Electrical Characteristics
Family SB
Number of poles 1P - 2P - 3P - 4P
Frame size Frame size 1 Frame size 2 Frame size 3
Thermal current Ith
(40°C) 16A 25A 32A 40A 63A 80A 100A 125A
Operational frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Rated insulation
voltage (Ui) 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V
Rated impulse with-
stand voltage Uimp 3 KV 3 KV 3 KV 6 KV 6 KV 6 KV 6 KV 6 KV
Protection degree 22233333
Working temperature -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C
Storage temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Operational Currents I
e
Rated voltage Load duty
category
400V AC AC 21A 16A 25A 32A 40A 63A 80A 100A 125A
400V AC AC 22B 16A 25A 32A 40A 63A 80A 100A 125A
400V AC AC 22A 16A 25A 32A 40A 63A 80A 100A 125A
400V AC AC 23A TBA TBA TBA TBA TBA TBA TBA TBA
Short circuit characteristic
Rated short time with-
stand current 1s Icw
(rms)
IEC 60947-3 480A / 1sec 945A / 1 sec 1500A / 1sec
Prospective short
circuit current (rms) EN 60669
3kA 3kA 3kA 6kA 6kA n/a n/a n/a
Associated fuse links
(gG) 16A 25A 32A 40A 63A n/a n/a n/a
Mechanical characteristic
Rigid cable section 16 mm 16 mm 16 mm 25 mm 25 mm 50 mm 50 mm 50 mm22222222
flexible cable section 10 mm 10 mm 10 mm 16 mm 16 mm 35 mm 35 mm 35 mm2 2 2 2 2 2 2 2
Tightening torque 1.8 Nm 1.8 Nm 1.8 Nm 2.8 Nm 2.8 Nm 3.6 Nm 3.6 Nm 3.6 Nm
IP protection degree 20 20 20 20 20 20 20 20
Mechanical endurance
(number of cycle) 100,000 100,000 100,000 30,000 30,000 20,000 20,000 20,000
Electrical endurance @
AC22 (number of cyles) 25,000 25,000 25,000 5,000 5,000 2,500 2,500 2,500
Overall dimension
Width (mm)
1P 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5
2P 17.5 17.5 17.5 35 35 35 35 35
3P 35 35 35 52.5 52.5 52.5 52.5 52.5
4P 35 35 35 70 70 70 70 70
Height (mm) 83 83 83 83 83 83 83 83
Depth (mm) 72 72 72 72 72 72 72 72
Modular Load Break Disconnectors
16A - 125A
Modular
Devices


Produkt Specifikationer

Mærke: Hager
Kategori: Skifte
Model: SBB125

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager SBB125 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Skifte Hager Manualer

Hager

Hager SBB225 Manual

20 September 2024
Hager

Hager JK20210BSD Manual

10 September 2024
Hager

Hager JAB406B Manual

29 August 2024
Hager

Hager JAB403B Manual

28 August 2024
Hager

Hager HA358 Manual

28 August 2024
Hager

Hager JAB402B Manual

28 August 2024
Hager

Hager EGN400AU Manual

27 August 2024
Hager

Hager CDS463G Manual

22 August 2024
Hager

Hager CFB463D Manual

22 August 2024
Hager

Hager CFH440G Manual

22 August 2024

Skifte Manualer

Nyeste Skifte Manualer

Netgear

Netgear GS110TPP Manual

15 Oktober 2024
Lancom

Lancom CS-8132F Manual

7 Oktober 2024
Lancom

Lancom YS-7154CF Manual

7 Oktober 2024
Perel

Perel E305W3-G Manual

5 Oktober 2024
Tork

Tork SS720A Manual

5 Oktober 2024
Black Box

Black Box ACX300-R Manual

4 Oktober 2024