Side 1/4
DS-KV1101-ME2
Analog Villa Door Staon UD20935B-B
Camera 2Call Buon
3Microphone
4TAMPER
5
Terminals
6Debugging Port
7DIP Switch
8
Note: The debugging port is used for debugging only.
Terminal and Wiring
2
Installaon Accessory
3
ENGLISH
Diagram References
Appearance
1
Flush Mounng with Gang Box (Type I)
1. Cave the installaon hole in the wall.
Note: The suggested dimension of the installaon hole should be larger than the gang box.
2. Insert the gang box to the hole chiseled on the wall.
3. Fix the mounng plate to the gang box with 2 screws.
Note: The dimension of the gang box is 75mm(width) 75 mm length 46 mm depth the le and × ( ) × ( ),
right holes will be applies.
4. Secure the door staon to the mounng plate with the set screw.
Surface Mounng without Gang Box
Make sure all related equipments are power-off during the installaon.
Tools that you need to prepare for installaon:
Drill (ø2.846) and gradienter.
Purchase the protecve shield before installaon.
Before You Start
1. Sck the mounng template on the wall. Drill the screw holes according to the
mounng template. Remove the mounng template from the wall.
2. Align and secure the mounng plate on the wall with 4 supplied screws according to
the screw holes.
3. Install the door staon to the mounng plate. Fix the device on the mounng plate
with the set screw.
1
Local Operaon
5
1
3
2
3
4
5
6
7
8
9
1Loudspeaker
NC: Door Lock Relay Output (NC)
NO: Door Lock Relay Output (NO)
COM: Common Interface
12 VDC OUT: Power Supply Output
GND: Grounding
Juncon Box 21 Mounng Plate
Note:
The dimension of the juncon box is 159.9 mm × 86.7 mm × 53.59 mm.
The dimension of the mounng plate is 142 mm × 82.87 mm × 43.38 mm.
Installaon
4
Note: Video intercom villa door staon supports surface mounng.
2
Wire the door staon to the indoor staon with 2-wire cables.
You can call the resident by pressing the call buon.
Press the call buon of the door staon, all linked indoor staons start ringing.
Note: While one of linked indoor staons receive the call, the others will stop ringing.
Flush Mounng with Juncon Box
1. Cave the installaon hole, and pull the cable out.
Note: The suggest dimension of the installaon hole is
2. Sck the mounng template into to the installaon hole.
3. Insert the juncon box into the hole and fix it with 4 screws according to the screws
holes.
4. Insert the door staon into the juncon box, and fix it with set screw.
Flush Mounng with Gang Box (Type II)
1. Cave the installaon hole in the wall.
Note: The suggested dimension of the installaon hole should be larger than the gang box.
2. Insert the gang box to the hole chiseled on the wall.
3. Fix the mounng plate to the gang box with 2 screws.
Note: The dimension of the gang box is 55mm(width) 101 mm length 38 5 mm depth the upper × ( ) × . ( ),
and lower holes will be applies.
4. Secure the door staon to the mounng plate with the set screw.
There are 2 size of the gang boxes adapted to the device.
Size 1: 75 mm(width) 75 mm(length) 46 mm(depth).× ×
Size 2: 55 mm(width) 101 mm(length) 38.5 mm(depth).× ×
DIP Switch
DIP 1 is used to coding the address of door staon. DIP 2, 3,4 are used to coding the unlock
duraon.
LP/LN: For the access of Indoor Staon
Unlock
Duraon(s) 1 2 3 4 5 6 7 8
DIP 2
DIP 3
DIP 4
OFF OFF OFF OFF
OFF OFF
OFF OFF
OFF
OFF
OFF
OFF
ON
ON ON ON
ON ON
ON ON ON
ON
ON
ON
AddressDIP 1
OFF
ON
1
2
1
2
Flush Mounng with Gang Box (Type I) Flush Mounng with Gang Box (Type II)
Surface Mounng without Gang Box Flush Mounng with Juncon Box
4
1
2
3
1
2
3
4
1
2
3
4
1
2
3
4
Set Screw Door Staon Screws Mounng Plate Mounng Template Wall Set Screw Door Staon Screws Mounng Plate Mounng Template Wall
Set Screw Door Staon Screws Mounng Plate Gang Box Wall Set Screw Door Staon Screws Mounng Plate Gang Box Wall
Unit:mm
Unit:mm
43.38
82.87
72.2
142
53.59
86.7
159.91
120
8.78
15
30
AIN1/AIN2/AIN3/AIN4: For the access of Alarm Input Device
Up to 2 door staon can be connected to the system.
Switch the DIP 1 to set the address of the door staon. The address is unique.
1Unlock Duraon
Switch the DIP 2, 3, 4 to coding the unlock duraon of the door staon. Refers to
the Terminal and Wiring for details.
Note: Unlock duraon ranges from 1 to 8 seconds.
2Call Resident
NO2
COM2
NC2
NO1
COM1
NC1
GND
12VOUT
LP
LN
AIN4
AIN3
AIN2
AIN1
GND
GND
ALARM IN
Screw for Volume Adjustment
9
Scan the following QR Code to get the
device communicaon matrix.
Note that the matrix contains all communicaon
ports of Hikvision access control and video
intercom devices.
Scan the following QR Code to get the
device common serial port commands.
Note that the command list contains all
commonly used serial ports commands for all
Hikvision access control and video intercom
devices.


Produkt Specifikationer

Mærke: Hikvision
Kategori: Ikke kategoriseret
Model: DS-KV1101-ME2/Flush

Har du brug for hjælp?

Hvis du har brug for hjælp til Hikvision DS-KV1101-ME2/Flush stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Hikvision Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024