Honeywell TC10PM Series Air Cooler Manual

Honeywell Ventilator TC10PM Series Air Cooler

Læs nedenfor 📖 manual på dansk for Honeywell TC10PM Series Air Cooler (67 sider) i kategorien Ventilator. Denne guide var nyttig for 20 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/67
Portable Evaporative Air Cooler
User Manual
Read and save these instructions before use
EN
Przenosny Parowy Klimator
Instrukcja obsługi
Przeczytaj i zachowaj tę instrukcję przed użyciem
PL
Draagbare Verdamping Luchtkoelers
Gebruiksaanwijzing
Lees de gebruiksaanwijzing zorgvuldig en
bewaar deze goed
NL
Raffrescatori Evaporativi Portatili
Manuale Utente
Leggere attentamente le istruzioni prima
dell'utilizzo dell'apparecchio
IT
Portátil por Evaporação Ventilador do Ar
Manual do Utilizador
Leia e guarde estas instruções antes da
utilização
PT
Portabel Evaporativ Luftkylare
Luftkylare Användarmanual
Läs och spara dessa instruktioner innan användning
SE
Transportabel Fordampende Luftkøler
Brugervejledning
Læs og gemme disse instrukser inden brug
DK
Rafraîchisseur d'air par évaporation portatif
Mode d'emploi
Lire ces instructions avant l'utilisation et
les conserver
FR
Taınabilir Buharlı Sogutucu Kullanma
Kılavuzu
Kullanmadan önce bu talimatları okuyun ve
saklayın
TR
Tragbare Verdunstungs Luftkühler
Benutzerhandbuch
Lesen sie die anleitung vor dem gebrauch
und heben sie sie auf
DE
Enfriador de Aire Evaporativo Portátil
Manual de Instrucciones
Lea y guarde estas instrucciones antes
de usar la unidad
ES
Мобильная Климатическая Установка
Руководство пользователя
Прочтите и сохраните эту инструкцию перед
использованием
RU
Siirrettävät Höyrystävät Ilmanjäähdyttimet
Käyttäjän Opas
Lue ohjeet ennen käyttöä ja säästä ne
FI
Model / Modèle / Modelo / Modello /
Mallien / Modeller / Modell / Мoдэль :
TC10PM Series
www.honeywellaircoolers.com
info@honeywellaircoolers.com
2
USE & OPERATION
EN
CONTROL PANEL
OOFF
Icons on Control Panel
Swing
Power OffO
Cool
= Low
= Medium
= High
3
USE & OPERATION (CONTINUED)
EN
FUNCTION BUTTONS
SPEED
Connect to the power supply and turn the SPEED knob. The fan will start. Change the speed from
Low to High (| for Low, || for Medium and ||| for High fan speed). To switch off the unit, turn the
SPEED knob to O.
COOL / SWING
You must add water before operating the unit on Cool mode. Turn the COOL
position to activate evaporative cooling. The water pump will operate and you
will feel the cooler air after the Honeycomb Cooling Media is completely wet.
Turn the COOL / SWING position to activate evaporative cooling and
the movement of the louvers. The louvers will begin to move left to right
automatically. Vertical Air Flow - You can manually adjust the lever
located at the front of the unit to change vertical air flow.
Turn the SWING position to activate the movement of the louvers.
Make sure to position the air cooler correctly before you set up and start using the product. Please
refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide.
COOLER LOCATION
Louver
Movement
4
USE & OPERATION (CONTINUED)
EN
CAUTION: Unplug the unit from the electrical socket before emptying or refilling the water tank.
Open the Water Fill Door located on the back of the unit.
The Water Level Indicator is located at the front of the unit. Refill
the water tank when water level is low. Do not fill water above the
"Max." water level mark to avoid water droplets collecting on
the louvers. Check the water level in the tank before running the
COOL function. Make sure that the water in the tank is above
the minimum water level mark. Running the unit in COOL mode
with inadequate water may cause pump failure.
Note: The water capacity refers to the total volume of water that can be contained within the air
cooler water tank and water distribution system. The water capacity in the tank at the “Max.” indicator
level may be lower than the actual water capacity of the air cooler.
WARNING: Do not fill water tank with dirty water or salt water. This can damage the unit and
Honeycomb media.
FILLING WITH WATER
Below are instructions on how to clean and maintain your air cooler. If the cooler will not be used
for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in
the separate Safety & Maintenance Guide.
WARNING:
Before cleaning the unit, power OFF the unit and disconnect from the electrical socket.
CLEANING & DRAINING THE WATER TANK
• Move the unit to a location where the water can be drained. Remove the cap from the drain plug
located at the bottom of the unit. Allow the tank to empty.
• Refill the water tank with clean water, up to the maximum level and drain it completely.
• Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive
elements or chemicals to clean this product.
• When the product is not in use, store the unit in a dry place out of direct sunlight.
Water Fill Door
5
USE & OPERATION (CONTINUED)
EN
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect the power adapter from the unit and
electrical socket.
CLEANING THE MESH FILTER AND HONEYCOMB COOLING MEDIA
The appliance is supplied with a Mesh Filter and Honeycomb Cooling Media.
The Mesh Filter and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1
for instructions on how to remove them from the unit for cleaning and maintenance.
Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank
and refill with fresh water, especially if the tank has not been cleaned in a long time.
The cleaning frequency for the Honeycomb media depends on local air and water conditions.
In areas where the mineral content of water is high, mineral deposits may build up on the
Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh
water at least once a week will help reduce mineral deposits. If mineral deposits remain on the
Honeycomb Cooling Media, the media should be removed and washed under fresh water. The
media should be cleaned every two months or sooner, depending on your needs.
For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool
function 15 minutes before turning the unit off.
Figure 1:
Carefully pull out the rear grill / mesh filter from the
cooler.
Rinse the rear grill / mesh filter with clean water and let
it dry before re-installing to the unit.
Carefully pull out the Honeycomb Media from the
Honeycomb Frame.
Replace or clean media with water and a damp cloth as
needed.
WARNING: DO NOT operate the Air Cooler when the
Rear Grill is removed from the Air Cooler, or if there is a
loose-fitting Rear Grill. Doing so can cause serious
injury or dangerous electrical shock.
1.
2.
3.
4.
Honeycomb Cooling Media
Honeycomb
Frame
Rear Grill/
Mesh Filter
Removing the Mesh Filter and Honeycomb Cooling Media:
1
DESCRIPTION DES PIECES
FR
1) Panneau de contrôle 6) Grille arrière & filter
2) Grilles d'aération 7) Système de refroidissement
en nid d’abeilles
3) Indicateur de niveau d'eau 8) Porte de remplissage d'eau
4) Roulettes 9) Cordon electrique
& prise
5) Poignée 10) Bouchon de vidange
AVERTISSEMENT -- LIRE ET SAUVEGARDER LE GUIDE DE SECURITE ET D'ENTRETIEN ET LE
MANUEL D'UTILISATION DU REFROIDISSEUR D'AIR AVANT D'UTILISER LE PRODUIT. NE PAS
SUIVRE CES INSTRUCTIONS POURRAIT ENDOMMAGER ET/OU PORTER ATTEINTE A SON
FONCTIONNEMENT ET ANNULER LA GARANTIE. EN CAS D'INCOHERENCE OU DE CONFLIT
ENTRE LA VERSION ANGLAISE ET TOUT AUTRE VERSION LINGUISTIQUE DU CONTENU DE CE
MATERIEL, LA VERSION ANGLAISE PRÉVAUDRA.
15
26
7
8
3
4
9
10
2
UTILISATION ET FONCTIONNEMENT
FR
PANNEAU DE COMMANDE
Icônes sur l’écran d’affichage
Vitesse
Oscillation
ÉteindreO
Refroidissement
= Faible
= Moyenne
= Élevée
OOFF


Produkt Specifikationer

Mærke: Honeywell
Kategori: Ventilator
Model: TC10PM Series Air Cooler

Har du brug for hjælp?

Hvis du har brug for hjælp til Honeywell TC10PM Series Air Cooler stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ventilator Honeywell Manualer

Ventilator Manualer

Nyeste Ventilator Manualer

ECG

ECG FT 23a Manual

1 Marts 2025
ECG

ECG FT 30a Manual

1 Marts 2025
Columbia Vac

Columbia Vac WKC20 Manual

28 Februar 2025
Ideal

Ideal ID2501 Manual

27 Februar 2025
Dimplex

Dimplex DCPFQ40 Manual

26 Februar 2025
Dimplex

Dimplex DCDF30A Manual

26 Februar 2025
Dimplex

Dimplex DCTFP92 Manual

26 Februar 2025
Dimplex

Dimplex DCAC20F Manual

26 Februar 2025
Midea

Midea FZ10-17JRA Manual

26 Februar 2025