Hager HIB412M Manual

Hager Skifte HIB412M

Læs nedenfor 📖 manual på dansk for Hager HIB412M (3 sider) i kategorien Skifte. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
6LE007719Aa
HIB4xxM
zMotorised changeover switch
125A to 630A
Installation and commissioning
Cabinet /
Back Plate
Installation
Step 1
Connecting the
power section
Step 2
COMMAND /
CONTROL terminal
connections
Step 3
Power SUPPLY
terminal
connections
Step 4
Check
Step 5
Emergency
Manual
Operation
Step 6B
Control by
an external
order (AUTO)
Step 6A
Padlocking
Step 6C
Clip for
storage
of the
emergency
handle
6LE007719Aa1
Preliminary operations
Check the following upon delivery and after removal of
the packaging:
Packaging and contents are in good condition.
• The product reference corresponds to the order.
Contents should include:
- 1 x motorised changeover switch
- 1 x emergency handle and xing clip
- 1 x quick start instruction sheet
Accessories
Bridging bars and connection kits
Terminal shrouds
Terminal shield
This quick start is intended for personnel trained in the
installation and commissioning of this product. For further
details refer to the product instruction manual available
on the hager website.
This product must always be installed and
commissioned by qualied and approved personnel.
Maintenance and servicing operations should be
performed by trained and authorised personnel.
Do not handle any control or power cables connected
to the product when voltage may be, or may become
present on the product, directly through the mains or
indirectly through external circuits.
Always use an appropriate voltage detection device to
conrm the absence of voltage.
Ensure that no metal objects are allowed to fall in the
cabinet (risk of electrical arcing).
Risk of electrocution, burns or injury to
persons and / or damage to equipment.
Risk of damaging the device: In case the
product is dropped or damaged in any way
it is recommended to replace the complete
product.
For 125 - 160A (Uimp = 8 kV). Terminations must
respect a minimum of 8 mm clearance from live parts
to parts intended to be earthed and between poles.
For 200 - 630A (Uimp = 12 kV). Terminations must
respect a minimum of 14 mm clearance from live parts
to parts intended to be earthed and between poles.
Failure to observe good enginering practises as well as
to follow these safety instructions may expose the user
and others to serious injury or death.


Produkt Specifikationer

Mærke: Hager
Kategori: Skifte
Model: HIB412M

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager HIB412M stil et spørgsmål nedenfor, og andre brugere vil svare dig




Skifte Hager Manualer

Hager

Hager ESC225 Manual

1 Januar 2025
Hager

Hager SPB413 Manual

30 December 2025
Hager

Hager HTG465H Manual

30 December 2025
Hager

Hager HIC412G Manual

30 December 2025
Hager

Hager LVSG3CPX Manual

30 December 2025
Hager

Hager EC2560CT Manual

30 December 2025
Hager

Hager VZ218T Manual

30 December 2025
Hager

Hager VU12NC Manual

30 December 2025
Hager

Hager HZC001 Manual

9 December 2024
Hager

Hager VZ118P Manual

9 December 2024

Skifte Manualer

Nyeste Skifte Manualer

Powerfix

Powerfix PSSS 2 A1 Manual

14 Januar 2025
D-Link

D-Link DES-1024D Manual

13 Januar 2025
TRENDnet

TRENDnet TEG-S5g Manual

13 Januar 2025
INOGENI

INOGENI CAM230 Manual

13 Januar 2025
Schneider

Schneider CCT15225 Manual

13 Januar 2025
Luxul

Luxul XMS-5248P Manual

13 Januar 2025
Luxul

Luxul AMS-2624P Manual

13 Januar 2025
Luxul

Luxul XGS-1005 Manual

13 Januar 2025
Luxul

Luxul AGS-1008M Manual

13 Januar 2025