6LE007719Aa
HIB4xxM
zMotorised changeover switch
125A to 630A
Installation and commissioning
Cabinet /
Back Plate
Installation
Step 1
Connecting the
power section
Step 2
COMMAND /
CONTROL terminal
connections
Step 3
Power SUPPLY
terminal
connections
Step 4
Check
Step 5
Emergency
Manual
Operation
Step 6B
Control by
an external
order (AUTO)
Step 6A
Padlocking
Step 6C
Clip for
storage
of the
emergency
handle
6LE007719Aa1
Preliminary operations
Check the following upon delivery and after removal of
the packaging:
Packaging and contents are in good condition.
• The product reference corresponds to the order.
Contents should include:
- 1 x motorised changeover switch
- 1 x emergency handle and xing clip
- 1 x quick start instruction sheet
Accessories
Bridging bars and connection kits
Terminal shrouds
Terminal shield
This quick start is intended for personnel trained in the
installation and commissioning of this product. For further
details refer to the product instruction manual available
on the hager website.
This product must always be installed and
commissioned by qualied and approved personnel.
Maintenance and servicing operations should be
performed by trained and authorised personnel.
Do not handle any control or power cables connected
to the product when voltage may be, or may become
present on the product, directly through the mains or
indirectly through external circuits.
Always use an appropriate voltage detection device to
conrm the absence of voltage.
Ensure that no metal objects are allowed to fall in the
cabinet (risk of electrical arcing).
Risk of electrocution, burns or injury to
persons and / or damage to equipment.
Risk of damaging the device: In case the
product is dropped or damaged in any way
it is recommended to replace the complete
product.
For 125 - 160A (Uimp = 8 kV). Terminations must
respect a minimum of 8 mm clearance from live parts
to parts intended to be earthed and between poles.
For 200 - 630A (Uimp = 12 kV). Terminations must
respect a minimum of 14 mm clearance from live parts
to parts intended to be earthed and between poles.
Failure to observe good enginering practises as well as
to follow these safety instructions may expose the user
and others to serious injury or death.


Produkt Specifikationer

Mærke: Hager
Kategori: Skifte
Model: HIB412M

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager HIB412M stil et spørgsmål nedenfor, og andre brugere vil svare dig




Skifte Hager Manualer

Hager

Hager HZC001 Manual

9 December 2024
Hager

Hager VZ118P Manual

9 December 2024
Hager

Hager VZ418T Manual

9 December 2024
Hager

Hager VZ318P Manual

9 December 2024
Hager

Hager VZ118T Manual

9 December 2024
Hager

Hager VZ218P Manual

9 December 2024
Hager

Hager VZ318T Manual

9 December 2024
Hager

Hager VZ418P Manual

9 December 2024
Hager

Hager KN22E Manual

9 December 2024
Hager

Hager LVSR3TP Manual

9 December 2024

Skifte Manualer

Nyeste Skifte Manualer

Berker

Berker 80161865 Manual

16 December 2024
Berker

Berker 80262280 Manual

16 December 2024
Berker

Berker 80141170 Manual

16 December 2024
Berker

Berker 80162785 Manual

16 December 2024
Berker

Berker 80164773 Manual

16 December 2024
Berker

Berker 80162865 Manual

16 December 2024
Berker

Berker 80162780 Manual

16 December 2024
Berker

Berker 80142170 Manual

16 December 2024
Berker

Berker 80164776 Manual

16 December 2024
Berker

Berker 80262170 Manual

16 December 2024