DS-KAD706Y(-P)
Two-Wire Video & Audio Distributor
1
3
2
1 2 3
4 5
7
1
2 3 4 5
6
8
7 8
6
4
UD29992B
4
12
3
1
2
Network
MAX
MAX
MAX
MAX
MAX
6W
6W
6W
6W
6W
MAX
MAX
MAX
MAX
MAX
6W
6W
6W
6W
6W
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
Network
Door Station
Video/Audio Distributor
Indoor Station
24AWG(0.2 m, 9
Ω/100 m)
20AWG(0.5 m, 3.5
Ω/100 m)
18AWG(0.8 m, 2.5
Ω/100 m)
All
DS-KAD706Y - DS-KAD706Y-S Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
DS-KAD706Y - DS-KAD706Y Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
DS-KAD706Y-DS- KD8003Y-IME2 Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
DS-KAD706Y-DS-KH6320Y-WTE2 Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Twisted Pair Parallel lines
Routing Path
MAX
MAX
MAX
MAX
MAX
6W
6W
6W
6W
6W
24VDC
24VDC
24VDC
24VDC
24VDC
MAX
MAX
MAX
MAX
MAX
6W
6W
6W
6W
6W
24VDC
24VDC
24VDC
24VDC
24VDC
24 VDC
Power Input
Diagram References
Appearance
Power Indicator
Cascade Interface
Network Indicator
Network Interface Cascade Network Indicator
Reset ButtonPower Input
Terminals
Wiring
Wire the devices with power supply cables as picture shown.
Door station should be connected to CH6 of the video/audio distributor with two-wire cables.
Indoor Station should be connected to any terminal of CH1 to CH5 of the video/audio distributor
with two-wire cables.
Caution: Make sure all the related equipment is power-off during the installation.
The power output of CH1 to CH5: 24 VDC, Max. 6W.
The power output of CH6: 24VDC, Max. 16 W.
Installation
Before you begin:
Make sure the device in the package is in good condition.
● Make sure all the related equipment is power-off during the installation.
● Check the product specification for the installation environment.
Wall Mounting
1. Fix the DIN rail onto the wall.
Note: You are required to utilize a matched DIN rail.
2. Press the red clip upward, and lock it to the DIN rail.
Tips for Cables and Installation
Cables and Wiring
When there are multiple cores in one parallel line, only one pair of closed cores are allowed
to transmit signal. It is not allowed to use multiple pair of cores in one cable to transmit
signal.
When using parallel lines, it is suggested to use those with shielding layer. If dual core or
multiple core parallel lines without shielding layer are routed, stability of signal
transmission can be effected. You need to run a test before installation.
Impedance of cable should not be over suggested value, or distributor cannot transmit
enough power to indoor station or door station.
Strong electricity and weak electricity cannot be wired in the same route, they need to be
wired separately and the distance should be more than 0.5 meter.
All the cables used need to follow the restriction in the following table.
Device Installation
Installation environment (temperature, moisture etc.) needs to follow requirements in
specification or power output can be effected.
Power consumption of modular door station (main module and sub modules) should be less
than 12W. Please reach local technical support if you are not sure about power consumption
of each module. Door station should be connected to CH6 of the video/audio distributor. If
modular door station is connected to any terminal of CH1 to CH5, up to 3 sub modules can
be connected.
Indoor station should be connected to any terminal of CH1 to CH5 of the video/audio
distributor.
Up to 15 video/audio distributor can be cascaded. If more distributors are needed, you
should cascade network switch supporting 1000Mbps. The whole 2-wire system can have up
to 500 devices.
Power supply must be certified by Hikvision.
Indoor station needs to use firmware released after October, 2019.
Note: The power source should be qualified and meet limited power
source or PS2 requirements according to IEC 60950-1 or IEC 62368-1 standard.
Note:
The indoor station and doorstation are not contained in the package.
The adapter is contained in the DS-KAD706Y-P package.
Model Manufacturer
KPL-060M-II Channel Well Technology Co., Ltd
The detail for the power adapter contained
in the package is as follows:


Produkt Specifikationer

Mærke: Hikvision
Kategori: Ikke kategoriseret
Model: DS-KAD706Y

Har du brug for hjælp?

Hvis du har brug for hjælp til Hikvision DS-KAD706Y stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Hikvision Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024