Gigabyte G291-281 Manual

Gigabyte Server G291-281

Læs nedenfor 📖 manual på dansk for Gigabyte G291-281 (144 sider) i kategorien Server. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/144
Gigabyte Management Console
User's Guide
Rev. 1.0
Copyright
© 2021 GIGA-BYTE TECHNOLOGY CO., LTD. All rights reserved.
The trademarks mentioned in this manual are legally registered to their respective owners.
Disclaimer
Information in this manual is protected by copyright laws and is the property of GIGABYTE.
Changes to the specifications and features in this manual may be made by GIGABYTE
without prior notice. No part of this manual may be reproduced, copied, translated, transmitted, or
published in any form or by any means without GIGABYTE's prior written permission.
Documentation Classications
In order to assist in the use of this product, GIGABYTE provides the following types of documentation:
 UserManual:detailedinformation&stepsabouttheinstallation,congurationandusethis
  product(motherboard),coveringhardware,BIOSandBMCrmware.
  ServiceGuide:detailedinformation&stepsabouttheinstallation,congurationanduseof
this product (server barebones), covering hardware & BIOS
Quick Installation Guide: a short guide with visual diagrams that you can reference easily for
installation purposes
Please see the support section of the online product page to check the current availability of these
documents
For More Information
Forrelatedproductspecications,thelatestrmwareandsoftware,andrelatedinformation,pleasevisit
our website at:
http://www.gigabyte.com
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our
reseller portal:
http://reseller.b2b.gigabyte.com
For further information & technical assistance, please contact your GIGABYTE sales representative.
You may also message GIGABYTE server directly by email, Facebook or twitter
Email: server.grp@gigabyte.com
Facebook: https://www.facebook.com/gigabyteserver
Twitter: https://twitter.com/GIGABYTEServer
- 3 -
Table of Contents
Chapter 1 Getting Started 5 ...............................................................................................
1-1 Software Requirement 5 .....................................................................................
1-2 GigabyteManagementConsoleNetworkConguration .................................. 6
1-3 Log In Gigabyte Management Console 7 ............................................................
1-3-1 Required Browser Settings: 9 ......................................................................................
1-4 Quick Button and Logged-in User 10 ..................................................................
1-5 Help ................................................................................................................ 11
1-6 Menu Bar ........................................................................................................ 11
Chapter 2 Enter Gigabyte Management Console 13 .........................................................
2-1 Dashboard ...................................................................................................... 13
2-2 Sensor ............................................................................................................ 14
2-2-1 Sensor Detail 15 ..........................................................................................................
2-3 System Inventory 17 ...........................................................................................
2-3-1 CPU Inventory 17 ........................................................................................................
2-3-2 DIMM Inventory 18 ......................................................................................................
2-3-3 PCI Inventory 18 ..........................................................................................................
2-3-4 HDD Inventory 19 ........................................................................................................
2-3-5 NIC Inventory 19 ..........................................................................................................
2-3-6 GPU Inventory 20 ........................................................................................................
2-4 FRU Information 22 .............................................................................................
2-5 Logs & Reports 24 ..............................................................................................
2-5-1 IPMI Event Log 24 .......................................................................................................
2-5-2 System Log 26 .............................................................................................................
2-5-3 Audit Log 27 ................................................................................................................
2-5-4 Video Log 28 ...............................................................................................................
2-6 Settings .......................................................................................................... 29
2-6-1 Captured BSOD 29 .....................................................................................................
2-6-2 Date & Time ............................................................................................................30
2-6-3 External User Services 31 ...........................................................................................
2-6-4 KVM Mouse Settings 42 ..............................................................................................
2-6-5 Log Settings 44 ............................................................................................................
2-6-6 Media Redirection Settings 47 .....................................................................................
2-6-7 Network Settings 54 ....................................................................................................
2-6-8 NVMe MI Management 61 ...........................................................................................
2-6-9 PAM Order Settings 63 ................................................................................................
2-6-10 Platform Event Filter 64 ...............................................................................................
2-6-11 Services ..................................................................................................................73
- 4 -
2-6-12 SMTP Settings 77 ........................................................................................................
2-6-13 SSL Settings 80 ...........................................................................................................
2-6-14 System Firewall 85 ......................................................................................................
2-6-15 User Management 95 ..................................................................................................
2-6-16 Video Recording 100 ...................................................................................................
2-6-17 Fan Policy 109 .............................................................................................................
2-6-18 Power Consumption ............................................................................................. 111
2-7 Remote Control 103 ............................................................................................
2-8 Images Redirection 109 ......................................................................................
2-8-1 Remote Media ......................................................................................................110
2-9 Power Control ...............................................................................................111
2-10 Maintenance Group ...................................................................................... 112
2-10-1 BackupConguration ...........................................................................................113
2-10-2 Firmware Image Location .....................................................................................115
2-10-3 Firmware Update ..................................................................................................116
2-10-4 HPM Firmware Update 122 .........................................................................................
2-10-5 Firmware Information 125 ............................................................................................
2-10-6 PreserveConguration .........................................................................................126
2-10-7 RestoreConguration ...........................................................................................131
2-10-8 Restore Factory Defaults 132 ......................................................................................
2-10-9 System Administrator ............................................................................................133
2-10-10 Sign Out 134 ................................................................................................................
- 5 - Getting Started
1-1 Software Requirement
• Client machine with 8GB RAM.
• If the client machine has 4GB RAM, there will be lag in Video/keyboard/mouse
functionality.
•
Supported Browsers
• Chrome latest version.
• IE 11 and above.
• Firefox (with limited support).
It is advisable to use Chrome or IE for H5Viewer, since Firefox has its own Note:
memory limitations
Chapter 1 Getting Started
Getting Started - 6 -
1-2 Gigabyte Management Console Network Conguration
Follow the instruction to enable the console redirection function.
1. You can gather the IP address on the POST screen.
2. Or, Go to BIOS setup menu.
3. Select .Server Management
4. Select . BMC network Conguration
5. DeneCongurationAddresssourcetoDynamicBmcDhcporStatic.
6. Save and Exit.
7. The BMC IP Address will appear on the IPv4 Address parameter.
8. SavethecongurationandexitBIOSsetupmenu.
- 7 - Getting Started
1-3 Log In Gigabyte Management Console
To access the Gigabyte Management Console, the BMC Web utility will prompt you to enter the
User Name and Password.
Theeldsareexplainedasfollows:
For basic login to the BMC Web UI, use the following login:
Username: admin
Password: Refer to unique MB serial number.
NOTE!
If your motherboard / server version is older than G9 (upgrade version), then use the
following login:
Username:admin
Password: password
This serial number can be found on the serial number sticker located on the motherboard of
every GIGABYTE server motherboard and system. The unique pre-programmed password will
be the last 11 characters of the serial number. For example, for the below serial number, the
password will be “JG4P6400027
Getting Started - 8 -
GIGABYTEwillalsoafxnewstickersthatdisplaytheuniqueBMCpassword(examplebelow)to
both the product box (packaging) and to the CPU cover (for motherboards sold separately) or the
server chassis.
Please see the reference guide below / attached for where to find locations of this sticker
according to product / model type.
Products that have been implemented with this change will be indicated as version G9 on the
“Upgrade Version sticker located on the motherboard / motherboard anti-static packaging /
server chassis / server packaging
Remember Username: Check this option to remember your login credentials.
Sign me in: After entering the required credentials, click the to login to GUI.Sign me in
I forgot my password: If you forget your password, you can generate a new one using this link.
Enter the username, click on link. This will send the newly generated Forgot Password
passwordtotheconguredEmail-IDfortheuser.
- 9 - Getting Started
1-3-1 Required Browser Settings:
Allow le download from this site: For Internet Explorer, Choose Tools ->Internet Options
->Security Tab, based on device setup, select among Internet, Local intranet, trusted sites and
restricted sites. Click .... In the Security Settings - Zone dialog opened, under Custom level
settings, find Downloads option, Enable File download option. Click to the entire dialog OK
boxes.
ForallOtherBrowsers,acceptledownloadwhenprompted.
Enable javascript for this site: The icon indicates whether the javascript setting is enabled in
browser.
Enable cookies for this site: The icon indicates whether the cookies setting are enabled in
browser.
Cookies must be enabled in order to access the website.
Getting Started - 10 -
1-4 Quick Button and Logged-in User
The user information and quick buttons are located at the top right of the Web GUI. A screenshot
of the logged-in user information is shown below.
User Information
The logged-in user information shows the logged-in user, his/her privilege and the four quick
buttons allowing you to perform the following functions:
Logged-in user and its privilege level
Thisoptionshowsthelogged-inusernameandprivilege.Therearevekindsofprivileges.
User: Only valid commands are allowed.
Operator: All BMC commands are allowed except for the configuration commands that can
change the behavior of the out-of-hand interfaces.
Administrator: All BMC commands are allowed.
No Access: Login access denied.
OEM: All OEM commands are allowed.
Notication:Clicktheicontoviewthenoticationmessages.
Refresh: Click the icon to reload the current page.
Sync: Click the icon to synchronize with Latest Sensor and Event Log updates.
Sign-out: Click the icon to log out of the Web GUI.
Warning: Click to view the warning messages.
- 11 - Getting Started
1-5 Help
Help - The Help icon (?) is Located at the top right of the each page in Web GUI. Click this help
icontoviewmoredetailedelddescriptions.
1-6 Menu Bar
The menu bar displays the following:
Getting Started - 12 -
This page intentionally left blank
- 13 - Gigabyte Server Management Console
Chapter 2 Enter Gigabyte Management Console
2-1 Dashboard
The Dashboard page gives the overall information about the status of a device.
To open the Dashboard page, click from the menu bar. It displays the following:Dashboard
Dashboard
A brief description of the Dashboard page is given below.
BMC Up Time
It indicates the Power On time.
Pending Deassertions
It lists the all pending events incurred by various sensors and occupied/available space in logs
can be viewed. To know about the pending events details, click the More info link. This navigates
to the Event Log page.
Access Logs
A graphical representation of all events incurred by various sensors and occupied/available space
in logs can be viewed, if you click on the More info link, you can view the Audit Log page.
Today & 30 Days (Event Logs)
This page displays the list of event logs occurred by the different sensors on this device. Click
Details link on Today and 30 days to view the event logs for Today and 30 days respectively.
Sensor Monitoring
It lists all the critical sensors on the device. If you click on any list sensor, you can view the
Sensor detail page with the Sensor information and Sensor Events details.
Gigabyte Server Management Console - 14 -
2-2 Sensor
The Sensor Readings page displays all the sensor related information.
To open the Sensor Readings page, click Sensor from the menu. Click on any sensor to show
more information about that particular sensor, including thresholds and a graphical representation
of all associated events.
A sample screenshot of Sensor Readings page is shown below.
The Sensor Readings page contains the following information:
In this Sensor Reading page, Live readings for all the available sensors with details like Sensor
Name, Status, Current Reading and Behavior will be appeared, else you can choose the sensor
type that you want to display from the list. Some examples for sensors are Temperature Sensors,
Fan Sensors, Watchdog Sensors and Voltage Sensors etc.
Note: Four DIMM Temp sensors are deployed for monitoring the DIMM temperature on the
system. Users must take notice that the live reading of each DIMM Temp sensor indicates the
temperatureofaDIMMgroup,notthetemperatureofaspecicDIMM.
- 15 - Gigabyte Server Management Console
: Four DIMM Temp sensors are deployed for monitoring the DIMM temperature on Note
the system. Users must take notice that the live reading of each DIMM Temp sensor
฀ indicates฀the฀temperature฀of฀a฀DIMM฀group,฀not฀the฀temperature฀of฀a฀speci฀c฀DIMM.
2-2-1 Sensor Detail
Select a particular Sensor from the Critical Sensor or Normal Sensor lists. The Sensor
Information as Live Widget and Thresholds for the selected sensor will be displayed as shown
below.
:For Illustrative Purpose, a sample screenshot of Sensor detail page with Change Note
Thresholds option is shown and explained below.
: Widgets are little gadgets, which provide real time information about a particular Note
฀ sensor.฀User฀can฀track฀a฀sensor's฀behavior฀over฀a฀speci฀c฀amount฀of฀time฀at฀speci฀c฀฀
intervals.The result will be displayed as a line graph in the widget. The session will not
expire, until the widgets gets a live data of the last widget that is kept opened.
For the selected sensor, this widget gives a dynamic representation of the readings for
Gigabyte Server Management Console - 16 -
the sensor.
There are six types of thresholds:
•฀ Lower Non-Recoverable (LNR)
•฀ Lower Critical (LC)
•฀ Lower Non-Critical (LNC)
•฀ Upper Non-Recoverable (UNR)
•฀ Upper Critical (UC)
•฀ Upper Non-Critical (UNC)
The threshold states could be Lower Non-critical - going low, Lower Non-critical - going high,
Lower Critical - going low, Lower Critical - going high, Lower Non-recoverable - going low, Low
Non-recoverable - going high, Upper Non-critical - going low, Upper Non-critical - going high
Upper Critical - going low, Upper Critical - going high, Upper Non-recoverable - going low, Uppe
Non-recoverable - going high.
A graphical view of these events (Number of Entries vs. Thresholds) can be viewed as shown in
the Sensor Readings page screenshot.
- 17 - Gigabyte Server Management Console
2-3 System Inventory
The System Inventory page displays the following information:
•฀ CPU Inventory
•฀ DIMM Inventory
•฀ PCI Inventory
•฀ HDD Inventory
•฀ NIC Inventory
•฀ GPU Inventory (Nvidia A100 only)
A screenshot displaying the menu items under System Inventory is shown below.
A detailed description of System Inventory is given below.
2-3-1 CPU Inventory
This page displays all detected CPUs on this device. Select one CPU to see the details of
that entry or click on Expand All to view all entries in details. Click Download SMBIOS ฀le to
download฀the฀SMBIOS฀฀le.฀
- 18 - Gigabyte Server Management Console
2-3-2 DIMM Inventory
This page displays all detected DIMMs on this device. It allows you to see memory attributes,
individual memory details or all entries in detail by clicking on . Click Expand All Download
SMBIOS ฀le฀to฀download฀the฀SMBIOS฀฀le.
2-3-3 PCI Inventory
This page displays all detected PCI cards on this device. It allows you to see on-board PCI cards,
add-on PCI cards or all entries in detail by clicking on . Click Expand All Download SMBIOS ฀le
to฀download฀the฀SMBIOS฀฀le.฀
- 19 - Gigabyte Server Management Console
2-3-4 HDD Inventory
This page displays all detected HDDs on this device. It allows you to see on-board HDDs, add-
on HDDs or all entries in detail by clicking on . Click Expand All Download SMBIOS file to
download฀the฀SMBIOS฀฀le.฀
2-3-5 NIC Inventory
This page displays all detected NICs on this device. It allows you to on-board NICs, add-on NICs
or all entries in detail by clicking on . Click to download the Expand All Download SMBIOS ฀le
SMBIOS฀฀le.฀
- 20 - Gigabyte Server Management Console
2-3-6 GPU Inventory
This page displays all detected GPU card on this device. It allows you to view GPU card all
entries in detail by clicking on . Expand All
Detail information for GPU
•฀ GPU Information
•฀ Capabilities
•฀ NVLink Information
Temperature Information for GPU
•฀ GPU Temperature
•฀ Extended Precision GPU Temperature
Status Information for GPU
•฀ Accumulated Utilization
•฀ Power Supply
- 21 - Gigabyte Server Management Console
Power Information for GPU
•฀ Power Consumption
Clock Information for GPU
•฀ Graphics Clock Frequency
•฀ -Memory Clock Frequency
- 22 - Gigabyte Server Management Console
2-4 FRU Information
FRU Information page displays the BMC’s FRU device information. FRU page shows information
like Basic Information, Chassis Information, Board Information and Product Information of the
FRU device.
To open the FRU Information page, click from the menu bar. Select a FRU FRU Information
Device ID from the FRU Information section to view the details of the selected device. A
screenshot of FRU Information page is shown below.
The฀following฀฀elds฀are฀displayed฀here฀for฀the฀selected฀device:
Available FRU Devices
•฀ FRU device ID - Select the device ID from the drop down list
•฀ FRU Device Name - The device name of the selected FRU device.
Chassis Information
•฀ Chassis Information Area Format Version
•฀ Chassis Type
•฀ Chassis Part Number
•฀ Chassis Serial Number
•฀ Chassis Extra
Gigabyte Server Management Console - 23 -
Board Information
•฀ Board Information Area Format Version
•฀ Language
•฀ Manufacture Date Time
•฀ Board Manufacturer
•฀ Board Product Name
•฀ Board Serial Number
•฀ Board Part Number
•฀ FRU File ID
•฀ Board Extra
Product Information
•฀ Board Information Area Format Version
•฀ Language
•฀ Manufacture Date Time
•฀ Board Manufacturer
•฀ Board Product Name
•฀ Board Serial Number
•฀ Board Part Number
•฀ FRU File ID
•฀ Board Extra
- 24 - Gigabyte Server Management Console
2-5 Logs & Reports
The Logs & Reports page displays the following information:
•฀ IPMI Event Log
•฀ System Log
•฀ Audit Log
•฀ Video Log
A screenshot displaying the menu items under Logs & Reports is shown below.
A detailed description of Logs & Reports is given below.
2-5-1 IPMI Event Log
This page displays the list of event logs occurred by the different sensors on this device. Double
click฀on฀a฀record฀to฀see฀the฀details฀of฀that฀entry.฀You฀can฀use฀the฀sensor฀type฀or฀sensor฀name฀฀lt
options฀to฀view฀those฀speci฀c฀events฀or฀you฀can฀also฀sort฀the฀list฀of฀entries฀by฀clicking฀on฀any
the column headers.
To open the Event Log page, click from the menu bar.Logs & Reports > IPMI Event Log
A sample screenshot of Event Log page is shown below.
Gigabyte Server Management Console - 25 -
The฀Event฀Log฀page฀consists฀of฀the฀following฀฀elds:
Filter By Date Start Date End Date: Filtering can be done by selecting and .
:Date should be in MM/DD/YYYY format. Note
By default, all log time will be displayed in BMC time zone.
Filter By Type: The category could be either All Events, System Event Records, OEM Event
Records, BIOS Generated Events, SMI Handler Events, System Management Software Events,
System Software - OEM Events, Remote Console software Events, Terminal Mode Remote
Console software Events.
:Once the Filter By Date and Filter type are selected, the list of events will Note
be displayed with the Event ID, Time Stamp, Sensor Type, Sensor Name and
Description.
Event Log Statistics: Displays the statistical graph for the selected date.
Clear Event Logs: To delete all the event logs.
Download Event Logs: To download the event logs.
Procedure
1. using From฀the฀Filter฀By฀Date฀฀eld,฀select฀the฀time฀period฀by฀Start Date End Date and
Calendar for the event categories.
2. From the Filter By Type ฀eld,฀select฀the฀Type Sensor of the event and name to view the
events for the date. The events will be displayed based on the selected time period.
3. To clear all events from the list, click .Clear All Event Logs
4. To download the event logs, click .Download Event Logs
- 26 - Gigabyte Server Management Console
2-5-2 System Log
To open the System Log page, click Logs & Reports > System Log from the menu bar. A
sample screenshot of System Log page is shown below.
A sample screenshot of Video Log page is shown below.
To฀view฀System฀Log,฀click฀the฀System฀Log฀tab฀to฀view฀all฀system฀events.฀Entries฀can฀be฀฀lte
based on (Start Date and End Date) and like Alert, Critical, Error, Filter By Date Event Category
Noti฀cation,฀Warning,฀Debug,฀Emergency฀and฀Information.
Download Event Logs: To download the event logs.
- 27 - Gigabyte Server Management Console
2-5-3 Audit Log
Audit Log page will display all the system events occurred in this device that has been already
con฀gured.฀
> Note Log Settings:฀Logs฀have฀to฀be฀con฀gured฀under฀Settings฀-> Advanced Log
Settings in order to display any entries.
To open the Event Log page, click Logs & Reports > Audit Log from the menu bar.
A sample screenshot of Audit Log page is shown below.
To view , click the Audit Log tab to view all audit events for this device. Audit Log
Download Event Logs: To download the event logs.
- 28 - Gigabyte Server Management Console
2-5-4 Video Log
To open the Video Log page, click Logs & Reports > Video Log from the menu bar. A sample
screenshot of Video Log page is shown below.
Note: Video Trigger Settings should be enabled, to display the Video Log page. Video Trigger
Settings can be configured under Settings -> Video Recording ->Auto Video Settings ->
Video Trigger Settings.
A sample screenshot of Video Log page is shown below.
Click on the Video Log entry to view the Video. A sample screenshot of Video Log - Video page is
shown below.
฀ Video฀will฀be฀allowed฀to฀play/download฀only฀if฀฀le฀size฀is฀lesser฀than฀40MB.฀Browsers฀
have various memory restrictions, due to this browser cannot store and process data
฀ greater฀than฀40MB฀(approximately).฀If฀฀le฀size฀is฀greater฀than฀40MB,฀user฀will฀be฀noti฀e
with a message to use Java player Application.
Gigabyte Server Management Console - 29 -
2-6 Settings
This group of pages allows you to access various configuration settings. A screenshot of
CongurationGroupmenuisshownbelow.
A detailed description of the Settings menu is given below.
2-6-1 Captured BSOD
This page displays a snapshot of the blue screen captured if the host system crashed since last
reboot. A screenshot of Captured BSOD is shown below.
: KVM service should be enabled to display the BSOD screen. KVM Service can be Note
 cong¬uredunderSettings->Services->KVM.
- 30 - Gigabyte Server Management Console
2-6-2 Date & Time
This฀฀eld฀is฀used฀to฀set฀the฀date฀and฀time฀on฀the฀BMC.฀ASample฀screenshot฀of฀Date฀&฀Time
shown below.
The฀Date฀&฀Time฀section฀consists฀of฀the฀following฀฀elds:
Configure Date & Time: Displays Time zone list containing the UTC offset along with the
locations and Navigational line to select the location which can be used to display the exact local
time.
Select Time Zone:฀This฀฀eld฀is฀used฀to฀set฀the฀date฀and฀time฀on฀the฀BMC.฀
Automatic Date & Time: To automatically synchronize Date and Time with the NTP Server.
Primary NTP Server:฀To฀con฀gure฀a฀primary฀NTP฀server฀to฀use฀when฀automatically฀setting฀the
date and time.
Secondary NTP Server:฀To฀con฀gure฀a฀secondary฀NTP฀server฀to฀use฀when฀automatically฀setting฀
the date and time.
Save:฀To฀save฀the฀con฀gured฀settings.
:If the timezone is selected as Manual Offset, the map selection will be disabled. Note
฀ The฀Time¬Zone฀settings฀will฀be฀re฀ected฀only฀after฀saving฀the฀settings.
Gigabyte Server Management Console - 31 -
Procedure
1. Select the location either using drop down or Map. Timezone
2. Enable Automatic Date & Time option to enable/disable the use of NTP servers to
automatically set the date and time.
•฀ In฀the฀Primary฀NTP฀Server฀and฀Secondary฀NTP฀Server฀฀elds,฀specify฀the฀NTP฀servers฀o
the device respectively.
: Note Secondary฀NTP฀server฀is฀optional฀฀eld.฀If฀the฀Primary฀NTP฀server฀is฀not฀working฀
฀ ฀ ฀ne,฀then฀the฀Secondary฀NTP฀Server฀will฀be฀used.
3. Click button to save the settings.Save
2-6-3 External User Services
LDAP/E-Directory Settings
The Lightweight Directory Access Protocol (LDAP)/E-Directory Settings is an application
protocol for querying and modifying data of directory services implemented in Internet Protocol (IP)
networks.
In Web GUI, LDAP is an Internet protocol that BMC can use to authenticate users. If you have
an฀LDAP฀ server฀ con฀gured฀on฀your฀ network,฀ you฀ can฀ use฀ it฀ as฀ an฀ easy฀ way฀ to฀ add,manag
and authenticate BMC users. This is done by passing login requests to your LDAP Server. This
means฀that฀there฀is฀no฀need฀to฀de฀ne฀an฀additional฀authentication฀mechanism,฀when฀using฀the
BMC. Since your existing LDAP Server keeps an authentication centralized, you will always know
who฀is฀accessing฀the฀network฀resources฀and฀can฀easily฀de฀ne฀the฀user฀or฀group-฀based฀policies
to control access.
To open External User Services page, click from the menu Settings > External User Services
bar. A sample screenshot of External User Services page is shown below.
- 32 - Gigabyte Server Management Console
To open LDAP/E-DIRECTORY Settings page, click Settings > External User Services >
LDAP/E-Directory Settings from the menu bar.
A sample screenshot of External User Services page is shown below.
The฀฀elds฀of฀LDAP/E-Directory฀Settings฀page฀are฀explained฀below.
General Settings:฀To฀con฀gure฀LDAP/E-Directory฀Settings.฀Options฀are฀Enable฀LDAP/E-Director
Authentication, IP Address, Port and Search base.
Role Groups: To add a new role group to the device. Alternatively, double click on a free slot to
add a role group.
Procedure
1. In the LDAP/E-Directory Settings page, click General Settings. A sample screenshot of
General LDAP Settings page is given below.
Gigabyte Server Management Console - 33 -
2. Click , to enable LDAP/E-Directory Settings.Enable LDAP/E-Directory Authentication
: Note Con฀gure฀proper฀port฀number,฀when฀SSL฀is฀enabled.
3. Select the Common Name Type as IP Address.
4. Enter฀the฀IP฀address฀of฀LDAP฀server฀in฀the฀Server฀Address฀฀eld.
: IP Address made of 4 numbers separated by dots as in ‘xxx.xxx.xxx.xxx’.Note
Each Number ranges from 0 to 255.
First Number must not be 0.
Supports IPv4 Address format and IPv6 Address format.
฀ ฀ Con฀gure฀FQDN฀address,฀when฀using฀StartTLS฀with฀FQDN.
5. Specify the LDAP Port in the Port ฀eld.
: Default Port is 389. For SSL connections, default port is 636. The Port value Note
ranges from 1 to 65535.
6. Specify the Bind DN that is used during bind operation, which authenticates the client to
the server.
: Bind DN is a string of 4 to 64 alpha-numeric characters.Note
It must start with an alphabetical character.
Special Symbols like dot(.), comma(,), hyphen(-), underscore(_), equal-to(=) are allowed.
Example: cn=manager, ou=login, dc=domain, dc=com
7. Enter the password in the Password฀฀eld.
: Password must be at least 1 character long.Note
Blank space is not allowed
฀ ฀ This฀฀eld฀will฀not฀allow฀more฀than฀48฀characters.
8. Enter the Search Base.฀The฀Search฀base฀allows฀the฀LDAP฀server฀to฀฀nd฀which฀part฀of฀
the external directory tree to be searched. The search base may be something equivalent
to the organization, group of external directory.
- 34 - Gigabyte Server Management Console
: Search base is a string of 4 to 63 alpha-numeric characters.Note
It must start with an alphabetical character.
Special Symbols like dot(.), comma(,), hyphen(-), underscore(_), equal-to(=) are allowed.
Example: ou-login, dc-domain, dc-com
9. Select฀Attribute฀of฀User฀Login฀to฀฀nd฀the฀LDAP/E-Directory฀server฀which฀attribute฀shou
be used to identify the user.
:It only supports cn or uid.Note
10. Select CA Certi฀cate File฀from฀the฀Browse฀฀eld฀to฀identify฀the฀certi฀cate฀of฀the฀trusted฀
CA certs.
11. Select the CA Certi฀cate File฀to฀฀nd฀the฀client฀certi฀cate฀฀lename.
12. Select Private Key฀to฀฀nd฀the฀client฀private฀key฀฀lename.
:Note All฀the฀3฀฀les฀are฀required,฀when฀StartTLS฀is฀enabled.
13. Click Save to the settings.save
To add a new Role Group
1. In the LDAP/E-Directory Settings page, click Role Groups and select a blank row.
2. Click Add Role Group or alternatively double click on the blank row to open the Add
Role group page as shown in the screenshot below.
3. In฀the฀Group฀Name฀฀eld,฀enter฀the฀name฀that฀identi฀es฀the฀role฀group.
Gigabyte Server Management Console - 35 -
: Role Group Name is a string of 255 alpha-numeric characters.Note
Special symbols hyphen and underscore are allowed.
4. In฀the฀Group฀Domain฀฀eld.฀Enter฀the฀Role฀Group฀Domain฀where฀the฀role฀group฀is฀locate
: Domain Name is a string of 4 to 64 alpha-numeric characters.Note
It must start with an alphabetical character.
Special Symbols like dot(.), comma(,), hyphen(-), underscore(_), equal-to(=) are allowed.
Example: cn=manager, ou=login, dc=domain, dc=com
5. In฀the฀ Group฀ Privilege฀ ฀eld,enter฀ the฀ level฀ of฀ privilege฀ (User,฀Administrator,฀Operato
None) to assign to this role group.
6. Select one or both of the required options
•฀ KVM Access
•฀ VMedia Access
7. Click to save the new role group and return to the Role Group List.Save
Active Directory Settings
An active directory is a directory structure used on Microsoft Windows based computers and
servers to store information and data about networks and domains. An active directory (sometimes
referred to as AD) does a variety of functions including the ability to provide information on
objects. It also helps to organize these objects for easy retrieval and access, allows access by
end users and administrators and allows the administrator to set security up for the directory.
Active฀Directory฀allows฀you฀to฀con฀gure฀the฀Active฀Directory฀Server฀Settings.฀The฀displayed฀ta
shows฀any฀con฀gured฀Role฀Groups฀and฀the฀ available฀slots.฀You฀can฀modify,฀add฀or฀ delete฀ro
groups from here. Group domain can be the AD domain or a trusted domain. Group Name should
correspond to the name of an actual AD group.
Note: To view the page, you must be at least a User and to modify or add a group, you must be
an Administrator.
- 36 - Gigabyte Server Management Console
To open Active Directory Settings page, click Settings > External User Settings > Active
Directory from the menu bar. A sample screenshot of Active Directory Settings page is shown
below.
The฀฀elds฀of฀Active฀Directory฀page฀are฀explained฀below.
General Settings:฀This฀option฀ is฀used฀ to฀con฀gure฀Active฀Directory฀ General฀Settings.฀ Options
are Enable Active Directory Authentication, Secret User Name, Secret Password, User Domain
name, and up to three Domain Controller Server Addresses.
Role Groups: To add a new role group to the device. Alternatively, double click on a free slot to
add a role group.
Gigabyte Server Management Console - 37 -
Procedure
Entering the details in General Active Directory Settings page:
1. Click on to open the General Active Directory Settings page.General Settings
2. In the Active Directory Settings page, check or uncheck the Enable Active directory
Authentication check box to enable or disable Active Directory Authentication
respectively.
:If you have enabled. Active Directory Authentication, enter the required information Note
to access the Active Directory server.
3. Specify the Secret user name and password in the Secret User Name and Secret
Password฀฀elds฀respectively.
: Secret username/password for AD is not mandatory. When secret username & Note
password is empty, Authentication fails will be always treated as Invalid Password error.
For Invalid Password error PAM will not try other Authentication Methods. So it is
recommended to keep AD in the last location in PAM order.
User Name is a string of 1 to 64 alpha-numeric characters.
It must start with an alphabetical character.
It is case-sensitive.
Special characters like comma, period, colon, semicolon, slash, backslash, square
brackets,
Blank space is not allowed, angle brackets, pipe, equal, plus, asterisk, question mark,
- 38 - Gigabyte Server Management Console
ampersand, double quotes, space are not allowed.
Password must be at least 6 character long and will not allow more than 127 characters.
4. Specify฀the฀Domain฀Name฀for฀the฀user฀in฀the฀User฀Domain฀Name฀฀eld.฀E.g.฀MyDomai
com
5. Con฀gure฀ IP฀ addresses฀ in฀ Domain฀ Controller Server Address1, Domain Controller
Server Address2 and Domain Controller Server Address3
: IP address of Active Directory server: At least one Domain Controller Server Note
฀ Address฀must฀be฀con฀gured.฀IP฀Address฀made฀of฀4฀numbers฀separated฀by฀dots฀as฀in฀
“xxx.xxx.xxx.xxx”.
Each number ranges from 0 to 255.
First number must not be 0.
Domain Controller Server Addresses will supports IPv4 Address format and IPv6
Address format.
6. Click Save to the entered settings and return to Active Directory Settings page.save
Role Groups
To open Role Group page, click Settings > External User Settings > Active Directory > Role
Groups from the menu bar. A sample screenshot of Role Groups page is shown below.
The฀฀elds฀of฀Role฀Group฀page฀are฀explained฀below.
Role Group Name:฀The฀name฀that฀identi฀es฀the฀role฀group฀in฀the฀Active฀Directory.
Role Group Name is a string of 64 alpha-numeric characters.Note:
Special symbols hyphen and underscore are allowed.
Gigabyte Server Management Console - 39 -
Group Name:฀This฀name฀identi฀es฀the฀role฀group฀in฀Active฀Directory.
Role Group Name is a string of 64 alpha-numeric characters.Note:
Special symbols hyphen and underscore are allowed.
Group Domain: The domain where the role group is located.
Domain Name is a string of 255 alpha-numeric characters.Note:
Special symbols hyphen, underscore and dot are allowed.
Group Privilege: The level of privilege to assign to this role group.
KVM Access: To provide access to KVM for AD authenticated role group user.
VMedia Access: To provide access to VMedia for AD authenticated role group user.
To add a new Role Group
1. In the Active Directory Settings page, select a Role Group and click Add Role Group or
alternatively double click on the blank row to open the Add Role group page as shown in
the screenshot below.
2. In the Group Name field, enter the name that identifies the role group in the Active
Directory.
: Role Group Name is a string of 64 alpha-numeric characters.Note
Special symbols hyphen and underscore are allowed.
3. In฀the฀Group฀Domain฀฀eld,฀enter฀the฀domain฀where฀the฀role฀group฀is฀located.
: Domain Name is a string of 255 alpha-numeric characters. - Special symbols Note
hyphen, underscore and dot are allowed.
4. In the Group Privilege฀฀eld,฀enter฀the฀level฀of฀privilege฀to฀assign฀to฀this฀role฀group.
- 40 - Gigabyte Server Management Console
5. Select the required options
•฀ KVM Access
•฀ VMedia Access
6. Click to add the new role group and return to the Role Group List.Save
To Delete a Role Group
1. In the Page, select the row that you wish to deleteRole Groups
2. Click Delete Role Group.
RADIUS Settings
RADIUS is a modular, high performance and feature-rich RADIUS suite including server, clients,
development libraries and numerous additional RADIUS related utilities.
In Web GUI, this page is used to set the RADIUS Authentication.
To open RADIUS Settings page, click Settings > External User Settings > RADIUS Settings
from the menu bar. A sample screenshot of RADIUS Settings page is shown below.
The฀฀elds฀of฀General฀RADIUS฀Settings฀page฀are฀explained฀below.
Enable RADIUS Authentication: Option to enable/disable RADIUS authentication.
Server Address: The IP address of RADIUS server.
: IP Address (Both IPv4 and IPv6 format).Note
฀ FQDN฀(Fully฀Quali฀ed฀Domain฀Name)฀format.
Port: The RADIUS Port number.
: Default Port is 1812.Note
Port value ranges from 1 to 65535.
Secret: The Authentication Secret for RADIUS server.
Note:฀This฀฀eld฀will฀not฀allow฀more฀than฀31฀characters.
Secret must be at least 4 characters long.
Gigabyte Server Management Console - 41 -
Blank space is not allowed.
Enable KVM Access:฀This฀฀eld฀provides฀access฀to฀KVM฀for฀RADIUS฀authenticated฀users.
Enable VMedia Access:฀This฀฀eld฀provides฀access฀to฀VMedia฀for฀RADIUS฀authenticated฀users.
Save:฀To฀save฀the฀con฀gured฀settings.
Procedure
1. Enable the check box to authenticate the RADIUS.RADIUS Authentication
2. Click Advanced RADIUS Settings. This opens the Radius Authorization window as
shown below.
Note:฀For฀Authorization฀Purpose,฀con฀gure฀the฀Radius฀user฀with฀Vendor฀Speci฀c฀฀
Attribute in Server side.
Example: 1
testadmin Auth-Type: =PAP, Cleartext-Password:=”admin”
฀ Auth-Type:฀=PAP,฀Vendor-Speci฀c=฀”H=4฀”
Example: 2
test operator Auth-Type: = PAP, Cleartext-Password:= “operator”
฀ Auth-Type:฀=PAP,฀Vendor-Speci฀c=฀”H=3฀”
฀ If฀you฀change฀the฀Vendor-Speci฀c฀value฀in฀server฀then฀you฀should฀change฀the฀same฀฀
values in this page.
3. Click to save the changes made.Save
Gigabyte Server Management Console - 42 -
2-6-4 KVM Mouse Settings
In BMC Web GUI, Redirection Console handles mouse emulation from local window to remote
screenin eitherof threemethods.Userhasto beanAdministratortocongurethisoption.To
view the Supported Operating Systems for Mouse Mode, click Mouse Mode.
To open KVM Mouse setting page, click from the menu bar. Settings >KVM Mouse Setting
A sample screenshot of KVM Mouse Settings page is shown below.
TheeldsofKVMMouseSettingspageareexplainedbelow.
Relative Positioning (Linux): Relative mode sends the calculated relative mouse position
displacement to the server.
Absolute Positioning (Windows): The absolute position of the local mouse is sent to the server.
Other Mode (SLES-11 OS Installation): To have the calculated displacement from the local mouse
in the center position sent to the server.
Save: To save the current changes.
Procedure
1. Choose either of the following as your requirement:
• Set mode to Absolute
: Applicable for all Windows versions, versions above RHEL6, and versions above Note
FC14
• Set mode to Relative
: Applicable for all Linux versions, versions less than RHEL6, and versions less Note
than FC14
• Mode to Other Mode
Gigabyte Server Management Console - 43 -
: Recommended for SLES-11 OS InstallationNote
2. Click button to save the changes made.Save
- 44 - Gigabyte Server Management Console
2-6-5 Log Settings
In BMC Web GUI, System and Audit log page displays a list of system logs and audit logs
occurred in this device.
To open Log Settings page, click Settings > Log Settings from the menu bar. A sample
screenshot of Log Settings page is shown below.
TheeldsofLogSettingspageareexplainedbelow.
SEL Settings Policy
To open SEL Settings Policy page, click Settings > Log Settings > SEL Settings Policy from
the menu bar. A sample screenshot of SEL Settings Policy page is shown below.
- 46 - Gigabyte Server Management Console
Enable Audit Log: To enable or disable the audit log.
Save: To save the current changes.
Procedure
1. In the System Logeld,enableordisabletheoption.
2. Select the Log type: Local Log or Remote Log.
3. IfLocallogisselected, enterthelesizein the eldandrotatecountintheFile Size
Rotate Counteld.
Note:IfRemotelogisselected,theeldslesizeandrotatecountneednotbe
mentioned.
4. If remote log is selected specify the of the remote server, where the Server Address
system events are logged.
5. In the option as desired.Audit Log Enableeld,checkoruncheckthe
6. Click to save the changes.Save
Steps to congure the remote server to enable syslogging
: This example uses FC13 as the remote machine to log syslog.Note
On FC machine, disable the following lines for UDP in /etc/rsyslog.conf:
1. MODLOAD imudp
2. UDPSERVER 514
Gigabyte Server Management Console - 47 -
2-6-6 Media Redirection Settings
Thispageisusedtocongurethe mediaintoBMC forredirection.ToopenMediaRedirection
page, click from the menu bar.Settings > Media Redirection Settings
A sample screenshot of Media Redirection page is shown below.
- 48 - Gigabyte Server Management Console
TheeldsofMediaRedirectionpageareexplainedbelow.
• General Settings
• VMedia Instance Settings
• Remote Session
• Active Redirections
General Settings
ThisoptionisusedtocongureGeneralMediaSettings.
To open General Media Settings section, click > General Settings > Media Redirection Settings
Settings.
Remote Media Support: To enable or disable Remote Media support, check/uncheck the ‘Enable
check box.
If it is selected, then the following Remote Media types will be displayed.
• Mount CD/DVD
• Mount Harddisk
Onselectingtheindividualmediatypes,itsrespectivecongurationswillbedisplayed.Youcan
conguredifferentsettings for different Remote Media types.Asample screenshot of General
Settings page is shown below.
Gigabyte Server Management Console - 49 -
: You can also select all the media types simultaneously.Note
Server Address for CD/DVD Images: Displays the address of the server where the
remote media images are stored.
Same settings for Harddisk Images: Enable/Disable to select same media type data
congurationsforalltheremotemediatypes.
Mount Harddisk: Enable/Disable to Mount Harddisk.
Server Address for Harddisk Images: Address of the server where the remote media images
are stored.
Path in server: Source path to the remote media images.
Share Type for Harddisk: To Select Share Type for Floppy.
Domain Name, Username, and Password: If share Type is Samba(CIFS), then enter user
credentials to authenticate on the server.
VMedia Instance Settings
ThispageisusedtocongureVirtualMediadevicesettings.ToopenVMediaInstanceSettings
page, click from the menu Settings > Media Redirection Settings > VMedia Instance Settings
bar.
A sample screenshot of VMedia Instance Settings page is shown below.
- 50 - Gigabyte Server Management Console
Thefollowingeldsaredisplayedinthispage:
CD/DVD device instances: The number of CD/DVD devices supported for Virtual Media
redirection.
Harddisk instances: The number of harddisk devices supported for Virtual Media redirection.
Remote KVM CD/DVD device instances: The number of CD/DVD devices supported for KVM
Virtual Media redirection.
Remote KVM Hard disk instances: The number of Hard disk devices supported for KVM Virtual
Media redirection.
Emulate SD Media as USB disk to Host: To emulate SD Media on BMC as a USB device to
Host Server.
Power Save Mode: To enable or disable the virtual USB devices visibility in the host. If this option
is enabled, Virtual media devices will be connected to the Host machine only at the instance
launching KVM session. If this option is disabled, Virtual media devices will remain connected to
the host machine all the time irrespective of KVM session status.
Save:Tosavetheconguredsettings.
: Note VirtualMediacongurationchangeswillrestartallthemediaservices.So
 congurationchangeswillbeblockedwhenanyactivemediaredirectionispresent.
Procedure
1. Select the number of Floppy devices, CD/DVD devices, Harddisk devices and Remote
KVM Floppy, CD/DVD and Hard disk Devices from the respective drop-down list.
: Maximum of four devices can be added in Floppy, CD/DVD and Harddisk drives.Note
Gigabyte Server Management Console - 51 -
2. Select the option to enable/disable the SD Emulate SD Media as USB disk to Host
card support in the host.
3. Check the option to enable/disable the Virtual USB devices visibility Power Save Mode
in the host.
4. Click Save to save the changes made else click Reset to reset the previously saved
values.
: When KVM is launched from Standalone Application, if there are two device Note
panels for each device, and when you click the Connect button, then the redirected
device panel will be disabled.
Unmounting device will make the driver disconnect device when using . Auto Attach
Hence, when unmounting one USB key, the other USB key will be disconnected and
then reconnected.
Remote Session
InBMCWeb,thispageisusedtocongureRemoteSessioncongurationsettings.“KVMSingle
Port Application” is enabled by default. On disabling, “KVM Single Port Application”, “Encrypt
H5Viewer KVM packets” will be enabled by default. On enabling “KVM Single Port Application”,
“Encrypt H5Viewer KVM packets” will be disabled if it is enabled already.
To open Remote Session page, click Settings > Media Redirection Settings > Remote
Session from the menu bar.
A sample screenshot of Remote Session page is shown below.
- 52 - Gigabyte Server Management Console
TheeldsofCongureRemoteSessionpageareexplainedbelow.
KVM Single Port Application: To Enable/Disable single port support by runtime. On changing
thisconguration,KVMandVMediaSessionswillberestarted.Ifthissupportisenabled,KVM
session will not use its dedicated port whereas both Web and KVM sessions will be established
only via Web Port. If this support is disabled, KVM and Web sessions will use their own dedicated
ports respectively.
Enable KVM Encryption: To Enable/Disable Enable KVM Encryption for the next redirection
session. If KVM Encryption is enabled, the KVM session will use the Secure port which has been
conguredinSettings->ServicesPage.
Note: If “Allow Non-Secure communication for KVM/Media” in the PRJ option is enabled,
then KVM/Media can use non-secure communication. i.e. The KVM or Media Encryption
will be able to disable.
If KVM Encryption is disabled, the KVM session will use the Non-Secure port which has
 beenconguredinSettings->Services Page.
: This option is disabled if Single Port is enabled.Note
Keyboard Language: This option is used to select the keyboard supported languages.
Retry Count: This option is used to retry the redirection session for certain number of attempts.
Retry Time Interval(Seconds): This option is used to give time interval for each attempts.
Server Monitor OFF Feature Status: To enable/disable Server Monitor OFF. If this option is
enabled, you can Lock or Unlock the Local host monitor from the remote KVM window. If this
option is disabled, you cannot Lock or Unlock the Local host monitor from the remote KVM
window.
Automatically OFF Server Monitor, When KVM Launches: To enable/disable Automatically
OFF Server Monitor, When KVM Launches.
Save: To save the current changes.
: It will automatically close the existing remote redirection either KVM or Virtual Note
media sessions on Single Port enable/Disable.
: Installation of Operating System on the servers via BMC CD ISO image over Note
remote KVM may take 1 to 2 hours.
Procedure
1. Check or uncheck the KVM Single Port Application option to enable Single Port
Application support in BMC.
2. Choose the from the list of keyboard supported languages.Keyboard Language
3. Enter a value in the Retry Count eldto set the number of attemptsfor retrying the
redirection session.
4. Enter a value in the Retry Time Interval (Seconds)eldtogivetimeintervalforeach
attempts.
5. Check the check box to enable Local Monitor ON/Server Monitor OFF Feature Status
- 53 - Gigabyte Server Management Console
OFF command during runtime.
6. , Check the Automatically OFF Server Monitor When KVM Launches check box to
automatically Lock the local monitor during H5Viewer launch.
7. Click to save the current changes.Save
Active Redirections
This page displays a list of Media which are being redirected currently. It shows current status
and other basic information about the Media.
Thefollowingeldsaredisplayedinthispage.
Media Type: The type Media devices (CD/DVD) supported for Active Redirections.
Media instances: The number of Media devices supported for Active Redirections.
Client Type: The type Media devices (CD/DVD) supported for Active Redirections.
Image Name: The name of Media devices supported image for Active Redirections.
Redirection Status: The status Media for Active Redirections.
Client IP: The IP of the connected Media devices (CD/DVD) supported for Active Redirections.
: Note Local/Remote Media connection will use loopback socket for communication. So
‘~’ symbol will be displayed for loopback ip(127.0.0.1 (or) ::1 ) in media session information
page.
Gigabyte Server Management Console - 54 -
2-6-7 Network Settings
The Network Settings page is used to configure the network settings for the available LAN
channels. It also allows users to manage the DNS settings or configure Network Controller
Sideband Interface of a device. To open the Network Settings page, click Settings > Network
Settings from the menu bar.
- 55 - Gigabyte Server Management Console
Network IP Settings
To open Network IP Settings page, click Settings > Network Settings > Network IP Settings
from the menu bar. A sample screenshot of Network IP Settings page is shown below.
TheeldsofNetworkIPSettingspageareexplainedbelow.
Enable LAN: To enable or disable the LAN Settings.
LAN Interface: Lists the LAN interfaces.
MAC Address:ThiselddisplaystheMACAddressofthedevice.Thisisareadonlyeld.
Enable IPv4: This option is to enable/disable the IPv4 settings in the device.
Enable IPv4 DHCP: This option is to enable IPv4 DHCP support for the selected interface.
IPv4 Address, IPv4 Subnet Mask, and IPv4 Default Gateway:Theseeldsareforspecifying
thestaticIPv4address,SubnetMaskandDefaultGatewaytobeconguredtothedevice.
: IP Address made of 4 numbers separated by dots as in “xxx.xxx.xxx.xxx”.Note
Each Number ranges from 0 to 255.
First Number must not be 0.
Enable IPv6:ToEnable/DisabletheIPv6congurationsettings.
Enable IPv6 DHCP:ToEnable/DisabletheIPv6settingsinthedevice.Itdynamicallycongures
IPv6addressusingDHCP(DynamicHostCongurationProtocol).
IPv6 Index:TospecifyastaticIPv6Indextobeconguredtothedevice.E.g.:0
IPv6 Address:TospecifyastaticIPv6addresstobeconguredtothedevice.E.g.:2004::2010
Gigabyte Server Management Console - 56 -
Subnet Prex length:TospecifythesubnetprexlengthfortheIPv6settings.
: Value ranges from 0 to 128.Note
Default Gateway: Specify v6 default gateway for the IPv6 settings.
Note: IfcorefeatureIPV6_COMPLIANCEisenabled,theIPV6defaultGatewayeldwill
not be displayed.
Enable VLAN: To enable/disable the VLAN support for selected interface.
VLAN ID:TheIdenticationforVLANconguration.
: Value ranges from 2 to 4094.Note
VLAN Priority:ThepriorityforVLANconguration.
: Note
Value ranges from 0 to 7.
7 is the highest priority for VLAN.
Save: To save the entries.
Procedure
1. Check to enable LAN support for the selected interface.Enable LAN
2. Select the LAN Interfacetobecongured.
3. Check Enable IPv4 to enable IPv4 support for the selected interface.
4. Check Enable IPv4 DHCPtodynamicallycongureIPv4addressusingDHCP.
5. Iftheeld is disabled, enterthe IPv4 Address, IPv4 Subnet Mask and IPv4 Default
Gateway intherespectiveelds.
6. .InIPv6Conguration,ifyouwishtoenabletheIPv6settings,checkEnable IPv6
7. If the IPv6 setting is enabled, enable or disable the option .Enable IPv6 DHCP
8. Iftheeldisdisabled,entertheIPv6 Address, Subnet Prex length and in IPv6 Index
thegiveneld.
9. .InVLANConguration,ifyouwishtoenabletheVLANsettings,checkEnable LAN
10. Enter the VLAN IDinthespeciedeld.
11. 11. Enter the VLAN Priorityinthespeciedeld.
12. Click to save the entries.Save
- 57 - Gigabyte Server Management Console
DNS Conguration
The Domain Name System (DNS) is a distributed hierarchical naming system for computers,
services, or any resource connected to the Internet or a private network. It associates the
information with domain names assigned to each of the participants. Most importantly, it
translatesdomainnamesmeaningfultohumansintothenumerical(binary)identiersassociated
with networking equipment for the purpose of locating and addressing these devices worldwide.
The DNS Server settings page is used to manage the DNS settings of a device.
To open DNS Server Settings page, click Settings > Network Settings > DNS Conguration
fromthemenubar.AsamplescreenshotofDNSCongurationpageisshownbelow.
Gigabyte Server Management Console - 58 -
Domain Name Service Conguration
DNS Enabled:Toenable/disablealltheDNSServiceCongurations.
mDNS Enable:Toenable/disablethemDNSSupportCongurations.
Host Name Settings: Choose either Automatic or Manual settings.
Host Name: It displays host name of the device. If the Host setting is chosen as Manual, then
specify the host name of the device.
: Value ranges from 1 to 64 alpha-numeric characters.Note
Special characters ‘-’(hyphen) and ‘_’(underscore) are allowed.
It must not start or end with a ‘-’(hyphen). IE browsers won't work correctly if any part of
the host name contain underscore (_)character.
BMC Registration Settings
BMC Interface: Options to register the BMC through the Interfaces (eth0&eth1).
Register BMC: To register BMC through registration method.
Registration Method
Options to register the BMC are through or or .NS Update DHCP Client FQDN Hostname
TSIG Conguration
Both: Check this option to modify TSIG authentication for both interfaces.
Eth 0&1:
TSIG Authentication Enabled: Check this box to enable TSIG authentication while
registeringDNSviansupdate.SeparateTSIGlescanbeuploadedforeachLAN
interface.
Current TSIG Private File:TheinformationofCurrentTSIGprivatelealongwith
its uploaded date/time will be displayed (readonly).
New TSIG Private File:BrowseandnavigatetotheTSIGprivatele.
Note:TSIGleshouldbeofprivatetype.
Domain Setting: Select whether the domain interface will be configured manually or
automatically.
Automatic-IfyouSelectAutomatic,theDomainNamecannotbeconguredasit
willbedoneautomatically.Theeldwillbedisabled.
Manual - If the Domain setting is chosen as Manual, then specify the domain name
of the device.
: If you select “Automatic” it displays the Domain Interface option. If Note
you select “Manual” it displays “Domain name”.
Domain Name: It displays the domain name of the device.
Domain Name Server Setting
Automatic - If you select Automatic “DNS Interface” option should be explained.
Manual -SpecifytheDNS(DomainNameSystem)serveraddresstobeconguredfortheBMC.
- 59 - Gigabyte Server Management Console
IP Priority:
• If IP Priority is IPv4, it will have 2 IPv4 DNS servers and 1 IPv6 DNS server.
• If IP Priority is IPv6, it will have 2 IPv6 DNS servers and 1 IPv4 DNS server.
Note:ThisisnotapplicableforManualconguration.
DNS Server 1, 2 & 3
TospecifytheDNS(DomainNameSystem)serveraddresstobeconguredfortheBMC.
IPv4 Addresses should be given in dotted decimal representation.Note:
IPv6 Addresses are supported and must be global unicast addresses.
DNS Server Address will support the following:
• IPv4 Address format.
• IPv6 Address format.
Save: To save the current changes.
Procedure
1. InDomainNameServiceConguration,EnableDNSService.
• toenablealltheDNSServiceCongurations.Check the option DNS Enabled
2. Choose the Host Name Setting either Automatic or Manual.
If you choose Automatic, you need not enter the Host Name and if you choose Note:
Manual, you need to enter the Host Name.
3. Enter the Host NameinthegiveneldifyouhavechosenManualConguration.
4. Under Register BMC, choose the BMC’s network port to register with DNS settings.
Check option to register with DNS settings.Register BMC
Nsupdate - Choose Nsupdate option to register with DNS server using nsupdate
application.
DHCP Client FQDN - Choose DHCP Client FQDN option to register with DNS
Server using DHCP option 81.
Hostname - Choose Hostname option to register with DNS server using DHCP
option 12.
Hostname option should be selected, if the DHCP client FQDN option is not Note:
supported by DHCP server.
5. Check option to modify TSIG authentication for both interfaces (eth0&1).Both
6. In Eth 0&1 TSIG Conguration, Check TSIG Authentication Enabled option to enable/
disable TSIG authentication while registering DNS via nsupdate.
• ThecurrentlenamewillbedisplayedinCurrentTSIGPrivateleinfoeld.
• Toviewanewone,clickNewTSIGprivateletobrowseandnavigatetotheTSIG
privatele.
7. In the Domain Settings,
• Select the domain settings (Automatic or Manual).
• EntertheDomainNameinthegiveneldiftheoption“Manual”isbeingselectedin
domainsettingseld.
- 60 - Gigabyte Server Management Console
8. In Domain Name Server Setting,
• Select the DNS Name Server Setting.
• Choose the IP Priority, either IPv4 or IPv6.
• Enter the DNS Server address.
9. In DNS Server1, DNS Server2 and DNS Server3, enter the server addresses to be
conguredfortheBMC.
10. Click to save the entries.Save
Gigabyte Server Management Console - 62 -
NVMe-MI Vital Product Data
On selecting any particular NVMe SSD, the corresponding SSD's Product Information will be
displayed. It displays detailed information like IPMI Version, Product Name, Part Model, Product
Version etc.. of the NVMe SSD. On Click of 'Multi Record Informaion' tab NVMe MultiRecord and
NVMe PCIe Port MultiRecord will be displayed.
Gigabyte Server Management Console - 63 -
2-6-9 PAM Order Settings
ThispageisusedtocongurethePAMorderingforuserauthenticationintotheBMC.
To open PAM Ordering page, click Settings > PAM Order Settings from the menu bar. A sample
screenshot of PAM Order page is shown below:
TheeldsofSetttings > PAM Ordering page are explained below.
PAM Module: It shows the list of available PAM modules supported in BMC.
It is recommended to not to keep same username for different PAM modules.Note:
If Authentication fails, the reason of fail could be invalid User or Invalid Password.
If Radius Authentication fails, we can't differentiate whether it is invalid user or invalid
password. So it is always treated as Invalid username error and PAM will try other
Authentication Methods.
If AD contains secret username & password as empty, Authentication fails will be always
treated as Invalid Password error. For Invalid Password error PAM will not try other
Authentication Methods. So it is recommended to keep AD in the last location in PAM
order.
Procedure
1. Select the required PAM module and click and drag the required PAM module. It can be
moved UP or DOWN to change its arrangement order.
2. Click to save any changes made.Save
Note: Wheneverthecongurationismodied,thewebserverwillberestarted 
automatically. Logged-in session will be logged out.
- 68 - Gigabyte Server Management Console
Alert Policies
This฀page฀is฀used฀to฀con฀gure฀the฀Alert฀Policy฀for฀the฀PEF฀con฀guration.฀You฀can฀add,฀delete฀
modify an entry in this page.
The฀฀elds฀of฀Platform฀Event฀Filter฀-฀Alert฀Policies฀section฀are฀explained฀below.
Policy Group Number:฀Displays฀the฀Policy฀number฀of฀the฀con฀guration.
Enable this alert: To enable or disable the policy settings.
Policy Action: To choose any one of the Policy set values (0-5) from the list.
0 - Always send alert to this destination.
1 - If alert to previous destination was successful, do not send alert to this destination. Proceed to
next entry in this policy set.
2 - If alert to previous destination was successful, do not send alert to this destination. Do not
process any more entries in this policy set.
3 - If alert to previous destination was successful, do not send alert to this destination. Proceed to
next entry in this policy set that is to a different channel.
4 - If alert to previous destination was successful, do not send alert to this destination. Proceed to
next entry in this policy set that is to a different destination type.
LAN Channel: To choose a particular channel from the available channel list.
Destination฀Selector:฀To฀choose฀a฀particular฀destination฀from฀the฀con฀gured฀destination฀list.
Note: Settings->Platform Event Filters LAN฀Destination฀has฀to฀be฀con฀gured฀-฀under฀
>LAN Destinations.
Event Speci฀c Alert String:฀To฀specify฀an฀event-speci฀c฀Alert฀String.
Alert String Key: To specify which string is to be sent for this Alert Policy entry.
Save: To save the Alert Policies entries.
Delete:฀To฀delete฀the฀selected฀con฀gured฀Alert฀Policy.
Procedure
1. In฀ the฀Alert฀ PoliciesSection,฀ select฀ the฀slot฀ for฀whichyou฀ haveto฀con฀gurethe฀Ale
policy. That is, In the , if you have chosen Alert Policy Group Number Alert Policies page
as฀4,฀you฀have฀to฀con฀gure฀the฀4th฀slot฀(the฀slot฀with฀Policy฀Number฀4)฀in฀the฀Alert฀Pol
Tab.
- 70 - Gigabyte Server Management Console
LAN Destinations
This฀page฀is฀used฀to฀con฀gure฀the฀LAN฀destination฀of฀PEF฀con฀guration.฀A฀sample฀screenshot฀o
LAN Destination page is given below.
The฀฀elds฀of฀Platform฀Event฀Filters฀-฀LAN฀Destinations฀are฀explained฀below.
Select฀any฀empty฀slot฀to฀con฀gure฀LAN฀Destinations.
Select the LAN Channel: To select the LAN Channel number
LAN Channel: Displays LAN Channel Number for the selected slot (read-only).
LAN Destination: Displays ID for setting Destination Selector of Alert Policy (read-only).
Destination Type: Destination type can be either an SNMP Trap or an E-mail alert. For E-mail
alerts,฀the฀four฀ ฀elds฀-฀SNMP฀ Destination฀Address,฀BMC฀User฀ Name,฀Email฀subject฀and฀Em
message฀needs฀to฀be฀฀lled.฀The฀SMTPserver฀information฀also฀has฀to฀be฀added฀-฀under฀Settings
->SMTP Settings.฀For฀SNMP฀Trap,฀only฀the฀SNMP฀Destination฀Address฀has฀to฀be฀฀lled.
Gigabyte Server Management Console - 79 -
Procedure
1. Select the from the drop-down list.LAN Interface
2. Enter the Sender Email ID฀in฀the฀speci฀ed฀฀eld.
3. Check option to enable SMTP support for the BMC.Primary SMTP Support
4. Enter the Machine Name of the SMTP Server in the .Primary Server Name
- Machine Name is a string of maximum 15 alpha-numeric characters.Note:
Space, special characters are not allowed.
5. Enter IP address of the SMTP Server in the Primary Server IP฀฀eld.฀It฀is฀a฀mandatory฀
฀eld.
6. Enter the Primary SMTP Port฀in฀the฀speci฀ed฀฀eld.
7. Enter the Primary Secure SMTP Port in฀the฀speci฀ed฀฀eld.
8. Enable the check box if you want to authenticate SMTP Primary SMTP Authentication
Server.
9. Enter your and Primary User name Primary Password฀in฀the฀respective฀฀elds.
10. Enable the check box Primary SMTP SSLTLS Enable to send data through secure Port.
If this option is selected, STARTTLS option and Normal Port will be hidden.Note:
11. Check the option to enable Secondary SMTP support for the Secondary SMTP Support
BMC.
12. Enter the and Secondary Server Name, Secondary Server IP, Secondary SMTP Port
Secure Port values฀in฀the฀respective฀฀elds.
13. Enable the check box if you want to authenticate SMTP SMTP Server Authentication
Server.
14. Enter your and Secondary User name Password in฀the฀respective฀฀elds.
15. Enable the check box Secondary SMTP SSLTLS to send data through secure Port.
If this option is selected, STARTTLS option and Normal Port will be hidden.Note:
16. Click to save the entered details.Save
- 82 - Gigabyte Server Management Console
City or Locality(L): City or Locality of the organization (mandatory).
•฀ Maximum length of 128 characters.
•฀ It is a string of alpha-numeric characters.
•฀ Special characters ‘#’ and ‘$’ are not allowed.
State or Province(ST): State or Province of the organization (mandatory).
•฀ Maximum length of 64 characters.
•฀ It is a string of alpha-numeric characters.
•฀ Special characters ‘#’ and ‘$’ are not allowed.
Country(C): Country code of the organization (mandatory).
•฀ Only two characters are allowed.
•฀ Special characters are not allowed.
Email Address: E-mail Address of the organization (mandatory).
Valid for:฀Validity฀of฀the฀certi฀cate.
•฀ Value ranges from 1 to 3650 days.
Key Length:฀The฀key฀length฀bit฀value฀of฀the฀certi฀cate.
Save:฀To฀generate฀the฀new฀SSL฀certi฀cate.
Note: HTTPs฀service฀will฀get฀restarted,฀to฀use฀the฀newly฀generated฀SSL฀certi฀cate.
- 84 - Gigabyte Server Management Console
Procedure
1. Click฀the฀Upload฀SSL฀Certi฀cate฀tab,฀Browse฀the฀New฀Certi฀cate฀and฀New฀Private฀key.
2. Click฀Upload฀to฀upload฀the฀new฀certi฀cate฀and฀private฀key.
3. In฀Generate฀SSL฀Certi฀cate,฀enter฀the฀following฀details฀in฀the฀respective฀฀elds:
•฀ for฀which฀the฀certi฀cate฀is฀to฀be฀generated.The Common Name
•฀ ฀for฀which฀the฀certi฀cate฀is฀to฀be฀generated.The Organization
•฀ name฀for฀which฀certi฀cate฀to฀be฀generated.The Organization Unit
•฀ The of the organizationCity or Locality
•฀ The of the organizationState or Province
•฀ The of the organizationCountry
•฀ The of the organization.Email address
•฀ The฀number฀of฀days฀the฀certi฀cate฀will฀be฀valid฀in฀the฀Valid For฀฀eld.
4. Choose the Key Length฀bit฀value฀of฀the฀certi฀cate
5. Click Save฀to฀generate฀the฀certi฀cate.
6. Click View SSLCerti฀cate฀ tab฀ toview฀ the uploaded฀SSLcerti฀cate in฀ user readable
format.
Note: Once฀you฀Upload/Generate฀the฀certi฀cates,฀only฀HTTPs฀service฀will฀get฀restarted.
You can now access your Web securely using the following format in your IP Address
฀ ฀eld฀from฀your฀Internet฀browser:฀https://<your฀BMC's฀IP฀address฀here>
For example, if your BMC's IP address is 192.168.0.30, enter the following:
https://192.168.030
Please฀note฀the฀<s>฀after .฀You฀must฀accept฀the฀certi฀cate฀before฀you฀are฀able฀to฀ <http>
access your Web.
- 89 - Gigabyte Server Management Console
IP Address Firewall Rules
Click page. A sample screenshot of IP Firewall Rules page is shown below. IP Firewall Rules
The฀฀elds฀of฀IP Address Firewall tab are explained below.
To View Existing IP Rules or a range of IP Addresses
Click Settings > System Firewall > IP Address Firewall Rules > Existing IP Rules. A blank
page will be opened if you did not add anything in “Add IP Rule”. If any rule is added, then the
added rule will be listed in “Existing IP Rules” page.
A sample screenshot of Existing IP Rules page is shown below.
The Existing IP Rules page allows you to remove any particular Existing IP Rules.
Procedures
1. Select the Existing IP Rules you want to remove.
2. Click on Delete to remove the selected Existing IP Rules.
Gigabyte Server Management Console - 94 -
Procedure to add Port/Range of ports
1. To add a new range of Port address, click the Add button
2. In the for Port window, enter the port number or a range of port numbers Add new rule
in the Port Single (or) Range Start฀฀eld.
3. Enter the end value in the Port Range End฀฀eld.
4. Select the to be either TCP or UDP or Bot. Protocol
5. Select the Network Type. It may be IPv4 or IPv6 or Both.
6. Select Timeout฀to฀enable฀or฀disable฀฀rewall฀rules฀with฀timeout.
7. Enter Start Time฀to฀start฀the฀respective฀฀rewall฀rule฀effect฀from฀this฀time.
8. Enter Start Date฀to฀start฀the฀respective฀฀rewall฀rule฀effect฀from฀this฀date.
9. Enter End Date฀to฀end฀the฀respective฀฀rewall฀rule฀effect฀on฀this฀date.
10. Enter End Time฀to฀end฀the฀respective฀฀rewall฀rule฀effect฀at฀this฀time.
The time should be in the YYYY/MM/DD:hh-mm format.Note:
11. Select the to determine the rule to Block or Allow.Rule
12. Click to save the changes made.Save
Gigabyte Server Management Console - 96 -
Procedure to add a new User
1. To add a new user, select a free section and click on the empty section. This opens the
Add User screen as shown in the screenshot below.
2. EnterthenameoftheuserintheUserNameeld.
User Name is a string of l to 16 alpha-numeric characters.Note:
It must start with an alphabetical character.
It is case-sensitive.
Special characters ‘-’(hyphen), ‘_’(underscore), ‘@’(at sign) are allowed.
For 20 Bytes password, LAN session will not be established.
3. Set for the new password.Password Size
4. In the and Password Con฀rm Password elds,enterandconrmyournewpassword.
Password should be the combination of alphabets, numbers, symbol and upper Note:
case characters.
Blank space is not allowed.
 Thiseldwillnotallowmorethan16/20charactersbasedonPasswordsizeeldvalue.
 Thiseldwillnotallowthebelowmentionedcharacters.
The password should be a string, if you try to set password using “ipmitool user set
password”.
- 97 - Gigabyte Server Management Console
Hex Char
00 NUL ‘\0’
01 SOH (start of heading)
02 STX (start of text)
03 ETX (end of text)
04 EOT (end of transmission.)
05 ENQ (enquiry)
06 ACK (acknowledge)
07 BEL ‘\a (bell)
08 BS ‘\b’ (backspace)
09 HT ‘\t (horizontal lab)
0A LF ‘\n' (new Line)
0B VT ‘\v’ (vertical tab)
0C FF ‘\f’ (form feed)
0D CR ‘\r’ (carriage ret)
0E SO (shift out)
0F SI (shift in)
10 DLE (data link escape)
11 DC1 (device control 1 )
12 IDC2 (device control 2)
13 DG3 (device control 3)
14 DC4 (device control 4)
15 NAK (negative ack.)
16 SYN (synchronous idle)
17 ETB (end of trans. blk)
18 CAN (cancel)
19 EM (end of medium)
19 EM (end of medium)
1A SUB (substitute)
1B ESC (escape)
1C FS(leseparator)
1D GS (group separator)
1E RS (record separator)
1F US (unit separator)
20 SPACE
7F DEL
Gigabyte Server Management Console - 98 -
5. Enable or Disable the Privilege.Enable User Access
Enabling User Access will intern assign the IPMI messaging privilege to user.Note:
It is recommended that the IPMI messaging option should be enabled for the user to
enable the User Access option, while creating User through IPMI.
6. IntheNetworkPrivilegeandSerialPrevilegeelds,selecttheprivilegesassignedtothe
user which could be Administrator, Operator, User, OEM or None.
7. Check to assign the KVM privilege for the user.KVM Access
8. Check assign the VMedia privilege for the user.VMedia Access
It is recommended that the privileges support to KVM and VMedia should be Note:
provided only to the ADMIN user and shouldn't be provided to USER and OPERATOR
privilege level users. The Admin user can provide the privilege support to USER and
OPERATOR privilege level users at their own risk.
VMedia Privilege only restricts initiating / starting media redirection. If a device is already
being redirected and attached to the host, then in host it will be visible as normal device.
Hence, it will be accessible to all the KVM sessions, which includes ‘KVM Privilege only’
sessions as well.
9. Check the check box to enable SNMP access for the user.SNMP Access
Note: Passwordeldismandatory,ifSNMPStatusisenabled.
10. Choose the SNMP Access level option for user from the SNMP Access level (SHA or
MD5) drop-down list. Either it can be Read Only or Read Write.
11. Choose the SNMP Authentication Protocol (SHA or MD5) to use for SNMP settings
from the drop down list.
Note: Passwordeldismandatory,ifAuthenticationprotocolischanged.
12. Choose the Encryption algorithm to use for SNMP settings from the SNMP Privacy
protocol (AES or DES) drop-down list.
13. In the Email ID eld,entertheemailIDoftheuser.Iftheuserforgetsthepassword,the
newpasswordwillbemailedtotheconguredemailaddress.
Note: SMTPServermustbeconguredtosendemails.
Email Format: Two types of formats are available:
AMI-Format: The subject of this mail format is ‘Alert from (your Host name)’. The
mail content shows sensor information, ex: Sensor type and Description.
Fixed-Subject Format: This format displays the message according to user's
setting. You must set the subject and message for email alert.
14. In the Upload SSH Keyeld,clickBrowseandselecttheSSHkeyle.
Note: SSHkeyleshouldbeofpubtype.
15. Click to save the new user and return to the users list.Save
- 99 - Gigabyte Server Management Console
To Modify User
1. To modify the existing user, click on the active user tab. This opens a User screen as
shown in the screenshot below.
2. Check , if you wish to change the existing Password.Change Password
3. Follow the steps (3 to 15) of Procedure to add a new User.
4. Click to save the changes and return to the users list.Save
5. Click to delete the user.Delete
Gigabyte Server Management Console - 100 -
2-6-16 Video Recording
The Video Recording consists of the following:
1. Auto Video Settings
• Video Trigger Settings
• Video Remote Storage
• Pre-Event Video Recordings
2. SOL Settings
• SOL Trigger Settings
• SOL Video Remote Storage
• SOL Recorded Video
3. SOLJAVA
A sample screenshot of the Video Recording is given below.
A detailed description of the menu items are given below.
Auto Video Settings
The Auto Video Settings page allows you to configure the events that will trigger auto video
recording function of the KVM server and view the current list of user slots for the server. You can
add a new user and modify or delete the existing users.
Thispage is usedto congure the eventsthatwill triggerauto videorecordingfunctionof the
KVM server.
Gigabyte Server Management Console - 102 -
• Watchdog Timer Events
• Chassis Power on Events
• Chassis Power off Events
• Chassis Reset Events
• LPC Reset Events
• Date and Time Event
• Pre-Event Video Recording
• Pre-crash
• Pre-reset
Save: To save the current changes.
Procedure
1. Check the events to be enabled.
2. To set particular Date and Time Event, check the option Date and Time Event.
a) Choosethemonth,dayandyearfromtheDateeld
b) Enter/ChoosetheTimeinhh:mmformatintherespectiveelds.
KVM service should be enabled to perform auto-video recording. The date and Note:
time should be in advance to the system date and time.
3. Click Pre-Event Video RecordingtoeditthePre-Eventvideorecordingcongurations.
A sample screenshot of Pre-Event Video Recordings page is shown as below.
a) To set video quality, select ranges (very low, low, high, average and normal) from
Video Quality drop-down list.
b) To set compression mode, select modes (high, normal, low, no) from Compression
Mode drop-down list.
c) To set number of frames per second, select frames/sec (1-4) from Frames Per
- 105 - Gigabyte Server Management Console
Pre-Event
Pre-Eventvideorecordingleswillbenamedaspereventcaptured.Forexample-ifanyvideois
recordedforCrashEvent,therecordedlewillbenamedaspre_crash_video_x.dat, where x is
lecount,similarlyifitisrecordedforreseteventitwillbenamedaspre_reset_video_x.dat.
Post-Event
Post-Eventvideorecordingleswillbenamedasshownbelow.
video_dump_<Hostname>_%Y%m%dT%H%M%S.dat.
File Count and Duration for Pre and Post Event Recordings are as shown in the below table:
Auto Video Recording (Post
Event)
Pre-Event Video
Recording(only for Crash/reset
event)
Time Limits 20 second s or 5. 5MB video
allowed if Local Storage.
D e f a u lt - 1 0 s e c , b u t ca n b e
congurableupto60sec.
300 seconds recording allowed if
Remote Storage (Remote Path).
Video File Count Local Storage: 2 (After 2, if video
recording starts, the oldest video
file among the two files will be
replaced with the new video)
1 if local storage/3 if remote
storage. (Once Max file count
reached,willDeleteOldvideole
tostorenewle.)
Remo t e Sto r a g e : maxi mum
configured dump value of video
lesforRemoteStorage.
Gigabyte Server Management Console - 106 -
SOL Settings
To open SOL Set page, click from the menu bar. Settings > Video Recording > SOL Settings
A sample screenshot of SOL Settings page is shown below.
TheSOLSettingsconsistsofthreeelds:
• SOL Trigger Settings
• SOL Video Remote Storage
• SOL Recorded Video
SOL Trigger Settings
Event List:Itshowsthelistofavailableeventstobecongured.Theeventsareshownbelow.
• Critical Events (Temperature/Voltage)
• Non Critical Events (Temperature/Voltage)
• Non Recoverable Events (Temperature/Voltage)
• Fan state changed Events
• Watchdog Timer Events
• Chassis Power on Event
• Chassis Power off Event
• Chassis Reset Events
• LPC Reset Events
• Date and Time Events
Save: To save the current changes.
- 107 - Gigabyte Server Management Console
A sample screenshot of SOL Trigger Settings page is shown as below.
Procedure
1. ChecktheeventstobeenabledtocongurewhicheventonthepagewilltriggertheSOL
video recording option to start.
2. To set particular Date and Time Event, check the option .Date and Time Event
a) Choose the month, day and year from the Dateeld
b) Enter the Time inhh:mm:ssformatintherespectiveelds.
The date and time should be in advance to the system date and time.Note:
3. Click to save the changes.Save
SOL Video Remote Storage
Thispageallowsyoutocongurerecordedvideoles.Thesamplescreenshotandvariouselds
of SOL Video Remote Storage are given below.
- 109 - Gigabyte Server Management Console
2-6-17 Fan Policy
The Fan Policy consists of the following:
1. AddNewFanProle
AsamplescreenshotoftheFanProleisgivenbelow.
Procedure to add Fan Prole
Toaddfanprole:
- 111 - Gigabyte Server Management Console
2-6-18 Power Consumption
The Power Consumption is a simple display page for basic power consumption reading
information.Itemonthispagearenon-congurable.
- 103 - Gigabyte Server Management Console
2-7 Remote Control
The system and browser requirements for Remote Control are given below.
System Requirements
• Client machine with 8GB RAM.
• If the client machine has 4GB RAM, there will be lag in Video/keyboard/mouse
functionality.
Supported Browsers
• Chrome latest version.
• IE 11 and above.
• Firefox (with limited support).
It is advisable to use Chrome or IE for H5Viewer, since Firefox has its own Note:
memory limitations.
To open Remote Control page, click Remote Control from the menu bar. A sample screenshot of
the Remote Control page is shown below.
A detailed description of the menu items are given on the next page.
- 105 - Gigabyte Server Management Console
Send Keys: This option is used to key items.
This menu contains the following sub menu items:
• Hold Down
• Press and Release
Hold Down
This menu contains the following sub menu items:
Right Ctrl Key: Thismenuitem can be used to actas theright-side<CTRL> key whenin
Console Redirection.
Right Alt Key:Thismenuitemcanbeusedtoactastheright-side<ALT>keywheninConsole
Redirection.
Right Windows Key:This menuitemcanbeusedtoactastheright-side<WIN>keywhenin
Console Redirection.
Left Ctrl Key:Thismenuitemcanbeusedtoactastheleft-side<CTRL>keywheninConsole
Redirection.
Left Alt Key:Thismenuitemcanbe usedtoact astheleft-side<ALT>keywheninConsole
Redirection.
Left Windows Key:This menu item can be used to actas the left-side <WIN>key whenin
Console Redirection. You can also decide how the key should be pressed: Hold Down or Press
and Release.
Press and Release
Ctrl+Alt+Del:Thismenuitemcanbeusedtoactasifyoudepressedthe<CTRL>,<ALT>and
<DEL>keysdownsimultaneouslyontheserverthatyouareredirecting.
Left Windows Key:This menu item can be used to actas the left-side <WIN>key whenin
Console Redirection. You can also decide how the key should be pressed: Hold Down or Press
and Release.
Right Windows Key:This menuitemcanbeusedtoactastheright-side<WIN>keywhenin
Console Redirection.
Context Menu Key: This menu item can be used to act as the context menu key, when in
Console Redirection.
Print Screen Key: This menu item can be used to act as the print screen key, when in Console
Redirection.
Hot Keys:Thismenuisusedto addtheusercongurableshortcutkeystoinvokein thehost
machine.TheconguredkeyeventsaresavedintheBMC.
This menu contains the following sub menu items:
Add Hot Keys - This menu is used to enable macros. Click Add to macros.
Gigabyte Server Management Console - 110 -
2-8-1 Remote Media
The displayed table showscongured images on BMC.Youcan congureimages of remote
media server.
Note: Morethanoneimagecanbeconguredforeachimagetype.Atmaximum4
 imagescanbecongurable.
 Toconguretheimage,youneedtoenableRemoteMediasupportunder
Settings->Media Redirection - > General Settings.
To start/stop redirection and to delete an image, you must have Administrator Privileges.
Free slots are denoted by “~”
TheeldsofRemoteMediatabareasfollows:
Media Type: Displays type of Media such as CD/DVD, Floppy and Harddisk.
Media Instance: Displays total media instance count.
Image Name: Displays the default recovery image name on the server.
Status: Displays the status of the media.
Session Index: Displays Media Server Session Index.
Start/Stop Redirection: To start or stop Media redirection
Pause: To pause the Media redirection.
Refresh Image List: To get latest Image lists from the Remote Storage.
Procedure
1. To Start/Stop Redirectionandcongure remotemedia images,click(Start/Stopicon)
and make sure Remote Media Support option is enabled.
The Start Redirection button is active only for VMedia enabled users.Note:
2. Selectaconguredslotandclick(Start/Stopicon)tostarttheremotemediaredirection.
It is a toggle button, if the image is successfully redirected, then click (Start/Stop icon) to
stop the remote media redirection.
Redirection needs to be stopped to clear the image.Note:
- 111 - Gigabyte Server Management Console
2-9 Power Control
This page allows you to view and control the power of your server.
To open Power Control, click from the menu bar. A sample screenshot of Power Power Control
Control is shown below.
The various options of Power Control are given below.
Power Off: To immediately power off the server.
Power On: To power on the server.
Power Cycle:Thisoptionwillrstpoweroff,andthenrebootthesystem(coldboot).
Hard Reset: This option will reboot the system without powering off (warm boot).
ACPI Shutdown: This option to initiate operating system shutdown prior to the shutdown.
Perform Action: Click this option to perform the selected operation.
Procedure
Select an action and click Perform Action to proceed with the selected action.
Note: DuringExecutionyouwillbeaskedtoconrmyourchoice.Uponconrmation,you
will be informed about the status after few minutes.
It is advisable to use Chrome or IE for H5Viewer, since Firefox has its own Note:
memory limitations.
- 113 - Gigabyte Server Management Console
2-10-1 Backup Con฀guration
This page฀allows฀you฀to฀select฀the฀speci฀c฀con฀guration฀items฀to฀be฀backed฀up฀in฀case฀of฀“Backu
Con฀guration”.
To฀open฀Backup฀Con฀guration฀page,฀click฀Maintenance > Backup Con฀guration from the menu
bar.฀A฀sample฀screenshot฀of฀Backup฀Con฀guration฀page฀is฀shown฀below.
The฀various฀฀elds฀of฀Backup฀Con฀guration฀page฀are฀given฀below.
Check All฀-฀To฀select฀all฀the฀con฀guration฀list.
Download Con฀g฀ -To฀download฀ and฀ save฀ the฀ con฀guration฀les฀ backup฀ fromBMC฀to฀ client
system.
Procedure
1. Click Check All฀ to฀ backup฀the฀selected฀con฀guration฀ items.฀The฀ Backup฀Con฀guration฀
page will appear as shown above screenshot.
2. Click Download Con฀g฀to฀save฀the฀backup฀฀le฀to฀the฀client฀system.
3. Cick OK฀to฀perform฀the฀backup฀action.฀The฀Backup฀฀le฀will฀be฀saved฀in฀the฀client฀system
4. to cancel the backup process. Click Cancel
TFTP server con฀guration
The฀TFTP฀server฀con฀guration฀is฀used฀for฀exporting฀the฀backup฀฀le.
Note: Ensure that no other TFTP servers are enabled, if so remove all other servers with
฀ all฀con฀guration฀฀les.฀Login฀as฀“super”฀user฀means฀“root”฀user.
Procedure to make the default tftp server
1. Install the application which is needed.
>apt-get install xinetd tftp tftpd
- 115 - Gigabyte Server Management Console
mkdir /tftpboot
chmod -R 777 /tftpboot
chown -R nobody /tftpboot
5. To฀receive฀the฀฀le฀you฀have฀to฀touch฀the฀฀le฀and฀give฀permission฀to฀access฀by฀all฀users
>฀touch฀<DIR>/conf.bak
>฀chmod฀777฀<DIR>/conf.bak
6. Even after all this step has been done and still facing error of timeout:
a)฀ Check฀with฀/etc/xinetd.d/tftp฀฀le฀and฀uncomment฀the฀EOF฀(Remove฀the฀‘#’฀฀ ฀
before the EOF alone).
b) Restart the server.
2-10-2 Firmware Image Location
This฀page฀is฀used฀to฀con฀gure฀฀rmware฀image฀into฀the฀BMC.
To open , click from the Firmware Image Location Maintenance > Firmware Image Location
menu bar.
A sample screenshot of Firmware Image Location page is shown below.
The various options of Image Transfer Protocol are given below.
Image Location Type:฀Type฀of฀location฀to฀transfer฀the฀฀rmware฀image฀into฀the฀BMC฀either฀We
Upload during Flash or TFTP Server.
TFTP Server Address:฀Address฀of฀the฀server฀where฀the฀฀rmware฀image฀is฀stored.
The Server supports both IPv4 and IPv6 addressesNote:
IP Address made of 4 numbers separated by dots as in “xxx.xxx.xxx.xxx”.
Each number ranges from 0 to 255.
First number must not be 0.
IPv6 Address made of 8 groups of 4 Hexadecimal digits separated by colon as in
“xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx.”
- 117 - Gigabyte Server Management Console
The฀various฀฀elds฀of฀Firmware฀Update฀are฀as฀follows:
Preserve all Con฀guration:฀To฀preserve฀all฀con฀guration.
New signimage Public Key: To select the signimage Public Key to be uploaded.
Gigabyte Server Management Console - 118 -
Edit Preserve Con฀guration: To modify the Preserve status settings.
Select Firmware Image: To select the Firmware image to be uploaded.
Start Firmware Update: To start the Firmware Update.
This฀wizard฀ takesyou฀ through฀ theprocessof฀AMIbased฀rmware฀upgradation.฀ The฀ protoc
information฀to฀be฀used฀for฀฀rmware฀image฀transfer฀during฀this฀update฀is฀as฀follows:
Note: All฀con฀guration฀items฀will฀be฀preserved/overwrite฀as฀default฀during฀the฀restore฀฀
฀ con฀guration฀operation.
Procedure
1. Click Preserve all Con฀guration฀to฀preserve฀all฀con฀guration.
2. Click฀Browse฀to฀ select฀฀rmware฀image.฀The฀ Firmware฀update฀undergoes฀ the฀following
steps:
a) Closing all active client requests
b) Preparing Device for Firmware Upgrade
c) Uploading Firmware Image
Note: ฀A฀฀le฀upload฀pop-up฀will฀be฀displayed฀for฀http/https฀but฀in฀the฀case฀of฀tftp฀฀les,฀th
฀ ฀le฀is฀automatically฀uploaded฀displaying฀the฀status฀of฀upload.฀
d)฀ Browse฀and฀select฀the฀Firmware฀image฀to฀฀ash฀and฀click฀Upload.
e) Click Start ฀rmware update start the Firmware Update. A warning message will be
prompted you to proceed further.
f) Click OK to start the Firmware Update. The sample screenshot is shown below
g) Verifying Firmware Image
If฀฀ashing฀is฀required฀for฀all฀images,฀please฀select฀the฀following฀checkbox:
Gigabyte Server Management Console - 122 -
2-10-4 HPM Firmware Update
This฀page฀allows฀you฀to฀update฀the฀HPM฀(Hardware฀Platform฀Management)฀฀rmware.
To configure, choose ‘HPM Firmware Image Location under . To open HPM Maintenance
Firmware Update page, click from the menu bar.Maintenance > HPM Firmware Update
A sample screenshot of HPM Firmware Update page is shown below.
The฀various฀฀elds฀of฀HPM฀Firmware฀Update฀are฀as฀follows:
New signimage Public Key: To select the signimage Public Key to be uploaded.
Select Firmware Image: To select the Firmware image to be uploaded.
Start Firmware Update: To start the Firmware Update.
This฀wizard฀ takes฀you฀ through฀the฀ process฀of฀AMI฀based฀ ฀rmwareupgradation.฀ The฀protoco
information฀to฀be฀used฀for฀฀rmware฀image฀transfer฀during฀this฀update฀is฀as฀follows:
Note: All฀con฀guration฀items฀will฀be฀preserved/overwrite฀as฀default฀during฀the฀restore฀฀
฀ con฀guration฀operation.
Procedure
1. Click Preserve all Con฀guration฀to฀preserve฀all฀con฀guration.
2. Click Browse฀ to฀select฀ ฀rmware฀image.฀ The฀Firmware฀update฀ undergoes฀the฀ following
steps:
- 123 - Gigabyte Server Management Console
a) Closing all active client requests
b) Preparing Device for Firmware Upgrade
c) Uploading Firmware Image
Note: A฀฀le฀upload฀pop-up฀will฀be฀displayed฀for฀http/https฀but฀in฀the฀case฀of฀tftp฀฀les,฀th
฀ ฀le฀is฀automatically฀uploaded฀displaying฀the฀status฀of฀upload.
d)฀ Browse฀and฀select฀the฀Firmware฀image฀to฀฀ash฀and฀click฀Upload.
e) Click Start ฀rmware update start the Firmware Update. A warning message will be
prompted you to proceed further.
f) Click OK to start the Firmware Update. The sample screenshot is shown below.
g) Verifying Firmware Image.
If฀฀ashing฀is฀required฀for฀all฀images,฀please฀select฀the฀following฀checkbox:
If฀only฀few฀module฀versions฀are฀different,฀those฀modules฀will฀be฀฀ashed.
- 125 - Gigabyte Server Management Console
2-10-5 Firmware Information
This฀wizard฀takes฀you฀through฀the฀process฀of฀฀rmware฀upgradation.฀A฀reset฀of฀the฀box฀will฀T
page฀is฀used฀to฀con฀gure฀the฀Firmware฀Information฀settings.
To open System Administrator page, click from the menu Maintenance > Firmware Information
bar. A sample screenshot of Firmware Information page is shown below.
The฀various฀฀elds฀of฀Firmware฀Information฀page฀are฀given฀below.
BMC Firmware Information:
Build Date: Describes the Build Date of the active BMC image.
Build Time: Describes the Build Time of the active BMC image.
Firmware version: Describes the Firmware version of the active BMC image.
BIOS Firmware Information:
Product Manufacturer: Describes the hardware manufacturer.
Product Name: Describes the model name of the device.
Build Date: Describes the Build Date of the device.
Firmware version: Describes the BIOS version of the device.
CPLD Firmware Information:
Firmware version: Describes the CPLD Firmware version.
Gigabyte Server Management Console - 126 -
2-10-6 Preserve Con฀guration
This฀page฀allows฀the฀user฀to฀con฀gure฀the฀preserve฀con฀guration฀items,฀which฀will฀be฀used฀by฀th
Restore฀factory฀defaults฀ to฀preserve฀the฀ existing฀con฀guration฀without฀ overwriting฀with฀defaul
Firmware฀Upgrade฀con฀guration,
To฀ open฀ Preserve฀Con฀guration฀page,฀ click฀ Maintenance > Preserve Con฀guration from the
menu bar.
A฀sample฀screenshot฀of฀Preserve฀Con฀guration฀page฀is฀shown฀below.
The฀various฀฀elds฀of฀Preserve฀Con฀guration฀are฀as฀follows:
Click here to go to Firmware Update or Restore Con฀guration: This link will redirect to the
Firmware฀Update฀or฀Restore฀Con฀guration฀page฀which฀needs฀to฀be฀preserved.
Check All:฀To฀check฀the฀entire฀con฀guration฀list.
Save: To save the current changes.
Note: This฀con฀guration฀is฀used฀by฀Restore฀Factory฀Defaults฀process.
Files Preserved
SDR
Following฀฀les฀will฀be฀preserved:
SDR.dat:฀This฀฀le฀contains฀the฀sensor฀data฀record฀information฀that฀is฀used฀in฀IPMI.
Dependency Con฀gurations - NIL
FRU
Gigabyte Server Management Console - 128 -
registration.
dhcp6c-script:฀This฀ ฀le฀ is฀used฀ to฀con฀gure฀ the฀domain฀ name,฀ DNS฀ server฀IPv6฀ address฀and฀
NTP address.
dhcp6c.conf:฀This฀฀le฀is฀to฀con฀gure฀the฀IPv6฀parameters฀for฀the฀DHCPv6฀clients.
ncsicfg.conf:฀This฀฀le฀is฀to฀con฀gure฀the฀NCSI฀related฀con฀gurations.
nsupdate.conf:฀This฀฀le฀is฀to฀con฀gure฀the฀channel฀ID,฀package฀ID฀for฀the฀NCSI฀interface.
phycfg.conf:This฀le฀ is฀to฀ con฀gure฀ the฀ link฀ speed,฀ duplexand฀ MTU฀ value฀ for฀ the฀ speci฀ed
interface.
dhcp.preip_4:฀This฀฀le฀is฀to฀store฀the฀pre฀IPv4฀address.฀This฀฀le฀will฀be฀created฀at฀runtime.
dns.conf:฀This฀฀le฀ is฀ used฀ to฀ con฀gure฀ the฀DNS฀ registrationmethod฀ and฀ DNS฀ server฀ for฀ the
particular interface.
hostname:฀This฀฀le฀is฀used฀to฀store฀the฀Hostname฀of฀the฀BMC.
hostname.conf:฀This฀฀le฀is฀used฀to฀con฀gure฀the฀host฀name฀creation฀method฀Manual/Automatic฀
for the BMC.
Vlaninterfaces:฀This฀฀le฀helps฀to฀enable฀the฀vlan฀interface฀for฀the฀particular฀LAN฀interface
vlansetting.conf: This file is to store the vlan ID and Vlan priority for the particular VLAN
interface entry.
bond.conf:฀This฀฀le฀is฀to฀enable฀the฀bond฀interface฀for฀the฀speci฀ed฀LAN฀interfaces.
Interfaces:฀This฀ ฀leis฀ to฀ con฀gure฀ the฀ IP/IPV6addressesfor฀ the฀LAN฀ interface฀ using฀ static
DHCP method.
activeslave.conf:฀ This฀ ฀le฀ is฀to฀ con฀gure฀ the฀ active฀ interface฀ for฀ thespeci฀ed฀ bond฀ interface.฀
This฀฀le฀depends฀on฀bond.conf.
hosts:฀This฀฀le฀is฀used฀to฀store฀the฀host฀name฀to฀map฀the฀IP฀address.
hosts.allow:฀This฀฀le฀contains฀the฀list฀of฀hosts฀that฀has฀permission฀to฀access฀the฀system
hosts.deny:฀This฀฀le฀contains฀the฀list฀of฀host฀that฀does฀not฀allow฀accessing฀the฀system
resolv.conf: This file is used to store the nameserver and domain name for hostname
registration.
dhcp6c-script:฀This฀ ฀le฀ is฀used฀ to฀con฀gure฀ the฀domain฀ name,฀ DNS฀ server฀IPv6฀ address฀and฀
NTP address.
dhcp6c.conf:฀This฀฀le฀is฀to฀con฀gure฀the฀IPv6฀parameters฀for฀the฀DHCPv6฀clients.
ncsicfg.conf:฀This฀฀le฀is฀to฀con฀gure฀the฀NCSI฀related฀con฀gurations.
nsupdate.conf:฀This฀฀le฀is฀to฀con฀gure฀the฀channel฀ID,฀package฀ID฀for฀the฀NCSI฀interface.
phycfg.conf:This฀le฀ is฀to฀ con฀gure฀ the฀ link฀ speed,฀ duplexand฀ MTU฀ value฀ for฀ the฀ speci฀ed
interface.
dhcp.preip_4:฀This฀฀le฀is฀to฀store฀the฀pre฀IPv4฀address.฀This฀฀le฀will฀be฀created฀at฀runtime.
NTP
Following฀฀les฀will฀be฀preserved:
ntp.conf: This file contains the NTP dameon protocol configuration parameters such as
synchronization sources, nodes and other related information
ntp.stat:฀This฀฀le฀contains฀the฀auto฀or฀manual฀network฀type฀protocols
adjtime:฀This฀฀le฀contains฀the฀time฀to฀synchronize฀the฀system฀clock
Localtime:This฀ ฀le฀ is฀ the฀system฀ link฀ to฀ the฀ ฀le฀ local฀ time฀ or฀ to฀ the฀ correct฀ time฀ zone฀ in฀ t
system timezone directly.
Dependency Con฀gurations - IPMI
Gigabyte Server Management Console - 132 -
2-10-8 Restore Factory Defaults
In BMC Web GUI, this option is used to restore the factory defaults of the device firmware.
This section lists the configuration items that will be preserved during restore factory default
con฀guration.
Please note that after entering restore factory widgets, other web pages and Warning:
services will not work. All open widgets will be closed automatically. The device will reset
and reboot within few minutes.
To open Restore Factory Defaults page, click from Maintenance > Restore Factory Defaults
the menu bar. A sample screenshot of Restore Factory Defaults page is shown below.
Procedure
1. Click฀Preserve฀Con฀guration฀to฀redirect฀to฀Preserve฀Con฀guration฀page,฀which฀is฀used฀to
preserve฀the฀particular฀con฀guration฀not฀to฀be฀overwritten฀by฀the฀default฀con฀guration.
2. Click฀Restore฀Factory฀Defaults฀to฀restore฀the฀factory฀defaults฀of฀the฀device฀฀rmware
Gigabyte Server Management Console - 134 -
2-10-10 Sign Out
To log out from the Web GUI, click the admin on the top right corner of the screen. A sample
screenshot of admin option is shown below.
Click to perform log out from the Web GUI. A Warning message will be prompted you to Sign Out
proceed further, click to log out else to retain the Web GUI.OK Cancel


Produkt Specifikationer

Mærke: Gigabyte
Kategori: Server
Model: G291-281
Tænd-/slukkontakt: Ja
Vekselstrømsindgangsspænding: 100 - 240 V
Vekselstrømsindgangsfrekvens: 50/60 Hz
Bredde: 448 mm
Dybde: 800 mm
Højde: 87.5 mm
Vægt: 30000 g
Produktfarve: Sort
Pakkevægt: 36000 g
Opbevaringstemperatur (T-T): -40 - 60 °C
Relativ luftfugtighed ved drift (H-H): 8 - 80 %
Relativ luftfugtighed ved opbevaring (H-H): 20 - 95 %
Ethernet LAN-porte (RJ-45): 2
Antal USB 3.2 Gen 1 (3.1 Gen 1) type-A-porte: 2
Ethernet LAN: Ja
Driftstemperatur (T-T): 10 - 35 °C
Ethernet LAN-datahastigheder: 10,100,1000,10000 Mbit/s
Knap til nulstilling: Ja
LED-indikatorer: Ja
Bæredygtighedscertifikater: RoHS
Processorserie: Intel® Xeon®
Maksimal intern hukommelse: 128 GB
On-board grafikkort, model: Aspeed AST2500
Indgangsstrøm: 9.5 - 12 A
Antal VGA-porte (D-sub): 1
Ethernet-grænsefladetype: 10 Gigabit Ethernet,Fast Ethernet,Gigabit Ethernet
Trusted Platform Module (TPM): Ja
Indbygget processer: Ingen
Kobber ethernet kabelteknologi: 10GBASE-T
Antal blæsere: 8 blæser(e)
Understøttet datalagringsdrev typer: HDD & SSD
Antal understøttede lagerdiske: 8
Kabinettype: Stativ (2U)
80 PLUS certificering: 80 PLUS Titanium
Ventilator diameter: 80 mm
Strømforsyning: 2000 W
Processor sokkel: LGA 3647 (Socket P)
Redundant strømforsyning: Ja
Bundkort chipsæt: Intel® C621
Understøttede hukommelsestyper: DDR4-SDRAM
Antal SATA III-stik: 8
LAN Kontroller: Intel® X540-AT2
Hukommelseskanaler: Hexa-channel
Understøttede lagerdrev brugerflader: Serial ATA III
Antal 2.5" bays: 8
RAID-niveauer: 0,1,5,10
Antal understøttede processorer: 2
Hukommelsesspænding: 1.2 V
PCI Ekspres x16 (Gen 3.x) slots: 10
Understøttede lagerdisk størrelser: 2.5 "
Hot-swap HDD båse: Ja
Antal DIMM-slots: 24
Antal af hovedstrømforsyninger: 2
Antal installerede strømforsyninger: 2
IPMI LAN (RJ-45) port: Ja
Antal intern USB 3.2 Gen 1 (3.1 Gen 1) -porte: 1
DC udgående strøm (+12 V): 166.7 A
Rack skinner: Ja
Maksimal RDIMM hukommelse: 64 GB
Intel® Optane™ Memory Ready: Ja

Har du brug for hjælp?

Hvis du har brug for hjælp til Gigabyte G291-281 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Server Gigabyte Manualer

Gigabyte

Gigabyte TO24-JD0 Manual

15 December 2024
Gigabyte

Gigabyte MS33-CP0 Manual

31 August 2024
Gigabyte

Gigabyte R133-X11 Manual

31 August 2024
Gigabyte

Gigabyte R183-S97 Manual

31 August 2024
Gigabyte

Gigabyte R113-C10 Manual

31 August 2024
Gigabyte

Gigabyte R183-SF0 Manual

31 August 2024
Gigabyte

Gigabyte R133-X13 Manual

31 August 2024
Gigabyte

Gigabyte R183-S96 Manual

31 August 2024
Gigabyte

Gigabyte R123-X00 Manual

31 August 2024
Gigabyte

Gigabyte R243-EG0 Manual

31 August 2024

Server Manualer

Nyeste Server Manualer

MSI

MSI S2206-02 Manual

9 Marts 2025
MSI

MSI S1205-01 Manual

9 Marts 2025
MSI

MSI S2206 Manual

9 Marts 2025
IoSafe

IoSafe 224+ Manual

23 Januar 2025
IoSafe

IoSafe 1520+ Manual

23 Januar 2025
IoSafe

IoSafe 218 Manual

23 Januar 2025
IoSafe

IoSafe 1019+ Manual

23 Januar 2025
IoSafe

IoSafe 1515+ Manual

23 Januar 2025