August 2024

Server Manualer

Nyeste Server Manualer