Side 1/46
Portable Evaporative Air Cooler
User Manual
Read and save these instructions before use
EN
Rafraîchisseur d'air par évaporation portatif
Mode d'emploi
Lire ces instructions avant l'utilisation et
les conserver
FR
Enfriador de Aire Evaporativo Portátil
Manual de Usuario
Lea y guarde estas instrucciones antes
de usar la unidad
ES
Customer Support:
Assistance Au Client:
Servicio de atencion a clientes:
Web: www.jmatek.com
USA: 1-800-474-2147 | usinfo@jmatek.com
CANADA^: canadainfo@jmatek.com
^ Canada Customer Support service available for models sold in Canada only.
^ Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien.
^ Servicio de Atención A Clientes en Canadá disponible solo para modelos vendidos en Canadá.
Model / Modèle / Modelo:
CS10PE Series / Série / Serie
1
THANK YOU
SAFETY RULES
Congratulations on your purchase of this Honeywell Evaporative Air Cooler.
The Safety & Maintenance Guide and the separate User Manual are intended to provide you with
important information needed to set up, operate, maintain and troubleshoot this product.
EN
The Air Cooler Guide and User Manual are intended to provide important information needed to
set up, operate, maintain and troubleshoot your Air Cooler. Failure to follow these instructions may
damage and/or impair its operation, create hazards, and void the warranty. In case there is any
inconsistency or conflict between the English version and any other language version of the content
of this material, the English version shall prevail.
WARNING—READ AND SAVE THE AIR COOLER GUIDE AND USER MANUAL
READ AND SAVE THESE INSTRUCTIONS:
When using electrical appliances, basic safety precautions should always be followed:
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
DO NOT operate with a damaged cord or plug. If the supply cord is damaged, it must be replaced
with a supply cord which is as per manufacturers specifications, by the authorized service centre
or its service agent or a similarly qualified person in order to avoid a hazard.
Before operating the product, remove the packaging and check that product is in good condition.
DO NOT allow children to play with this appliance, packaging or plastic bags.
Check the household voltage to ensure it matches the appliance’s rating specifications.
DO NOT use an extension cord with this unit.
DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from
areas where it may be tripped over.
Always ensure the water tank is filled with water above the "min." level mark, when operating the
air cooler in evaporative COOLING mode.
Always unplug the Air Cooler before refilling the water tank, cleaning, servicing or relocating the
unit.
2
SAFETY RULES (CONTINUED)
EN
Never pull the cord. Remove it from the electrical outlet/ socket by grasping and pulling on the
plug-end of the cord.
This appliance has been manufactured for use in domestic environments and must not be used
for other purposes.
DO NOT use in areas where gasoline, paint or other flammable goods and objects are stored.
DO NOT operate the unit on COOL setting with an empty tank as this may result in damage to the
water pump.
DO NOT attempt to repair or adjust any electrical or mechanical functions of the Air Cooler, as
this may void the warranty.
DO NOT cover the cooler’s air inlet or outlet, as this may damage the motor.
DO NOT insert or allow objects to enter any ventilation or exhaust opening, as this may damage
the unit and may cause electrical shock or fire.
DO NOT operate with the Honeycomb Cooling Media removed, as this will overload and damage
the motor.
DO NOT leave the operating appliance unattended for an extended period of time.
DO NOT operate this unit if it is damaged or malfunctions. Refer to the Troubleshooting section.
If problem still exists contact the Customer Support Center.
Always place the unit on a dry level floor.
DO NOT use in bathrooms or near water. DO NOT keep the product where it may fall into water or
a water container.
Store in a dry area when not in use.
Always grip the side handles to move the Air Cooler.
WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid
state speed control device.
3
USER TIPS
EN
Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep energy costs
low. Warm air is drawn into the cooler and enters the Honeycomb Cooling Media. Water pumped
from the water tank pours over the Honeycomb Cooling Media. As the warm air passes through the
Honeycomb Cooling Media, the water absorbs the heat, naturally cooling and humidifying the air. A
fan propels the cooled air out into the room. This no-compressor system cools naturally, efficiently
and inexpensively.
The recommended maximum relative humidity level is 60% or less, which allows a noticeable
temperature decrease. The temperature will be lower in drier climates because higher evaporation
occurs when the humidity is low.
What is Evaporative Cooling?
Evaporative Air Cooling Mechanism
Honeycomb Cooling Media
Warm Air Cool Air
Pump Water
NOTE
When the product is used for the rst time the Honeycomb Cooling Media will have an odor which
will dissipate in a few hours or so of initial use.
4
COOLER LOCATION
EN
Indoors
Place the cooler in front of an open door or window. Ensure that there is adequate cross-ventilation
in the room by leaving a door or window open opposite the cooler.
The Evaporative Air Cooler should not be used in enclosed spaces. It must be kept level and there
must be water in the water tank. Doors and windows should be opened to allow free air flow. The
Evaporative Air Cooler works best when placed near an open window, so that outside air is drawn into
the Evaporative Air Cooler, circulates in the room, then exits via the door. The maximum cooling effect
is felt when a person is near the ow of air coming out of the Evaporative Air Cooler. The Evaporative
Air Cooler produces moisture and can be used to humidify dry air. To be used for humidification the
windows and doors should be closed.
To maximize efficiency, position the Air Cooler according to the following guidelines:
IMPORTANT: The evaporative air cooler is not an air conditioner as it does not use a compressor or
refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner.
IMPORTANT: Honeywell Outdoor Air Cooler models are designed to IPX4 product standards and not
recommended to be placed outdoors during heavy rain or snow.
Outdoors (for outdoor models only)
Use only on GFCI Protected outlets/ sockets (for USA only). Press the TEST button (then RESET
button) every month to ensure proper operation.
Power cords must be secured to avoid tripping.
The wiring and connections must be protected from water. The electrical plug and Air Cooler
connections must be dry at all times. When used outdoors, insert the air cooler electrical plug
into an IP44 compliant outdoor electrical outlet.
Set the unit on a solid flat surface.
5
STORAGE AND MAINTENANCE GUIDELINES
EN
Read the detailed CLEANING & DRAINING THE WATER TANK instructions for your Air Cooler, located
in the separate User Manual. Below is a general guideline for maintenance and storage of your Air
Cooler.
WARNING: Always switch OFF the Air Cooler and unplug it from the electrical source before
cleaning or maintenance.
Cleaning
At least once a week, drain the water tank completely and refill with fresh water. Doing this will greatly
reduce mineral deposits and help to extend the life of the Honeycomb Cooling Media.
End of Season Storage
If the Air Cooler will not be used for a long time:
Make sure all parts are dry by running the Fan Only mode for about 1 to 2 hours before storing
(time depends on ambient humidity conditions).
Switch OFF the Air Cooler and unplug from the power supply.
Empty/drain all the water from the tank. Note: If the unit is connected to a continuous water
supply, you must switch off the water supply and remove the drain tube before draining the
water tank. This function is only available on some Honeywell Air Cooler models. Check the User
Manual to see if your unit has the Continuous Water Supply Function.
Clean the water tank with a damp cloth to wipe away any dust or mineral deposits.
Remove the Honeycomb Cooling Media and Carbon Dust Filter* from the Air Cooler and rinse
under fresh water to remove dust and dirt.
Replace the Honeycomb Cooling Media and Carbon Dust Filter* after they are clean and dry.
To protect the unit from dust, moisture and scratches, cover with a clean cloth, tarp or plastic bag
before storing.
Coil the power cord and store it away from the floor to protect it.
Store this unit at room temperature in a dry location, away from direct sunlight and/or very hot,
cold or damp environments.
Carbon Dust Filter is available in specific models of Honeywell Air Coolers only.
Check the Parts Description in the User Manual for your model to see if it includes a Carbon
Dust Filter.
*
6
TROUBLESHOOTING GUIDE
EN
Customer Service Center Contact: See last page of User Manual.
PROBLEM POSSIBLE CAUSE SOLUTION
No discharge of
air.
Cord is not plugged in. Make sure power cord is plugged in and the switch is
ON.
Power is not ON.
Turn the unit ON by pressing the power button on the
control panel / remote control or turn the SPEED
knob.
Not Cooling /
Unit is making
noise.
Pump is not turned ON. Turn on COOL function from remote or control panel.
Low or no water in tank,
when COOL is selected. Refill water tank.
Damaged Pump or
Calcium deposits on
blower.
Contact Customer Service Center.
Excessive
humidity in the
room.
In cooling mode, the Air
Cooler produces moisture
as a result of evaporative
cooling. This is normal.
The Air Cooler cools best in dry climates. If the
ambient humidity level is high (approx. 60% or
above), refrain from using the Air Cooler until ambient
humidity is reduced.
Make sure the window/doors are open and there
is adequate cross-ventilation in the room so that
the moisturized air can circulate better. Do not use
the evaporative cooling function on days with high
ambient humidity.
Odors.
When the Cooler is new.
When the unit is used for the first time, the
Honeycomb Cooling Media will have an odor, which
will dissipate within a few hours of initial use.
Algae or mold due to
moist parts. In very damp
conditions, algae may
form.
Check the Honeycomb Cooling Media. If you see
mold spots on the media or suspect an algae issue,
remove and replace the Honeycomb Cooling Media.
Contact the Customer Service Center for more
information.


Produkt Specifikationer

Mærke: Honeywell
Kategori: Klimaanlæg
Model: CS10PE

Har du brug for hjælp?

Hvis du har brug for hjælp til Honeywell CS10PE stil et spørgsmål nedenfor, og andre brugere vil svare dig




Klimaanlæg Honeywell Manualer

Klimaanlæg Manualer

Nyeste Klimaanlæg Manualer