Hager TXM616D Manual

Hager Bryter TXM616D

Læs nedenfor 📖 manual på dansk for Hager TXM616D (4 sider) i kategorien Bryter. Denne guide var nyttig for 35 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
1
6LE002518A
TYM6..
Output 16A C-Load adapted /
shutter/blind
TXM6..
Output 16A C-Load adapted /
shutter/blind
z
Safety instructions
Electrical equipment may only be installed and
-
ance with the relevant installation standards,
guidelines, regulations, directives, safety and
accident prevention regulations of the country.
Failure to comply with these installation
instructions may result in damage to the

-

-
ous voltages to the device or load.

suited for safe disconnection of the mains
supply.



Connect one motor per output only.


switches for correct adjustment. Observe

get damaged.

device could get damaged.
Observe the motor manufacturer's data regard-
ing change-over time and max. switch-on time


of the product and must be retained by the end
user.

auto 1
auto 2
1
2
C1/C9 C3/C11 C5 /C13 C7/C15
C2/C10 C4 /C12 C6/C1 4 C8/C16
(1)
(2) (3)
(3)
(4)
(5)
(6)
Fig. 1: Example device variant 16/8gang
(1) Slide switch / 1/ 2
(2) KNX bus connection terminal
(3) Connections of loads
(4) Labelling eld
(5) Illuminated programming button
(6) Operation button for manual operation for
each pair of outputs with status LED
With variants 20/10gang the basic design corre-
sponds to the 16/8gang device variant.
Function
System information
This device is a product of KNX system and corre-
sponds to the KNX guidelines. Detailed specialised
knowledge obtained from KNX training courses
is required for understanding. The planning,
installation and commissioning of the device is
carried out with the help of KNX-certied software.
P

The function of the device is software-depend-
ent. The software is to be taken from the product
database. You can nd the latest version of the
product database, technical descriptions as well as
conversion and additional support programmes on
our website.

The function of the device is conguration-de-
pendent. The conguration can also be done using
devices developed specially for simple setting and
start-up.
This type of conguration is only possible with
devices of the easylink system. Easylink stands for
easy, visually supported start-up. Precongured
standard functions are assigned to the in/outputs
by means of a service module.
Functional description
The device receives telegrams from sensors or
other controllers via the KNX installation bus and
switches electrical loads with its independent relay
contacts. The devices are particularly suitable for
capacitive loads and are designed for high making
currents.
Correct use
- Switch electrical loads of 230 V AC with poten-
tial-free contacts.
- Switching electrically operated motors of 230 V
AC for blinds, shutters, awnings and similar
hangings.
- Mounting on DIN rail according to DIN EN
60715 in the distribution box.

- manual activation of the outputs on the device
possible, building site operation
- Status display of the outputs on the device
- Scene function
- Forced position by higher-level controller
- Connection of various external conductors
possible.
Functions in switch operation:
- Time switching functions
Functions in roller shutter/blind operation:
- Position can be started directly
- Slat position directly controllable
- Feedback of operating state, shutter position
and slat adjustment
- 3 Alarms
Operation

Bus voltage supply is present.
zPush switch (1) to position 1/ 2.
Manual operation is switched on, the outputs
can be controlled using the operation buttons
(6) independently of each other.
1 activates the control of the outputs
C1 C8 C1 C10 .. (16gang) resp. .. (20gang).
activates the control of the outputs
C9 C16 .. (16gang) resp. C11 ..  (20gang).
During manual operation, the controller is deac-
tivated via the KNX bus.
Systemlink commissioning:
Depending on the programming, the manual
operation is activated permanently or for a time
period congured via the application software.
If the manual operation is blocked via the appli-
cation software, no activation takes place.
Or:
zMove switch (1) to position .
The manual operation is switched off. Operation
takes place solely via the KNX bus. The output
P
P
z
Bn,.:
M
`


Produkt Specifikationer

Mærke: Hager
Kategori: Bryter
Model: TXM616D

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager TXM616D stil et spørgsmål nedenfor, og andre brugere vil svare dig




Bryter Hager Manualer

Hager

Hager TXM646T Manual

27 Maj 2024
Hager

Hager CGA690 Manual

26 Maj 2024
Hager

Hager ESC125 Manual

23 Maj 2024
Hager

Hager CDA625J Manual

13 Maj 2024
Hager

Hager KN14E Manual

8 Maj 2024
Hager

Hager SBN332 Manual

3 Maj 2024
Hager

Hager HW1M406DB Manual

30 April 2024
Hager

Hager LLK721 Manual

28 April 2024
Hager

Hager CDC440J Manual

22 April 2024

Bryter Manualer

Nyeste Bryter Manualer