HP ProCurve 2600 Manual

HP Ikke kategoriseret ProCurve 2600

Læs nedenfor 📖 manual på dansk for HP ProCurve 2600 (116 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 122 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/116
Installation and
Getting Started Guide
www.procurve.com
ProCurve Series
2600 Switches
PoE
Power over Ethernet Devices
ProCurve Series 2600 Switches
Installation and Getting Started Guide
Hewlett-Packard Company
8000 Foothills Boulevard, m/s 5552
Roseville, California 95747-5552
http://www.procurve.com
© Copyright 2001, 2008 Hewlett-Packard Development 2005,
Company, L.P. The information contained herein is subject to
change without notice.
This document contains proprietary information, which is
protected by copyright. No part of this document may be
photocopied, reproduced, or translation into another language
without the prior written consent of Hewlett-Packard.
Publication Number
5991-2165, January 2008
Applicable Products
Trademark Credits
Windows® is a US registered trademark of Microsoft
Corporation.
Disclaimer
HEWLETT-PACKARD COMPANY MAKES NO WARRANTY
OF ANY KIND WITH REGARD TO THIS MATERIAL,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be
liable for errors contained herein or for incidental or consequential
damages in connection with the furnishing, performance, or use
of this material.
The only warranties for HP products and services are set forth in
the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an
additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
Hewlett-Packard assumes no responsibility for the use or
reliability of its software on equipment that is not furnished by
Hewlett-Packard.
Warranty
See the Customer Support/Warranty booklet included with the
product.
A copy of the specific warranty terms applicable to your Hewlett-
Packard products and replacement parts can be obtained from your
HP Sales and Service Office or authorized dealer.
ProCurve Switch 2626-PWR (J8164A)
ProCurve Switch 2650-PWR (J8165A)
ProCurve Switch 2600-8-PWR with Gigabit Uplink (J8762A)
ProCurve 600 Redundant and External
Power Supply
(J8168A)
ProCurve 610 External Power Supply (J8169A)
ProCurve Switch 2626 (J4900B)
ProCurve Switch 2650 (J4899B)
iii
Contents
1 Introducing the Switch
Front of the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Multiple-Display Port LEDs - Port LED View or
LED Mode Select Button and Indicator LEDs . . . . . . . . . . . . . . . . 1-7
Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Clear Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Back of the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Switch Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
2 Installing the Switch
Included Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Installation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
1. Prepare the Installation Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2. Installing or Removing mini-GBICs . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
3. Verify the Switch Passes Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
LED Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
4. Mount the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Rack or Cabinet Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Rack Mounting the 2626-PWR and 2650-PWR switches . . . . . . . 2-12
Rack Mounting the Non-PWR Switches
and the 2600-8-PWR Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Flat Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Wall mounting the Series 2600 Non-PWR Switches . . . . . . . . . . 2-17
Wall mounting the Series 2600-8-PWR Switch . . . . . . . . . . . . . . . 2-18
Horizontal Surface Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
5. Connect the Switch to a Power Source . . . . . . . . . . . . . . . . . . . . . . 2-19
iv
6. Connect the Network Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Using the RJ-45 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Connecting Cables to mini-GBICs . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
7. (Optional) Connect a Redundant Power Supply
to a Series 2600-PWR Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
RPS/EPS Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
Operating Characteristics of the 600 RPS/EPS (J8168A) . . . . . . 2-22
600 RPS/EPS LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23
610 EPS LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27
Operating Characteristics of the 610 EPS (J8169A) . . . . . . . . . . 2-27
8. (Optional) Connect a Console to the Switch . . . . . . . . . . . . . . . . . . 2-30
Terminal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30
Direct Console Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Sample Network Topologies for
Non-PWR Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
As a Desktop Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
As a Segment Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Connecting to a Backbone Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Sample Network Topologies for PWR Switches . . . . . . . . . . . . . . . . . . . . 2-36
As a Desktop Switch Implementing PoE . . . . . . . . . . . . . . . . . . . . . . . 2-36
As a Segment Switch Implementing PoE . . . . . . . . . . . . . . . . . . . . . . . 2-37
Stacking the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
3 Configuring the Switch
Recommended Minimal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Using the Console Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Where to Go From Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Using the IP Address for Remote Switch Management . . . . . . . . . . . . . . . . 3-5
Starting a Telnet Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Starting a Web Browser Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
4 Troubleshooting
Basic Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Diagnosing with the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Proactive Networking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Hardware Diagnostic Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
v
Testing the Switch by Resetting It . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Checking the Switch LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Checking Console Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Testing Twisted-Pair Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Testing Switch-to-Device Network Communications . . . . . . . . . . . . 4-10
Testing End-to-End Network Communications . . . . . . . . . . . . . . . . . 4-10
Restoring the Factory Default Configuration . . . . . . . . . . . . . . . . . . . . . . . 4-11
Downloading New Switch Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
HP Customer Support Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Before Calling Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
A Switch Specifications
Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Acoustic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Cable Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Lasers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
B Switch Ports and Network Cables
Switch Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Twisted-Pair Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Fiber-Optic Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
Mode Conditioning Patch Cord for Gigabit-LX . . . . . . . . . . . . . . . . . . . . . B-3
Installing the Patch Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
Twisted-Pair Cable/Connector Pin-Outs . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Straight-through Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connections . . . . . . . . . . . . . . . . . . . . B-7
Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Crossover Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connection . . . . . . . . . . . . . . . . . . . . . B-8
Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
vi
Straight-Through Twisted-Pair Cable for
1000 Mbps Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Cable Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
C Safety and EMC Regulatory Statements
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Informations concernant la sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Hinweise zur Sicherheit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3
Considerazioni sulla sicurezza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4
Consideraciones sobre seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-5
Safety Information (Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6
Safety Information (China) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7
EMC Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
U.S.A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Australia/New Zealand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9
Taiwan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-9
European Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-10
Waste Electrical and Electronic Equipment (WEEE) Statements . . . . . C-12
Index
1-1
Introducing the Switch
1
Introducing the Switch
The ProCurve Series 2600 Switches are multiport switches that can be used
to build high-performance switched workgroup networks. These switches are
store-and-forward devices that offer low latency for high-speed networking.
The 2600-PWR Switches also support Redundant Power Supply and Power
over Ethernet (PoE) technologies.
Throughout this manual, these switches will be referred to as the Series 2600
Switches and the Series 2600-PWR Switches.
ProCurve Switch 2650 (J4899B)
ProCurve Switch 2626 (J4900B)
LED
Mode
Cle a rRe s e t Sp d mode: o ff = 10 Mbps, flas h = 100 Mbps, on = 1000 Mbps PoE- Ready 10/100B ase - T X Ports (1 - 48)
G ig - T
Port s
Mini-
G BIC
Port s
1 11 23
12 24 26
25
36
47
48
M M
Powe r
Fault
hp procurve
switch 2650- PWR
J81 65A
PoE
Act
FDx
(all 10/100Base-T X ports are HP Auto-MDIX, Gig -T ports are IEEE Auto MDI/MDI- X)
Link|Mode
Te st
RPS
EPS
Fan
50
St atus
Spd
2
2 4 6 8 10
12
14 16 18
20
22
24
26 28 30 40 4432 34 36 38 42
1 3 5 7 9 11 13 15 17 19 21 31 4123 25 27 29 33 35 37 39 43
49
47
48
45
46
13
14
35 37
38 !Use only one (T o r M) for e ach G iga bit p ort
PoE
ProCurve Switch 2650-PWR (J8165A)
PoE
Power
Fault
Dual- Pe rs onalit y Port :
10/100/1000- T (T) or Mini- G BIC ( M)
(Po rt 9T is IEEE Aut o MDI/MDIX)
St a t us
Re se t C le ar
Con sole
PoE- In t egrat ed 10/100- TX Port s (1 - 8)
 ( Po rt s a re HP Auto- MD IX)
ProCurve
Swit ch
2600- PWR
J8762A
*
Spd mo de: off = 10 Mbps, f la sh = 1 00 Mbps, o n = 1000 Mbps
Li nk
Mod e
LED
Mode
Spd
Act
FDx
Tes t
EPS
Fan
2 3 4
Li nk Mod e
1
Li nk Mod e
5 6 7 8 9T
Li nk M od e
PoE
*
9M
!
Use on ly o ne (T o r M) for Por t 9
RPS
!
Use only one ( T or M) for e ach Gig abit po rt
C le a rRe s et Spd mo de : off = 10 Mbps ,
fla sh = 100 Mbp s, on = 1000 Mbps PoE-Re ady 10/100Bas e - T X Po rts (1 - 24)
Gig- T
Port s
Mini-
GB IC
Port s
1
24
M M
Powe r
Fault
PoE
Act
FDx
(all 10/100Base -TX po rts are HP Auto-MDIX, G ig -T po rts are IEEE Auto MDI/MDI- X)
Link|Mode
Test
RPS
EPS
Fan
26
Stat us
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20
25
23
24
21
22
2 12
231311
14
Spd
hp procurve
switch
2626-PWR
J8164A
LED
Mode
PoE
ProCurve Switch 2626-PWR (J8164A)
ProCurve Switch 2600-8-PWR with Gigabit Uplink (J8762A)
1-2
Introducing the Switch
Introducing the Switch
The Switch 2650 and 2650-PWR, has 48 auto-sensing 10/100Base-TX RJ-
45 ports with two dual-personality Gigabit Uplink ports.
The Switch 2626 and 2626-PWR, has 24 auto-sensing 10/100Base-TX RJ-
45 ports with two dual-personality Gigabit Uplink ports.
The Switch 2600-8-PWR, has 8 auto-sensing 10/100Base-TX RJ-45 ports
with one dual-personality Gigabit Uplink port.
The dual-personality ports are either auto-sensing 10/100/1000Base-T RJ-45,
or mini-GBIC (Small Form Factor Pluggable (SFP) ports in an Ethernet
application).
The Series 2600-PWR Switches incorporate two additional features. These
switches offer two types of power, one for switch AC operating power, and
the other for Power over Ethernet (PoE) power:
Power-over-Ethernet or PoE power - PoE technology allows IP tele-
phones, wireless LAN Access Points and other appliances to receive
power as well as data over existing LAN cabling, without needing to
modify the existing Ethernet infrastructure. The Series 2600-PWR
Switches are designed with an internal PoE power supply capable of
providing 406 watts of PoE power (126 watts on the 2600-8-PWR). All of
the Switch 2600-PWR ports can provide up to 15.4 watts of PoE power to
connected devices. For further information regarding PoE power, see the
PoE Planning and Implementation Guide which is on the documentation
CD that came with the switch.
Redundant and External Power Supply Support - The Series 2600-
PWR Switches can be connected to a ProCurve 600 Redundant and
External Power Supply (J8168A), hereafter referred to as the 600 RPS/
EPS or a ProCurve 610 External Power Supply, hereafter referred to as
the 610 EPS, and receive redundant power from that unit. As an RPS unit,
the 600 RPS/EPS will provide all the AC power necessary to keep the
switch running should the switch internal AC power supply fail.
As an EPS unit, the 600 RPS/EPS and the 610 EPS can supply up to 408
watts of PoE power to the switch if the internal PoE power supply of the
switch should fail. When used with the Switch 2650-PWR, the additional
EPS power can provide up to 15.4 watts per port for 48 ports. For further
information regarding the 600 RPS/EPS or the 610 EPS PoE capabilities,
see the PoE Planning and Implementation Guide, which is on the
documentation CD that came with the switch.
With these switches you can directly connect computers, printers, and servers
to provide dedicated bandwidth to those devices, and you can build a switched
network infrastructure by connecting the switch to hubs, other switches, or
routers. In addition, the Series 2600 Switches offer full network management
capabilities.
1-3
Introducing the Switch
Front of the Switch
Introducing the Switch
Front of the Switch
Port LED View select
button and indicator LEDs
Switch port LEDs
Self Test and Fan
Status LEDs
10/100Base-TX RJ-45 ports1 Dual-personality ports
(1000Base-T2 or mini-GBIC)
ProCurve Switch 2650
Power
and Fault
LEDs
Reset and Clear
buttons
LED
Mode
Cle a rRe s e t Sp d mo de: o ff = 10 Mbps ,
flash = 100 Mbps, on = 1000 Mbps PoE- Ready 10/100Bas e -TX Ports (1 - 48)
G ig - T
Port s
Mini-
G BIC
Port s
1 11 23
12 24 26
25
36
47
48
M M
Powe r
Fault
hp procurve
switch
2650-PWR
J81 65A
PoE
Act
FDx
(all 10/100Base - T X po rts are HP Auto-MDIX, Gig- T po rts are IEEE Auto MDI/MDI-X)
Link|Mo de
Te st
RPS
EPS
Fan
50
St atus
Spd
2
2 4 6 8 10
12
14 16 18
20
22
24
26 28 30 40 4432 34 36 38 42
1 3 5 7 9 11 13 15 17 19 21 31 4123 25 27 29 33 35 37 39 43
49
47
48
45
46
13
14
35 37
38
!
Use only one (T o r M) fo r e ach Gig abit p ort
PoE
Switch port LEDs
Reset and Clear
buttons
Dual-personality ports
(1000Base-T2 or mini-GBIC)
ProCurve Switch 2650-PWR
Power
and Fault
LEDs
RPS, EPS, Fan and
Test Status LEDs
10/100Base-TX RJ-45 ports1
LED Mode select button
and indicator LEDs
Po E
Power
Fault
Dual- Personality Port:
10/100/1 000- T (T) or Mini- GBIC ( M)
(Port 9T is IEEE A ut o MD I/MDIX)
St at u s
Res et C le a r
Cons ole
PoE- Integrated 10/100- TX Ports (1 - 8)
 (Po rt s are HP Aut o- MDIX)
ProCurve
Switch
2600 - PWR
J8762A
*
Spd mo de: o ff = 10 Mbps , f las h = 100 Mbp s, o n = 1000 Mbps
Lin k
Mo de
LED
Mode
Spd
Act
FDx
Tes t
EPS
Fan
2 3 4
Lin k Mo de
1
Lin k Mo de
5 6 7 8 9T
Lin k Mo de
PoE
*
9M
!
Use o nly on e (T or M) for P o rt 9
RPS
10/100Base-TX RJ-45 ports1
ProCurve Switch 2600-8-PWR
Switch port LEDs
Reset and Clear
buttons
1
All 10/100Base-TX RJ-45 ports have the HP Auto MDIX feature.
2
10/100/1000Base-T ports have the IEEE Auto MDI/MDI-X feature.
Power
and Fault
LEDs
RPS, EPS, Fan and
Test Status LEDs
LED Mode select button
and indicator LEDs
Console Port
Dual-personality port
(1000Base-T2 or mini-GBIC)
1-4
Introducing the Switch
Front of the Switch
Introducing the Switch
Network Ports
8, 24, or 48 auto-sensing 10/100Base-TX ports.
All these ports have the “HP Auto MDIX” feature, which means that you
can use either straight-through or crossover twisted-pair cables to
connect any network devices to the switch.
Dual-personality ports. You can use either the 10/100/1000Base-T RJ-45
connector, or install a supported ProCurve mini-GBIC for fiber-optic
connections. The RJ-45 connectors support the IEEE Auto MDI/MDI-X
feature, which operates the same as the “HP Auto-MDIX” feature.
By default, the RJ-45 connectors are enabled. If a mini-GBIC is installed,
it is enabled and the associated RJ-45 connector is disabled and cannot
be used. If the mini-GBIC is removed, the associated RJ-45 port is
automatically re-enabled.
LEDs
On the Series 2600 Switches, there are three groupings of LEDs:
switch status LEDs (Table 1-1)
port LEDs (Table 1-2)
Port LED View (non-PWR switches) and LED Mode (PWR switches)
indicator LEDs (near the selector button) (Table 1-3)
Table 1-1. Switch Status LEDs
Switch LEDs State Meaning
Power
(green)
On The switch is receiving power.
Off The switch is NOT receiving power. (Unless and RPS is connected to the
switch. If the switch looses power and the RPS is actively powering the
switch, the Power LED will be off and the switch will still have power and
all other LEDs will be functional.)
Fault
(orange)
Off The normal state; indicates there are no fault conditions on the switch.
Blinking1A fault has occurred on the switch, one of the switch ports, the fan, or the
RPS or EPS operation of the switch. The Status LED for the component
with the fault will blink simultaneously.
On On briefly after the switch is powered on or reset, at the beginning of
switch self test. If this LED is on for a prolonged time, the switch has
encountered a fatal hardware failure, or has failed its self test. See
chapter 4, “Troubleshooting” for more information.
1-5
Introducing the Switch
Front of the Switch
Introducing the Switch
See the ProCurve 600/610 External Power Supplies Installation and Getting
Started Guide for information on the LED behavior of the external power
supplies.
Self Test
(green)
labeled “Test
on the PWR
switches
Off The normal operational state; the switch is not undergoing self test.
On The switch self test and initialization are in progress after you have power
cycled or reset the switch. The switch is not operational until this LED
goes off. The Self Test LED also comes on briefly when you “hot swap” a
mini-GBIC into the switch; the mini-GBIC is tested when it is hot swapped.
Blinking1A component of the switch has failed its self test. The status LED for that
component, for example an RJ-45 port, and the switch Fault LED will blink
simultaneously.
Fan Status
(green)
On The cooling fan is operating normally.
Blinking1The cooling fan has failed. The switch Fault LED will be blinking
simultaneously.
RPS Status 2
(green)
On
Blinking
Off
Normal operation. An 600 RPS/EPS unit is connected and operating
correctly. The 600 RPS/EPS could be powering the unit - see table below.
The 600 RPS/EPS is connected but may be powering another switch or
the 600 RPS/EPS has experienced a fault.
The 600 RPS/EPS is not connected or is not powered.
EPS Status 2
(green)
On
Blinking
Off
Connected to an External Power Supply, either an 600 RPS/EPS or an 610
EPS, and receiving PoE power.
The External Power Supply has experienced a fault:
PoE power is oversubscribed (not enough PoE power available).
The software on the ProCurve Series 2600-PWR Switches may not
support the EPS function.
There is a fan, overcurrent, power supply, or temp fault.
The Switch detects the EPS is present but cannot communicate with it.
Check the Error Log on the switch for more information.
The switch is not connected to an External Power Supply or the EPS cable
is connected but the External Power Supply is not powered up.
1 The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
2 ProCurve Series 2600-PWR Switches only.
Switch LEDs State Meaning
1-6
Introducing the Switch
Front of the Switch
Introducing the Switch
Port LEDs
The port LEDs provide information about the individual switch ports.
Table 1-2. Port LEDs
Switch LEDs State Meaning
Switch 2626 and Switch 2650
Port LEDs
(green – over-
laid with the
port number)
Displays port link information, network activity information, whether the port is
configured for full-duplex operation, or the speed of the connection depending on the
Port LED View selected. See “Port LED View Select Button and Indicator LEDs” on the
next page for more information.
Series 2600-PWR Switches
Link
(green - over-
laid with the
port number or
embedded
with the
connector)
On Indicates the port is enabled and receiving a link beat signal (for the
twisted-pair ports), of a strong enough light level (for the fiber-optic ports)
from the connected device.
Off
Blinking1
One of these condition exists:
no active network cable is connected to the port
the port is not receiving link beat or sufficient light
the port has been disabled through the switch console, the web browser
interface, ProCurve Manager, or other network management tool.
The port has failed self test. The switch Fault, and Self Test LEDs will flash
simultaneously.
Mode Depending on the mode selected, displays the following: network activity information,
whether the port is configured for Full Duplex operation, maximum speed operation, or
whether network errors are occurring on the port. See “LED Mode Select Button and
Indicator LEDs:” below for more information.
All Series 2600 Switches 2
T/M
(green)
On For the dual-personality ports, indicates the enabled port:
if the “T” is on, the 10/100/1000Base-T RJ-45 port is enabled.
if the “M” is on, the mini-GBIC port is enabled.
1 The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
2 For the 2600-8-PWR device, both connectors of the dual-personality port have Link and Mode LEDs. To
clearly indicate that the mini-GBIC/SFP port has taken control of port 9, when a mini-GBIC/SFP is fully
inserted into the garage, the Link LED will blink with a slow blink rate on the 9M port to indicate a status
change.
1-7
Introducing the Switch
Front of the Switch
Introducing the Switch
Multiple-Display Port LEDs - Port LED View or
LED Mode Select Button and Indicator LEDs
To optimize the amount of information that can be displayed for each of the
switch ports in the limited space available, the Series 2600 Switches use
multiple-display LEDs for each port.
Port LED View select
button and indicator LEDs
Switch 2626 and Switch 2650
Port LED
(one for each port)
For the non-PWR switches, there is a
single LED per port. The operation of
this LED is controlled by the Port LED
View select button, and the current
setting is indicated by the Port LED
View indicator LEDs near the button.
Press the button to step from one view
mode to the next. The default view is
Link (Lnk).
LED
Mode
ClearReset Spd mode: off = 10 Mbps, flash = 100 Mbps, on = 100
0
1
Power
Fault
hp procurve
switch 2650-PWR
J8165A
PoE
Act
FDx
Test
RPS
EPS
Fan
Status
Spd
2
2 4 6 8 10
1 3 5 7 9
PoE
Link LED
(port number)
LED Mode select button
and indicator LEDs
Switch 2626-PWR and 2650-PWR
Mode LED
For the PWR switches, there are two
LEDs per port. The Link status is
always shown by the Link LED. The
operation of the Mode LED is
controlled by the LED Mode select
button, and the current setting is indi-
cated by the LED Mode indicator LEDs
near the button. Press the button to
step from one view mode to the next.
The default view is Activity (Act).
Switch 2600-8-PWR
Mode LED (Right LED)
Link LED
(Left LED)
For the 2600-8-PWR switch,
the LEDs are embedded in
the port connector. The Link
and Mode LEDs operate the
same as the other PWR
switches (see above).
LED Mode select button
and indicator LEDs
1-8
Introducing the Switch
Front of the Switch
Introducing the Switch
Table 1-3. Multiple-Display Port LEDs
Switch LEDs State Meaning
Switch 2626 and Switch 2650
Port LED View
indicator LEDs
(4 green LEDs)
Lnk
Act
FDx
Spd
Indicates that the Port LEDs are displaying link information:
if the Port LED is on, the port is enabled and receiving a link indication
from the connected device.
if the Port LED is off, the port has no active network cable connected, or
is not receiving signal or sufficient light. Otherwise, the port may have
been disabled through the switch console or the web browser interface.
if the Port LED is blinking
1 simultaneously with the Fault LED, the
corresponding port has failed its self test.
Indicates the Port LEDs are displaying network activity information.
Indicates the Port LEDs are lit for ports that are in full-duplex mode.
Indicates the Port LEDs are displaying the connection speed at which each
port is operating:
if the Port LED is off, the port is operating at 10 Mbps.
if the Port LED is flashing, the port is operating at 100 Mbps.
if the Port LED is on continuously, the port is operating at 1000 Mbps.
Series 2600-PWR Switches
LED Mode
indicator LEDs
(4 green LEDs)
Act
FDx
Spd
PoE
Indicates the Port Mode LEDs are displaying network activity information.
Indicates the Port Mode LEDs are lit for ports that are in full-duplex mode.
Indicates the Port Mode LEDs are displaying the connection speed at which
each port is operating:
if the Port LED is off, the port is operating at 10 Mbps.
if the Port LED is blinking
2, the port is operating at 100 Mbps.
if the Port LED is on continuously, the port is operating at 1000 Mbps.
Indicates the Port Mode LEDs are lit for ports that are providing PoE power
to the connected device.
1 The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
2 The blinking behavior is an on/off cycle once every 0.8 seconds, approximately.
1-9
Introducing the Switch
Front of the Switch
Introducing the Switch
Reset Button
This button is used to reset the switch while it is powered on. This action clears
any temporary error conditions that may have occurred and executes the
switch self test.
Clear Button
This button is used for these purposes:
Deleting Passwords - When pressed by itself for at least one second, the
button deletes any switch console access passwords that you may have
configured. Use this feature if you have misplaced the password and need
console access.
This button is provided for your convenience, but its presence means that
if you are concerned with the security of the switch configuration and
operation, you should make sure the switch is installed in a secure
location, such as a locked wiring closet.
Restoring Factory Default Configuration - When pressed with the
Reset button in a specific pattern, any configuration changes you may
have made through the switch console, the web browser interface, and
SNMP management are removed, and the factory default configuration is
restored to the switch. For the specific method to restore the factory
default configuration, see “Restoring the Factory Default Configuration
on page 11, “Troubleshooting” of this manual.
1-10
Introducing the Switch
Back of the Switch
Introducing the Switch
Back of the Switch
Console
AC power connector
Cooling vent - make sure this is not
obstructed for proper switch operation
Console Port
ProCurve Switch 2626 and 2650 non-PWR
Co ns o le
EPS Input
HP Pro Curve
RPS Input
12V 7.5A
Lin e 50/60 Hz.
100- 240 V~ 7.5 A
Pro Curve RPS InputEPS Redundant Input
Line: 50/60 Hz
100 240 V~
3.3 A ( 3,3 A)
!
Mult iple po wer so urces . Disco nne ct
bot h the AC powe r co rd a nd the RPS ca ble
t o c ompl et ely re move powe r f rom t he uni t .
Cooling vent - make sure this is not
obstructed for proper switch operation
Console Port AC power connector
ProCurve Switch 2626-PWR and 2650-PWR
EPS Input RPS Input
ProCurve Switch 2600-8-PWR
AC power
connector
RPS Input
EPS Input
1-11
Introducing the Switch
Switch Features
Introducing the Switch
Console Port
This port is used to connect a console to a Series 2600 Switch by using the
serial cable supplied with each switch. This connection is described under
“8. (Optional) Connect a Console to the Switch” on page 30 in chapter 2,
“Installing the Series 2600 Switches.” The console can be a PC or workstation
running a VT-100 terminal emulator, or a VT-100 terminal.
Power Connector
The Series 2600 Switches do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-240 volts and either 50 or 60 Hz. There are
no voltage range settings required.
Switch Features
The features of the Series 2600 Switches include:
8, 24, or 48 auto-sensing 10/100Base-TX RJ-45 ports with HP Auto-MDIX.
dual-personality ports—either the auto sensing 10/100/1000Base-T RJ-45
or the mini-GBIC can be used for each port.
Power over Ethernet (PoE) operation—the 2600-PWR Series switches are
IEEE 802.3af compliant and provide up to 15.4W per port to power IP
phones, wireless access points, web cameras, and more. For more infor-
mation, see the POE Planning and Implementation Guide, which is on
the Documentation CD-ROM that is included with your switch.
The 2600-8-PWR switch supports some pre-standard PoE devices, for a
current list see the FAQ page for the 2600-8-PWR Switch, which can be
found on the ProCurve Web site, http://www.procurve.com, Technical
Support, FAQs (all).
plug-and-play networking—all ports are enabled—just connect the
network cables to active network devices and your switched network is
operational.
HP Auto-MDIX on all 10/100 twisted-pair ports, and IEEE 802.3ab Auto
MDI/MDI-X on all 10/100/1000 twisted-pair ports, meaning that all
twisted-pair connections can be made using straight-through
cables. Cross-over cables are not required, although they will also work.
automatic learning of the network addresses in each switch’s 8000-
address forwarding table, (with configurable address aging value).
1-12
Introducing the Switch
Switch Features
Introducing the Switch
automatically negotiated full-duplex operation for the 10/100 and
10/100/1000 RJ-45 ports when connected to other auto-negotiating
devices—the mini-GBIC ports always operate at full duplex.
easy management of the switches through several available interfaces:
console interfacea full featured, easy to use, VT-100 terminal
interface that is especially good for out-of-band switch management
or for Telnet access to the switch.
web browser interface—an easy to use built-in graphical interface
that can be accessed from common web browsers.
ProCurve Manageran SNMP-based, graphical network manage-
ment tool that you can use to manage your entire network.
support for the Spanning Tree Protocol to eliminate network loops
support for up to 30 IEEE 802.1Q-compliant VLANs so you can divide the
attached end nodes into logical groupings that fit your business needs.
support for many advanced features to enhance network performance—
for a description, see the Management and Configuration Guide, which
is on the Documentation CD-ROM included with your switch.
download of new switch software for product enhancements or bug fixes.
2-1
Installing the Switch
2
Installing the Switch
The ProCurve Series 2600 Switches come with an accessory kit that includes
the brackets for mounting the switch in a standard 19-inch telco rack, in an
equipment cabinet, or on a wall. The brackets are designed to allow mounting
the switch in a variety of locations and orientations. Rubber feet are provided
that can be attached so the switch can be securely located on a horizontal
surface.
This chapter shows you how to install your Series 2600 Switches.
Included Parts
The Series 2600 Switches have the following components:
ProCurve Series 2600 Switches Installation and Getting Started Guide
(5991-2165), this manual
ProCurve Manager - CD ROM and booklet
Console cable
Customer Support/Warranty booklet
Accessory kits
Switches 2626 and 2650 Non-PWR
and Switch 2600-8-PWR
Switches 2626-PWR and
2650-PWR
Kit number 5069-6535
Contains:
two mounting brackets
eight 8-mm M4 screws to attach the
mounting brackets to the switch
four 5/8-inch number 12-24 screws to
attach the switch to a rack
four rubber feet
Kit number 5069-5705
Contains:
two mounting brackets 1
eight 8-mm M4 screws to attach the
mounting brackets to the switch
four 5/8-inch number 12-24 screws to
attach the switch to a rack
four rubber feet
1 The mounting brackets in this kit are longer to support the increased depth of the 2626-
PWR and 2650-PWR products.
2-2
Installing the Switch
Included Parts
Installing the Switch
AC power cord, one of the following:
J a p a n P o w e r
C o r d W a r n i n g
Non-PWR Switches
and 2600-8-PWR
PWR Switches 1
Australia/New Zealand
China
Continental Europe
Denmark
Japan
Switzerland
United Kingdom/Hong Kong/Singapore
United States/Canada/Mexico
South Africa
Thailand
Taiwan
8120-6803
8120-8377
8120-6802
8120-6806
8120-6804
8120-6807
8120-8709
8120-6805
8120-8929
8121-0673
8121-0964
8120-6810
8120-8471
8120-6811
8120-6814
8120-6804
8120-6815
8120-6809
8120-2371
8120-8929
8121-0673
8121-0964
1 The cords for the PWR Switches support a higher amperage, except for the 2600-8-PWR.
2-3
Installing the Switch
Installation Procedures
Installing the Switch
Installation Procedures
These steps summarize your switch installation. The rest of this chapter
provides details on these steps.
1. Prepare the installation site (page 2-5). Make sure the physical envi-
ronment into which you will be installing the switch is properly prepared,
including having the correct network cabling ready to connect to the
switch and having an appropriate location for the switch. See page 2-4 for
some installation precautions.
2. Install mini-GBICs (optional—page 2-7). The switch has two slots for
installing mini-GBICs. Depending on where you install the switch, it may
be easier to install the mini-GBICs first. Mini-GBICs can be hot swapped—
they can be installed or removed while the switch is powered on.
3. Verify the switch passes self test (page 2-9). Plug the switch into a
power source and observe that the LEDs on the switchs front panel
indicate correct switch operation.
4. Mount the switch (page 2-11). The Series 2600 Switches can be mounted
in a 19-inch telco rack, in an equipment cabinet, on a wall, or on a
horizontal surface. The Series 2600-PWR Switches may be mounted in
racks and cabinets or on a horizontal surface. The Switch 2626-PWR and
the 2650-PWR must not be wall mounted. The Switch 2600-8-PWR can be
wall mounted. See page 2-18 for wall mounting instructions.
5. Connect power to the switch (page 2-19). Once the switch is mounted,
plug it into the main power source.
6. Connect the network devices (page 2-20). Using the appropriate
network cables, connect the network devices to the switch ports.
7. Connect a 600 RPS/EPS or 610 EPS, (optional—page 2-21). You may
wish to use a 600 RPS/EPS or 610 EPS with your Series 2600-PWR Switch.
To do so you must connect these external power supplies using the RPS
or EPS cables supplied with these devices.
8. Connect a console to the switch (optionalpage 2-30). You may wish
to modify the switchs configuration, for example, to configure an IP
address so it can be managed using a web browser, from an SNMP network
management station, or through a Telnet session. Configuration changes
can be made by using the included console cable to connect a PC to the
switch’s console port.
At this point, your switch is fully installed. See the rest of this chapter if you
need more detailed information on any of these installation steps.
2-4
Installing the Switch
Installation Procedures
Installing the Switch
Installation Precautions
Follow these precautions when installing your ProCurve Series 2600 Switches.
WA R N I N G The rack or cabinet should be adequately secured to prevent it
from becoming unstable and/or falling over.
Devices installed in a rack or cabinet should be mounted as low as
possible, with the heaviest devices at the bottom and progressively
lighter devices installed above.
For safe operation do not install the switch with the back of the
switch (with the fan vents) facing either downward or upward.
Do not wall mount the 2626-PWR or the 2650-PWR switches.
C a u t i o n s Ensure the power source circuits are properly grounded, then use the
power cord supplied with the switch to connect it to the power source.
If your installation requires a different power cord than the one supplied
with the switch, ensure the cord is adequately sized for the switch’s
current requirements. In addition, be sure to use a power cord displaying
the mark of the safety agency that defines the regulations for power cords
in your country. The mark is your assurance that the power cord can be
used safely with the switch. If the PWR device’s supplied power cord does
not fit, contact HP.
When installing the switch, the AC outlet should be near the switch and
should be easily accessible in case the switch must be powered off.
Ensure the switch does not overload the power circuits, wiring, and over-
current protection. To determine the possibility of overloading the supply
circuits, add together the ampere ratings of all devices installed on the
same circuit as the switch and compare the total with the rating limit for
the circuit. Maximum ampere ratings are usually printed on the devices
near the AC power connectors.
Do not install the switch in an environment where the operating ambient
temperature might exceed 55 °C (131 °F), if using a 2600 switch, or 50 °C
(122 °F) if using a 2600-PWR switch.
Ensure the air flow around the sides and back of the switch is not
restricted. Leave at least 7.6 cm (3 inches) for cooling. If this unit is placed
in a fully-enclosed rack make certain the ambient temperature inside the
rack near the switch does not exceed 55 °C (if using a 2600 switch) or
50 °C (if using a 2600-PWR switch).
2-5
Installing the Switch
Installation Procedures
Installing the Switch
1. Prepare the Installation Site
Cabling Infrastructure - Ensure the cabling infrastructure meets the
necessary network specifications. See the following table for cable types
and lengths, and see appendix B, “Switch Ports and Network Cables for
more information:
Table 2-1. Summary of Cable Types to Use With the Switch
Port Type Cable Type Length Limits
Twisted-Pair Cables
10/100/1000Base-T For either 10, 100 Mbps, or 1000 Mbps
operation:
Category 5 or better, 100-ohm UTP or shielded
twisted-pair (STP) balanced cable. For
1000 Mbps (gigabit) operation, Category 5e
cabling or better is recommended.
100 meters
Note: The Series 2600 Switches are
compatible with the IEEE 802.3ab standard
including the “Auto MDI/MDI-X” feature,
which allows use of either straight-through or
crossover twisted-pair cables for connecting
to any network devices including end nodes,
such as computers, or to other switches, hubs,
and routers.
Note: For 1000 Mbps operation, all four wire
pairs are used for data transmission, therefore
PoE is not supported for 1000 Mbps operation.
2-6
Installing the Switch
Installation Procedures
Installing the Switch
Installation Location - Before installing the switch, plan its location and
orientation relative to other devices and equipment:
In the front of the switch, leave at least 7.6 cm (3 inches) of space for
the twisted-pair and fiber-optic cabling.
In the back of the switch, leave at least 3.8 cm (1 1/2 inches) of space
for the power cord.
On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling.
Fiber Optic Cables
Gigabit-SX
(on Gigabit-SX-LC
mini-GBIC)
Multimode fiber-optic cables fitted with LC
connectors
220 meters to 550 meters depending on the
cable used. See Fiber-Optic Cables” on page
B-2 for more information.
Gigabit-LX
(on Gigabit-LX-LC
mini-GBIC)
Single-mode fiber-optic cables fitted with LC
connectors.
The multimode cables specified for the Gigabit-
SX mini-GBIC may also be used, but a mode-
conditioning patch cord may be needed see
“Mode Conditioning Patch Cord for Gigabit-LX”
on page B-3 for more information.
single-mode cable = 10 kilometers
multimode cable = 550 meters
Gigabit-LH
(on Gigabit-LH-LC
mini-GBIC)
The same single-mode fiber-optic cables as for
Gigabit-LX.
70 kilometers
Note:
Gigabit-LH - Between the transmit and receive ends of the cable, at least 5db of attenuation is required for a reliable
connection. This is equivalent to 20Km of the fiber-optic cable. For distances less than 20Km, you must add attenuators
to bring the total attenuation to at least 5db. Most cable vendors carry attenuators.
Port Type Cable Type Length Limits
2-7
Installing the Switch
Installation Procedures
Installing the Switch
2. Installing or Removing mini-GBICs
You can install or remove a mini-GBIC from a mini-GBIC slot without having
to power off the switch. Use only ProCurve mini-GBICs.
N o t e s The mini-GBIC slots are shared with the two 10/100/1000Base-T RJ-45
ports. If a mini-GBIC is installed in a slot, the associated RJ-45 port is
disabled and cannot be used.
The mini-GBIC ports operate only at full duplex. Half duplex operation is
not supported.
Ensure the network cable is NOT connected when you install or remove
a mini-GBIC.
When this manual was printed, the supported mini-GBICs include the
following:
ProCurve Gigabit-SX-LC mini-GBIC (J4858A and J4858B)
ProCurve Gigabit-LX-LC mini-GBIC (J4859A and J4859B)
ProCurve Gigabit-LH-LC mini-GBIC (J4860A and J4860B)
C a u t i o n Use only supported genuine ProCurve mini-GBICs with your switch. Non-
ProCurve mini-GBICs are not supported, and their use may result in product
malfunction. Should you require additional ProCurve mini-GBICs, contact
your ProCurve Networking Sales and Service Office or authorized dealer.
Installing the mini-GBICs:
Remove the protective plastic cover and retain it for later use. Hold the mini-
GBIC by its sides and gently insert it into either of the slots on the switch until
the mini-GBIC clicks into place.
WA R N I N G The ProCurve mini-GBICs are Class 1 laser devices. Avoid direct eye
exposure to the beam coming from the transmit port.
48
47
46
4543 4442
41
40
39
38
37
G ig -T
Port s
Mini -
G BIC
Ports
47
48
50
49
TMTM
Us e only o ne ( T o r M) fo r e ac h G igab it p ort
!
2-8
Installing the Switch
Installation Procedures
Installing the Switch
Removing the mini-GBICs
N o t e You should disconnect the network cable from the mini-GBIC before removing
it from the switch.
Depending on when you purchased your ProCurve mini-GBIC, it may have
either of three different release mechanisms: a plastic tab on the bottom of
the mini-GBIC, a plastic collar around the mini-GBIC, or a wire bail.
To remove the mini-GBICs that have the plastic tab or plastic collar, push the
tab or collar toward the switch until you see the mini-GBIC release from the
switch (you can see it move outward slightly), and then pull it from the slot.
To remove the mini-GBICs that have the wire bail, lower the bail until it is
approximately horizontal, and then using the bail, pull the mini-GBIC from the
slot.
Replace the protective plastic cover on the mini-GBIC.
2-9
Installing the Switch
Installation Procedures
Installing the Switch
3. Verify the Switch Passes Self Test
Before mounting the switch in its network location, you should first verify it
is working properly by plugging it into a power source and verifying it passes
its self test.
1. Connect the power cord supplied with the switch to the power connector
on the back of the switch, and then into a properly grounded electrical
outlet.
N o t e The Series 2600 Switches do not have a power switch. They are powered on
when the power cord is connected to the switch and to a power source. For
safety, the power outlet should be located near the switch installation.
The switch automatically adjusts to any voltage between 100-240 volts and
either 50 or 60 Hz. There are no voltage range settings required.
If your installation requires a different power cord than the one supplied with
the switch, be sure the cord is adequately sized for the switchs current
requirements. In addition, be sure to use a power cord displaying the mark of
the safety agency that defines the regulations for power cords in your country.
The mark is your assurance that the power cord can be used safely with the
switch. If the PWR devices supplied power cord does not fit, contact HP.
Console
Connect power cord to
the power connector
2626 and 2650 non-PWR switches
Cons o le
EPS Input
HP ProCurve
RPS Inp ut
12V 7.5A
Line 50/60 Hz.
100-240 V~ 7.5 A
2626 PWR and 2650 PWR switches
Connect power cord to
the power connector
2-10
Installing the Switch
Installation Procedures
Installing the Switch
2. Check the LEDs on the switch as described below.
When the switch is powered on, it performs its diagnostic self test. Self test
takes approximately 50 seconds to complete.
LED Behavior
During the self test:
Initially, all the switch and port LEDs are on. Most of the LEDs go off
and then may come on again during phases of the self test.
For the duration of the self test, the Self Test LED stays on.
Self Test LED Switch port LEDs
Power and
Fault LEDs
Switch 2650
Switch 2650-PWR
LED
Mode
ClearReset Spd mode: off = 10 Mbps, flash = 100 Mbps, on = 1000 Mbps PoE-Ready 10/100Base-TX Ports (1 - 48)
1 11 23
12 24
Power
Fault
hp procurve
switch
2650-PWR
J8165A
PoE
Act
FDx
Link|
M
Test
RPS
EPS
Fan
Status
Spd
2
2 4 6 8 10
12
14 16 18
20
22
24
1 3 5 7 9 11 13 15 17 19 21 23
13
14
PoE
Test LED
2-11
Installing the Switch
Installation Procedures
Installing the Switch
When the self test completes successfully:
The Power and Fan Status LEDs remain on.
The Fault and Self Test LEDs go off.
The port LEDs on the front of the switch go into their normal opera-
tional mode:
If the ports are connected to active network devices, the LEDs
behave according to the Port LED View or LED Mode selected.
For the non-PWR switches, in the default view mode (Link), the
LEDs should be on. For the PWR switches, with two LEDs per
connections, the Link LEDs will be on and the Mode LEDs will
flicker if there is network activity.
If the ports are not connected to active network devices, the Link
and Activity LEDs will stay off.
If the LED display is different than what is described above, especially if
the Fault and Self Test LEDs stay on for more than 60 seconds or they start
blinking, the self test has not completed correctly. Refer to chapter 4,
“Troubleshooting” for diagnostic help.
4. Mount the Switch
After the switch passes self test, it is ready to be mounted in a stable location.
The Series 2600 Switches can be mounted in these ways:
1 The 2600-8-PWR switch can be wall mounted. See page 2-18 for instructions.
Rack or Cabinet Mounting
The Series 2600 Switches are designed to be mounted in any EIA-standard 19-
inch telco rack or communication equipment cabinet. Note that the mounting
brackets have multiple mounting holes and can be rotated allowing for a wide
variety of mounting options. Secure the rack in accordance with the
manufacture’s safety guidelines.
W A R N I N G For safe operation, please read the mounting precautions on
page 2-4, before mounting a switch.
Mounting Location Non-PWR Switches PWR Switches
In a rack or cabinet Yes Yes
On a horizontal surface Yes Yes
On a wall Yes No1
2-12
Installing the Switch
Installation Procedures
Installing the Switch
E q u i p m e n t
C a b i n e t
N o t e
The 12-24 screws supplied with the switch are the correct threading for
standard EIA/TIA open 19-inch racks. If installing the switch in an equipment
cabinet such as a server cabinet, use the clips and screws that came with the
cabinet in place of the 12-24 screws that are supplied with the switch.
Rack Mounting the 2626-PWR and 2650-PWR switches
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 8-mm M4 screws.
W A R N I N G For safe reliable installation, only use the screws provided in the
accessory kit to attach the mounting brackets to the switch.
2-13
Installing the Switch
Installation Procedures
Installing the Switch
N o t e The mounting brackets have multiple mounting holes and can be rotated
allowing for a wide variety of mounting options. These include mounting the
switch so that its front face is flush with the face of the rack, or mounting it
in a more balanced position as shown in the illustration above.
2. Hold the switch with attached brackets up to the rack and move it
vertically until rack holes line up with the bracket holes, then insert and
tighten the four number 12-24 screws holding the brackets to the rack.
2-14
Installing the Switch
Installation Procedures
Installing the Switch
Rack Mounting the Non-PWR Switches
and the 2600-8-PWR Switch
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 8-mm M4 screws.
N o t e The mounting brackets have multiple mounting holes and can be rotated
allowing for a wide variety of mounting options. These include mounting the
switch so that its front face is flush with the face of the rack, or mounting it
in a more balanced position as shown in the illustration.
WA R N I N G For safe reliable installation, only use the screws provided in the
accessory kit to attach the mounting brackets to the switch.
8 mm
M4 screws
2-15
Installing the Switch
Installation Procedures
Installing the Switch
2. Hold the switch with attached brackets up to the rack and move it
vertically until rack holes line up with the bracket holes, then insert and
tighten the four number 12-24 screws holding the brackets to the rack.
Install 12-24
screws
2-16
Installing the Switch
Installation Procedures
Installing the Switch
Flat Wall Mounting
You can mount the Non-PWR switches on a wall as shown in the illustration
on the next page. However, this is not supported for the 2626-PWR or the 2650-
PWR switches. Wall mounting the PWR switches is not supported because of
the size and weight of the devices. Wall mounting the 2600-8-PWR switch is
supported. See page 2-18 for instructions.
WA R N I N G For safe operation do not install the switch with the back face of the
switch (with the fan vents) facing either downward or upward. Do not
wall mount the 2626-PWR or the 2650-PWR switches.
C a u t i o n The switch should be mounted only to a wall or wood surface that is at least
1/2-inch (12.7 mm) plywood or its equivalent.
Supported Wall Mounting Positions.
Switch Vertical Wall Mounting Horizontal Wall Mounting
2626 Non-PWR Yes No
2650 Non-PWR Yes No
2626-PWR No No
2650-PWR No No
2600-8-PWR No Yes
2-17
Installing the Switch
Installation Procedures
Installing the Switch
Wall mounting the Series 2600 Non-PWR Switches
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to opposite corners of the switch with the included 8-mm M4
screws.
2. Attach the switch to the wall or wood surface with two 5/8-inch (15.875
mm) number 12 wood screws (not included).
W A R N I N G The Switch 2626-PWR or 2650-PWR Switches are not wall mountable.
For “Flat” Wall Mounting (Vertical)
M4 screws
The brackets are attached on
opposite corners to improve the
stability of the switch on the wall.
5/8-inch
wood screws
Wall
2-18
Installing the Switch
Installation Procedures
Installing the Switch
Wall mounting the Series 2600-8-PWR Switch
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 8-mm M4 screws.
2. Attach the switch to the wall or wood surface with two 5/8-inch number
12 wood screws (not included).
C a u t i o n The 2600-8-PWR switch can only be wall mounted either with the RJ-45 ports
side up or down (horizontally). A vertical wall mount orientation is not
supported.
For “Flat” Wall Mounting (Horizontal)
M4 screws
5/8-inch
wood screws
Wall
RJ-45 Ports
2-19
Installing the Switch
Installation Procedures
Installing the Switch
Horizontal Surface Mounting
Place the switch on a table or other horizontal surface. The switch comes with
rubber feet in the accessory kit that can be used to help keep the switch from
sliding on the surface.
Attach the rubber feet to the four corners on the bottom of the switch within
the embossed angled lines. Use a sturdy surface in an uncluttered area. You
may want to secure the networking cables and switch power cord to the table
leg or other part of the surface structure to help prevent tripping over the
cords.
C a u t i o n Ensure the air flow is not restricted around the sides and back of the switch.
5. Connect the Switch to a Power Source
1. Plug the included power cord into the switch’s power connector and into
a nearby AC power source.
2. Re-check the LEDs during self test. See “LED Behavior” on page 2-10.
2-20
Installing the Switch
Installation Procedures
Installing the Switch
6. Connect the Network Cables
Connect the network cables, described under “Cabling Infrastructure” (page
2-5), from the network devices or your patch panels to the fixed RJ-45 ports
on the switch or to any mini-GBICs you have installed in the switch.
Using the RJ-45 Connectors
To connect:
Push the RJ-45 plug into the RJ-45
port until the tab on the plug clicks
into place. When power is on for the
switch and for the connected device,
the Link LED for the port should light
to confirm a powered-on device (for
example, an end node) is at the other
end of the cable.
If the Link LED does not go on when
the network cable is connected to the
port, see “Diagnosing With the LEDs”
in chapter 4, “Troubleshooting”.
To disconnect:
Press the small tab on the plug and
pull the plug out of the port.
Port
LED
View
Se lf
Te st
C le a re se t
Fan
Status
45
6
Spd mode : of f = 10 Mbps, flash
=
1
hp procurve
switch
2650
J4899A
123
Spd
Lnk
Act
FDx
RJ-45 connector
Unshielded twisted-pair cable:
• Category 3, 4, or 5 for 10 Mbps ports
• Category 5 or better for 100 Mbps ports
• Category 5e or better for 1000 Mbps ports
Maximum distance: 100 meters
2-21
Installing the Switch
Installation Procedures
Installing the Switch
Connecting Cables to mini-GBICs
N o t e The mini-GBIC slots are shared with the two 10/100/1000Base-T RJ-45 ports.
If a mini-GBIC is installed in a slot, the associated RJ-45 port is disabled.
If you have any mini-GBICs installed in the switch, the type of network
connections you will need to use depends on the type of mini-GBICs you have
installed. See the table on page 2-5, and appendix B, “Switch Ports and
Network Cables”, for the mini-GBIC cabling information.
For mini-GBICs ports, and in general for all the switch ports, when a network
cable from an active network device is connected to the port, the port LED
for that port should go on. If the port LED does not go on when the network
cable is connected to the port, see “Diagnosing with the LEDs in chapter 4,
“Troubleshooting”.
7. (Optional) Connect a Redundant Power Supply
to a Series 2600-PWR Switch
The ProCurve 600 Redundant and External Power Supply, (J8168A), hereafter
referred to as the 600 RPS/EPS, is an accessory product for the Series 2600-
PWR Switches and specific other ProCurve switches. The 600 RPS/EPS
provides two types of power to the switches:
Redundant power to one of up to six switches, to back up the internal
switch power supply in case of AC power loss, or a fault condition. Should
the internal switch power supply fail, power will be supplied from the 600
RPS/EPS, if it is available, that is, if the 600 RPS/EPS is not already
providing power to a higher priority switch. See the documentation that
came with your 600 RPS/EPS for more information.
External Power-over-Ethernet (PoE) power to up to two switch products.
The 600 RPS/EPS can supply 408 watts of PoE power to the switch if the
internal PoE power supply should fail. For the Switch 2650-PWR the
external PoE power is additional power made available to the switch’s
ports. For further information regarding the 600 RPS/EPS PoE
capabilities, see the PoE Planning and Implementation Guide and the
ProCurve 600/610 External Power Supplies Installation and Getting
Started Guide, which is on the Documentation CD-ROM that came with
your switch.
The 600 RPS/EPS is an unmanaged power supply that only provides
information by way of LEDs.
2-22
Installing the Switch
Installation Procedures
Installing the Switch
RPS/EPS Operation
The RPS/EPS monitors the power signal from the switch by detecting that the
RPS/EPS is connected to a switch with an RPS/EPS cable. When the power
from the switch is no longer detected, the RPS/EPS will turn on and provide
power to the switch within 1 millisecond.
The RPS/EPS supports hot plugging of the RPS/EPS cable without causing a
reboot of the switch or causing the power supply in either the RPS/EPS or
switch to shut down temporarily or permanently. For more information refer
to the documentation that came with the RPS/EPS.
Operating Characteristics of the 600 RPS/EPS (J8168A)
The 600 RPS/EPS has six RPS ports, each of which can provide redundant
+12V power to a connected switch, but only one connector can provide this
power at a given time.
If a switch with no AC power is connected to an operating 600 RPS/EPS, it
will receive power if power is available (no higher priority port is already using
the RPS power).
If two or more devices fail, priority goes to the device plugged into the lower
numbered port on the 600 RPS/EPS unit. Consequently the most important
switch should be plugged into port one on the 600 RPSEPS. In this state, the
“Connected” LED should be ON, and the “Power Status” LED should be
BLINKING on the lower priority RPS port not supplying power. (Refer to the
documentation that came with your 600 RPS/EPS unit.)
The 600 RPS/EPS also has two EPS Ports. The 600 RPS/EPS can provide a
maximum of 408 watts of PoE power to a switch. It is important to understand
the PoE power requirements of the 2600-PWR Series switches because if the
PoE power is not planned and implemented correctly the end devices
connected to the switch ports may not receive power if an internal switch PoE
power supply should fail. For further information regarding the 600 RPS/EPS
PoE capabilities, see the PoE Planning and Implementation Guide and the
ProCurve 600/610 External Power Supplies Installation and Getting Started
Guide, which is on the Documentation CD-ROM that came with your switch.
For redundant AC power, connect the 600 RPS/EPS to the switch using one
of the six supplied RPS cables. RPS cables are 1.25 meters (4.10 feet) in length.
For redundant or additional PoE power, connect the 600 RPS/EPS to the
switch using one of the two supplied EPS cables. EPS cables are 2.00 meters
(6.56 feet) in length.
2-23
Installing the Switch
Installation Procedures
Installing the Switch
600 RPS/EPS LEDs
The 600 RPS/EPS LEDs are located on the back of the device. These LEDs are
duplicated on the front of the device for your convenience. The following
graphic shows an example of the back of the 600 EPS/RPS. There are two
green LEDs for each RPS and EPS port:
Device Connected
Power Status
The following states provide status of the RPS and EPS ports.
R3 R4 R5 R6 E1 Device
Connected
Pow er
Status
E2
RPS 3 RPS 4 RPS 5 RPS 6 EPS 1 EPS 2
EPS Power: 50V 370W total for PoE applications. Power is shared when both ports are used.
R
PS Power: 12V backup to one connected device. Lowest-numbered port has priority.
Line: 50/60 Hz.
10 0 - 240 V~ 9.1A (9,1A)
!
RPS Power Status LED EPS Device Connected LED EPS Power Status LED
RPS Device Connected LED
Fault (located on
the front)
Device
Connected
Power
Status
Message
Off Off Off Nothing Connected
On or Off Off On Not a valid state - should never happen
Off On Off Switch is connected, RPS is available but
not required
Off On On RPS is powering the connected device
Blinking Off Blinking RPS/EPS port is in fault condition
Off On Blinking Switch is requesting power, RPS can not
provide it. (N/A for EPS)
2-24
Installing the Switch
Installation Procedures
Installing the Switch
600 RPS/EPS Connectivity
The following illustration shows an example of connectivity between an RPS/
EPS device and a switch device as a redundant AC power supply.
Device Connected
Power Status
R1 R2 R3 R4 R5 R6 E1
Device
Connected
Pow er
Status
E2
RPS 1 RPS 2 RPS 3 RPS 4 RPS 5 RPS 6 EPS 1 EPS 2
EPS Power: 50V 370W total for PoE applications. Power is shared when both ports are used.RPS Power: 12V backup to one connected device. Lowest-numbered port has priority.
Line: 50/60 Hz.
10 0 -2 40 V~ 9.1A (9,1A)
Console
!
Line 50/60 Hz.
100-240 V~ 7.5 A
EPS Input
HP ProCurve
RPS Input
12V 7.5A
RPS input port
Switch RPS output port
2-25
Installing the Switch
Installation Procedures
Installing the Switch
The following illustration shows an example of connectivity between an RPS/
EPS device and six switch devices as a redundant AC power supply.
The 600 RPS/EPS can provide backup power for up to six switches. The 600
RPS/EPS can supply power to only one connected and failed switch at a time.
In the illustration above, the switch connected to RPS port 1 has the highest
priority and the switch connected to RPS port 6 has the lowest priority. When
multiple switches fail, a switch connected to a higher priority port always
receives power before a switch connected to a lower priority port.
2650-PWR switches
600 RPS/EPS
Highest priority
connected to port 1
2-26
Installing the Switch
Installation Procedures
Installing the Switch
The following illustration demonstrates an example of connectivity between
an RPS/EPS device and a Switch device as a PoE power supply.
Device Connected
Power Status
R1 R2 R3 R4 R5 R6 E1
Device
Connected
Pow er
Status
E2
RPS 1 RPS 2 RPS 3 RPS 4 RPS 5 RPS 6 EPS 1 EPS 2
EPS Power: 50V 370W total for PoE applications. Power is shared when both ports are used.RPS Power: 12V backup to one connected device. Lowest-numbered port has priority.
Line: 50/60 Hz.
10 0 -2 40 V~ 9.1A (9,1A)
Console
EPS Input
HP ProCurve
RPS Input
12V 7.5A
Line 50/60 Hz.
100-240 V~ 7.5 A
Switch EPS output
EPS input port
2-27
Installing the Switch
Installation Procedures
Installing the Switch
610 EPS LEDs
For a complete description of the LEDs see the documentation that came with
the 610 EPS.
Operating Characteristics of the 610 EPS (J8169A)
The 610 EPS does not have any RPS ports and can not supply RPS power. It
has four EPS Ports. Two in Pair A and two in Pair B. Each pair can provide a
maximum of 408 watts of PoE power to a switch. Again, it is important to
understand the PoE power requirements of the switches. For further
information regarding the 610 EPS PoE capabilities, see the PoE Planning
and Implementation Guide, which is on the Documentation CD-ROM that
came with your switch and the documentation that came with the 610 EPS.
For redundant or additional PoE power, connect the 610 EPS to the switch
using one of the four supplied EPS cables. EPS cables are 2.00 meters (6.56
feet) in length.
The following illustration demonstrates and example of connectivity between
a 610 EPS device and two Switch devices as a PoE power supply.
Power
Fault
hp procurve
610 eps
J8169A
Fan/Temp Status flash = Temperature too high
Fan/Temp Status + Fault flash = Fan failure
Fan/Temp Status
Internal Power Status
In Ready Out Ready
Backup Power Ports Status
EPS Ports Pair A
(
408 W total for PoE applications )
EPS Ports: 50V 8.3A max each.
EPS A1
Power
Status
A2 B1 B2A1
Device
Connected
EPS A2 EPS B1
Power
Status
Device
Connected
EPS B2
EPS Ports Pair B
(408 W total for PoE applications )
Power and
Fault LEDs
610 EPS
Internal Power
Status LED
Fan/Temp
Status LED
Backup Power
Port LEDs EPS Port LEDs
Device Connected
LED
Power Status
LED
2-28
Installing the Switch
Installation Procedures
Installing the Switch
In this example each switch receives 408 watts of PoE power. Each switch is
connected to one port of each pair. If the two switches were connected to both
ports of a pair, both ports of pair A for example, then each switch receives 204
watts. See the following example.
The following illustration demonstrates an example of connectivity between
a 610 EPS device and four Switch devices as a PoE power supply. In this
example each switch receives 204 watts of PoE power.
Power
Fault
hp procurve
610
eps
J8169A
Fan/Temp Status flash = T emperatu re too hi gh
Fan/Temp Status + F ault flash = Fan failu re
Fan/T emp Statu s
Internal Power Sta tus
In R eady Out R eady
Backup Power Ports Sta tus
EPS Ports Pair A
(408 W total for PoE appli cations)
EPS Po rt s: 50V 8.3A ma x ea ch.
EPS A1
Power
Status
A2 B1 B2A1
Device
Conne cted
EPS A2 EPS B1
Power
Status
Device
Conne cted
EPS B2
EPS Ports Pair B
(
408 W total for PoE appl ication s )
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
2-29
Installing the Switch
Installation Procedures
Installing the Switch
Power
Fault
hp procurve
610
eps
J8169A
Fan/Temp Status flash = Temperaturetoo high
Fan/Temp Status + Faultflash = Fan failure
Fan/Temp Status
Internal Power Status
In Ready Out Ready
Backup Power Ports Status
EPS Ports Pair A
(408 W total for PoE applications )
EPS Ports: 50V 8.3A max each.
EPS A1
Power
Status
A2 B1 B2A1
Device
Connected
EPS A2 EPS B1
Power
Status
Device
Connected
EPS B2
EPS Ports Pair B
(408 W total for PoE applications )
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
100-240 V~ 7.5 A
Line: 50/60 Hz.
50 V 16 A
RPS
12 V 7.5 A
2-30
Installing the Switch
Installation Procedures
Installing the Switch
8. (Optional) Connect a Console to the Switch
The Series 2600 Switches have a full-featured, easy to use console interface
for performing switch management tasks including the following:
monitor switch and port status and observe network activity statistics
modify the switch’s configuration to optimize switch performance,
enhance network traffic control, and improve network security
read the event log and access diagnostic tools to help in troubleshooting
download new software to the switch
add passwords to control access to the switch from the console, web
browser interface, and network management stations
The console can be accessed through these methods:
Out-of-band: The Series 2600 Switches come with a serial cable for
connecting a PC or VT-100 terminal, to be used as a console, directly to
the switch.
In-Band: Access the console using Telnet from a PC or UNIX station on
the network, and a VT-100 terminal emulator. This method requires that
you first configure the switch with an IP address and subnet mask by using
either out-of-band console access or through DHCP/Bootp. For more
information on IP addressing and on starting a Telnet session, see
chapter 3, “Configuring the Switch”, in the Management and
Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
The Series 2600 Switches can simultaneously support one out-of-band console
session through the Console Port and in-band Telnet console sessions.
Terminal Configuration
To connect a console to the switch, configure the PC terminal emulator as a
DEC VT-100 (ANSI) terminal or use a VT-100 terminal, and configure either
one to operate with these settings:
any baud rate from 1200 to 115200 (the switch senses the speed)
8 data bits, 1 stop bit, no parity, and flow control set to Xon/Xoff
for the Windows Terminal program, also disable (uncheck) the “Use
Function, Arrow, and C trl Keys for Windows” option
for the Hilgraeve HyperTerminal program, select the “Terminal keys”
option for the “Function, arrow, and ctrl keys act as” parameter
If you want to operate the console using a different configuration, make sure
you change the settings on both the terminal and on the switch so they are
compatible. Change the switch settings first, then change the terminal
settings, then reboot the switch and reestablish the console session.
2-31
Installing the Switch
Installation Procedures
Installing the Switch
Direct Console Access
To connect a console to the
switch, follow these steps:
1. Connect the PC or
terminal to the switch’s
Console Port using the
console cable included
with the switch. (If your
PC or terminal has a 25-pin
serial connector, first
attach a 9-pin to 25-pin
straight-through adapter
at one end of the console
cable.)
2. Turn on the terminal or
PC’s power and, if using a
PC, start the PC terminal
program.
3. Press [Enter] two or three times and you will see the copyright page and
the message “Press any key to continue”. Press a key, and you will then
see the switch console command (CLI) prompt, for example:
ProCurve Switch #
If you want to continue with console management of the switch at this time,
see chapter 3, “Getting Started With Switch Configuration” for some basic
configuration steps. For more detailed information, refer to the Management
and Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
Co nso le
Console port
Console cable supplied
with the switch
PC running a terminal
emulator program, or
a VT-100 terminal
2-32
Installing the Switch
Sample Network Topologies for Non-PWR Switches
Installing the Switch
Sample Network Topologies for
Non-PWR Switches
This section shows a few sample network topologies in which the Switch 2650
is implemented. For more topology information, see the ProCurve networking
products Web site, http://www.procurve.com.
As a Desktop Switch
The Series 2600 Switches are designed to be used primarily as desktop
switches to which end nodes, printers, other peripherals, and servers are
directly connected, as shown in the above illustration. The end node devices
are connected to the switch by straight-through or crossover twisted-pair
cables. Either cable type can be used because of the “HP Auto-MDIX” and
“IEEE Auto MDI/MDI-X” features on the Series 2600 Switches.
Switch 2650
PCs and
peripherals
Server
Twisted-pair
straight-through
or crossover
cables
2-33
Installing the Switch
Sample Network Topologies for Non-PWR Switches
Installing the Switch
As a Segment Switch
The Series 2600 Switches also work well as segment switches. That is, with
their high performance, they can be used for interconnecting network
segments—simply connect the network devices that form those segments to
the Series 2600 Switches.
In the illustration above, two “Fast Ethernetswitches with PCs, printers, and
local servers attached, are both connected to a Switch 2650. The devices
attached to the two desktop switches can now communicate with each other
through the switch. They can also all communicate with the server that is
connected to a 1000Base-T port on the switch.
Switch 2650
Server with
Gigabit
Ethernet NIC
Twisted-pair
straight-through
cables to
end nodes
Category 5e twisted-pair straight-through or
crossover cable for 1000 Mbps connection to server
Gigabit
fiber-optic cable
to backbone
Switch 2650 Switch 2650
Twisted-pair straight-through
or crossover cables to hubs
PCs,
printers,
and local
servers
2-34
Installing the Switch
Sample Network Topologies for Non-PWR Switches
Installing the Switch
Because the Series 2600 Switches have the “HP Auto-MDIX and “IEEE Auto
MDI/MDI-X” features, the connections between the switch and the hubs, and
between the switch and end nodes or servers can be through category 5
straight-through or crossover twisted-pair cable. Category 3 or 4 cable can
also be used if the connection is 10 Mbps only. In all cases, the device ports
must be configured to auto negotiate the link characteristics for this feature
to work.
The switch, in turn, can be connected to a network backbone through fiber-
optic cabling connected to a Gigabit-SX, -LX, or -LH mini-GBIC. Now, all the
devices on these network segments can access other network resources that
are connected elsewhere on the network backbone. Always remember when
connecting fiber-optics that all components match in specification.
2-35
Installing the Switch
Sample Network Topologies for Non-PWR Switches
Installing the Switch
Connecting to a Backbone Switch
The simpler desktop and segment networks shown in the previous two
examples can easily be combined and expanded. For example, you could use
an ProCurve Switch 5308xl to interconnect each of your smaller switched
workgroups to form a larger switched network. All the devices in this network
can communicate with each other. For example, with Gigabit-SX Mini-GBICs
installed in a Mini-GBIC Module, in the Switch 5308xl, the entire switched
topology could be connected to a campus backbone, as shown in the
illustration above.
N o t e In the illustration above, the 1000 Mbps fiber-optic connection between the
Switch 2650s and the Switch 5308xl is by way of a Gigabit-SX mini-GBIC
installed in the Switch 2650s connected to a mini-GBIC Module in the 5308xl.
To Gigabit-Ethernet
backbone
Switch 2650
Switch 2650
Gigabit
fiber-optic cables
Switch 5308xl
Switch 2650
Switch 2650
2-36
Installing the Switch
Sample Network Topologies for PWR Switches
Installing the Switch
Sample Network Topologies for PWR
Switches
This section shows a few sample network topologies implementing the Series
2600-PWR Switches. For more topology information, see the ProCurve
networking products Web site, http://www.procurve.com.
As a Desktop Switch Implementing PoE
The Series 2600-PWR Switches are also designed to be used as desktop
switches to which end nodes, printers and other peripherals, and servers are
directly connected, as shown in the above illustration. Except now these
switches can supply PoE power to end devices such as IP telephones and
wireless access points (WAP).
As shown in the above illustration the IP telephones can be connected in line,
that is, between the switch and the end device, in this case a PC. The IP
telephones have two ports, one in and one out. Therefore the phone receives
voice and power from the switch and the PC can send and receive data through
the phone to the switch.
The end node devices are connected to the switch by straight-through or
crossover twisted-pair cables. Either cable type can be used because of the
“HP Auto-MDIX and “IEEE Auto MDI/MDI-X” features on the Series 2600-
PWR Switches.
Twisted-pair
straight-through
or crossover
cables
Server
2650-PWR
PCs and
peripherals
IP Telephones
Wireless Access
Point
600 RPS/EPS
2-37
Installing the Switch
Sample Network Topologies for PWR Switches
Installing the Switch
As a Segment Switch Implementing PoE
As shown in the illustration above, the IP telephones have been inserted in
between the Switch 2650-PWR and the PCs, and a WAP has been connected
to the Switch 2650-PWR. Both the telephones and WAP will receive PoE power
from the Switch 2650-PWR. Only devices directly connected to the PWR
switches can receive PoE power if they are 802.3af compliant, except on the
Switch 2600-8-PWR, it has the ability to supply power to pre-802.3af-standard
devices, such as legacy (or non-standard) IP phones. Devices connected to a
non-PWR segment switch cannot receive PoE power.
Po E
Po we r
Fault
Dual-Pers onality P or t:
10/1 00/1 000 -T (T) o r Mini-GBIC (M)
(Port 9T is IEEE A uto MDI/MDIX)
Status
Reset Clea r
Console
PoE-Integrated 10/100-TX P orts (1 - 8)
— (Portsare HP Aut o-MDIX)
ProCurve
Switch 2600-PWR
J8762A
*Spdmode : off= 10Mbps, flash= 100Mbps, on= 1000 Mbps
Link
Mode
LED
Mode
Spd
Act
FDx
Tes t
EPS
Fan
234
Link Mode
1
Link Mode
5 6 7 8 9T
Link Mode
PoE
*
9M
!
Useonly one (T or M) for P ort 9
RPS
Server with
Gigabit
Ethernet NIC
Switch 2650 Non-PWR
Category 5e twisted-pair straight-through or
crossover cable for 1000 Mbps connection to server
Gigabit
fiber-optic cable
uplink
Switch 2600-8-PWR
600 RPS/EPS
PCs, printers,
and local
servers
Wireless
Access Points
Switch
2650-PWR
Twisted-pair straight-
through or crossover cables
2-38
Installing the Switch
Sample Network Topologies for PWR Switches
Installing the Switch
Connecting to a Backbone Switch Implementing PoE
To Gigabit-Ethernet
backbone
Wireless
Access Point
600 RPS/EPS
Switch 2650-PWR
Switch 2650
Switch 2650-PWR
Gigabit
fiber-optic
cable
Switch 5308xl
Switch 2650 non-PWR
2-39
Installing the Switch
Sample Network Topologies for PWR Switches
Installing the Switch
Stacking the Switch
Switch 2600 and 2600-PWR Series devices can be connected together, through
standard network connections, and managed through a single IP address. Up
to 16 switches can be connected together in such a “virtual stack”.
You identify a Switch 2600 or 2600-PWR Series device as the “Commander”
and give that switch an IP address. Up to 15 other switches in the network can
then easily be configured as Members of the stack and managed through the
Commanders IP address. The management includes Telnet access and web
browser interface access to the Commander and to each Member switch
through the Commander.
For more information on stacking your switch, see the Management and
Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
— This page is intentionally unused. —
3-1
Configuring the Switch
3
Configuring the Switch
This chapter is a guide for using the console Switch Setup screen to quickly
assign an IP (Internet Protocol) address and subnet mask to the switch, set a
Manager password, and, optionally, configure other basic features.
For more information on using the switch console and the web browser
interface, please see the Management and Configuration Guide, which is on
the Documentation CD-ROM that came with your switch.
Recommended Minimal Configuration
In the factory default configuration, the switch has no IP (Internet Protocol)
address and subnet mask, and no passwords. In this state, it can be managed
only through a direct console connection. To manage the switch through in-
band (networked) access, you should configure the switch with an IP address
and subnet mask compatible with your network. Also, you should configure
a Manager password to control access privileges from the console and web
browser interface. Other parameters in the Switch Setup screen can be left at
their default settings or you can configure them with values you enter.
Many other features can be configured through the switch’s console interface,
to optimize the switch’s performance, to enhance your control of the network
traffic, and to improve network security. Once an IP address has been
configured on the switch, these features can be accessed more conveniently
through a remote Telnet session, through the switch’s web browser interface,
and from an SNMP network management station running a network
management program. For a listing of switch features available with and
without an IP address, refer to “How IP Addressing Affects Switch Operation”
in the Management and Configuration Guide, which is on the
Documentation CD-ROM that came with your switch.
For more information on IP addressing, refer to “IP Configuration” in the
Management and Configuration Guide.
3-2
Configuring the Switch
Configuring the Switch
N o t e By default, the switch is configured to acquire an IP address configuration
from a DHCP or Bootp server. To use DHCP/Bootp instead of the manual
method described in this chapter, see “DHCP/Bootp Operation” in the
Management and Configuration Guide, which is on the Documentation
CD-ROM that came with your switch.
Using the Console Setup Screen
The quickest and easiest way to minimally configure the switch for
management and password protection in your network is to use a direct
console connection to the switch, start a console session, and access the
Switch Setup screen.
1. Using the method described in the preceding section, connect a terminal
device to the switch and display the switch console command line
interface (CLI) prompt (the default display).
The CLI prompt appears, for example:
ProCurve#
2. At the prompt, enter the setup command to display the Switch Setup
screen. The following illustration shows the Setup screen with the default
settings.
3. Use the [Tab] key to select the Manager Password field and enter a manager
password of up to 16 printable ASCII characters.
2005
3-3
Configuring the Switch
Configuring the Switch
4. [Tab] to the IP Config (DHCP/Bootp) field and use the Space bar to select the
Manual option.
5. [Tab] to the IP Address field and enter the IP address that is compatible with
your network.
6. [Tab] to the Subnet Mask field and enter the subnet mask used for your
network.
7. Press [ Enter], then [S] (for Save).
Here is some information on the fields in the Setup screen. For more
information on these fields, see the Management and Configuration Guide,
which is on the Documentation CD-ROM that came with your switch:
Parameter Default
System Name blank Optional; up to 25 characters, including spaces
System Contact blank Optional; up to 48 characters, including spaces
Manager Password blank Recommended; up to 16 characters (no blank spaces)
Logon Default CLI The default setting selects the command line interface for console access.
The alternative is the menu interface.
Time Zone 0 (none) Optional; 1440 to -1440. The number of minutes your location is to the West (-)
or East (+) of GMT.
Community Name public Default setting recommended.
Spanning Tree Enabled No Default setting recommended unless STP is already running on your network
or the switch will be used in complex network topologies.
Default Gateway blank Optional; Enter the IP address of the next-hop gateway node if network traffic
needs to be able to reach off-subnet destinations.
Time Sync Method None Optional; The protocol the switch uses to acquire a time signal. The options
are SNTP and TimeP.
TimeP Mode Disabled Optional; The method the switch uses to acquire the TimeP server address.
IP Config (DHCP/Bootp) DHCP/Bootp Set to Manual unless a DHCP/Bootp server is used on your network to
configure IP addressing.
IP Address xxx.xxx.xxx.xxx Recommended; If you set IP Config to Manual, then enter an IP address
compatible with your network.
Note: The IP address and subnet mask assigned for the switch must be compatible with the IP addressing used in
your network. For more information on IP addressing, see the Management and Configuration Guide, which is on the
Documentation CD-ROM that came with your switch.
Subnet Mask xxx.xxx.xxx.xxx Recommended; If you entered an IP address, then enter a subnet mask
compatible with your network.
3-4
Configuring the Switch
Configuring the Switch
Where to Go From Here
The above procedure configures your switch with a Manager password, IP
address, and subnet mask. As a result, with the proper network connections,
you can now manage the switch from a PC equipped with Telnet, and/or a web
browser interface.
Some basic information on managing your switch is included in the next
section. For more information on the console, web browser, and SNMP
management interfaces and all the features that can be configured on the
Series 2600 Switches, see the Management and Configuration Guide, which
is on the Documentation CD-ROM that came with your switch.
To Recover from a Lost Manager Password: If you cannot start a
console session at the manager level because of a lost Manager password, you
can clear all passwords and user names by getting physical access to the
switch and pressing and holding the Clear button for a full second.
3-5
Configuring the Switch
Using the IP Address for Remote Switch Management
Configuring the Switch
Using the IP Address for Remote Switch
Management
With your switch, you can use the switch’s IP address to manage the switch
from any PC that is on the same subnet as the switch. You can use either a
Telnet session or a standard web browser to manage the switch.
Starting a Telnet Session
To access the switch through a Telnet session, follow these steps:
1. Make sure the switch is configured with an IP address and that the switch
is reachable from the PC that is running the Telnet session (for example,
by using a Ping command to the switch’s IP address).
2. Start the Telnet program on a PC that is on the same subnet as the switch
and connect to the switch’s IP address.
3. You will see the copyright page and the message “Press any key to
continue”. Press a key, and you will then see the switch console command
(CLI) prompt, for example:
ProCurve#
Enter help or ? to see a list of commands that can be executed at the
prompt. Entering any command followed by help provides more detailed
context help information about the command. Entering any command
followed by ? displays a list of options that are available at that point in
the command entry.
Starting a Web Browser Session
The Series 2600 Switches can be managed through a graphical interface that
you can access from any PC or workstation on the network by running your
web browser and typing in the switchs IP address as the URL. No additional
software installation is required to make this interface available; it is included
in the switch’s onboard software.
A typical web browser interface screen is shown in the next illustration.
3-6
Configuring the Switch
Using the IP Address for Remote Switch Management
Configuring the Switch
For more information on using the web browser interface, please see the
Management and Configuration Guide, which is on the Documentation
CD-ROM that came with your switch.
An extensive help system is also available for the web browser interface. To
access the help system though, the subnet on which the switch is installed
must have access to the internet.
4-1
Troubleshooting
4
Troubleshooting
This chapter describes how to troubleshoot your ProCurve Series 2600
Switch. This document describes troubleshooting mostly from a hardware
perspective. You can perform more in-depth troubleshooting on these devices
using the software tools available with the switches, including the full-
featured console interface, the built-in web browser interface, and ProCurve
Manager, the SNMP-based network management tool. For more information,
see the chapterTroubleshooting” in the Management and Configuration
Guide, which is on the Documentation CD-ROM that came with your switch.
This chapter describes the following:
basic troubleshooting tips (page 4-1)
diagnosing with the LEDs (page 4-4)
proactive networking tools (page 4-8)
hardware diagnostic tests (page 4-9)
restoring the factory default configuration (page 4-11)
downloading new software to the Series 2600 Switches (page 4-12)
HP Customer Support Services (page 4-12)
Basic Troubleshooting Tips
Most problems are caused by the following situations. Check for these items
first when starting your troubleshooting:
Connecting to devices that have a fixed full-duplex configuration.
The RJ-45 ports are configured as “Auto”. That is, when connecting to
attached devices, the switch operates in one of two ways to determine the
link speed and the communication mode (half duplex or full duplex):
If the connected device is also configured to Auto, the switch will
automatically negotiate both link speed and communication mode.
If the connected device has a fixed configuration, for example 100
Mbps,
at half or full duplex, the switch will automatically sense the
link speed, but will default to a communication mode of half duplex.
4-2
Troubleshooting
Basic Troubleshooting Tips
Troubleshooting
C a u t i o n Because the Series 2600 Switches behave in this way (in compliance with
the IEEE 802.3 standard), if a device connected to the switch has a fixed
configuration at full duplex, the device will not connect correctly to the
switch. The result will be high error rates and very inefficient communi-
cations between the switch and the device.
Ensure all devices connected to the Series 2600 Switches are configured
to auto negotiate, or are configured to connect at half duplex (all hubs are
configured this way, for example).
Faulty or loose cables. Look for loose or obviously faulty connections.
If the cables appear to be OK, make sure the connections are snug. If that
does not correct the problem, try a different cable.
Non-standard cables. Non-standard and miswired cables may cause
network collisions and other network problems, and can seriously impair
network performance. Use a new correctly-wired cable or compare your
cable to the cable in appendix B, “Switch Ports and Network Cables” for
pinouts and correct cable wiring. A category 5 cable tester is a
recommended tool for every 100Base-TX and 1000Base-T network
installation.
Improper Network Topologies. It is important to make sure you have
a valid network topology. Common topology faults include excessive
cable length and excessive repeater delays between end nodes. If you have
network problems after recent changes to the network, change back to
the previous topology. If you no longer experience the problems, the new
topology is probably at fault. Sample topologies are shown at the end of
chapter 2 in this book, and some topology configuration guidelines can
be found online at the ProCurve Web site, http://www.procurve.com.
In addition, you should make sure that your network topology contains
no data path loops. Between any two end nodes, there should be only
one active cabling path at any time. Data path loops will cause broadcast
storms that will severely impact your network performance.
For your Switch, if you wish to build redundant paths between important
nodes in your network to provide some fault tolerance, you should enable
Spanning Tree Protocol support on the switch. This ensures that only
one of the redundant paths is active at any time, thus avoiding data path
loops. Spanning Tree can be enabled through the switch console or the
web browser interface.
The Series 2600 Switches also support Trunking, which allows multiple
network cables to be used for a single network connection without
causing a data path loop. For more information on Spanning Tree and
Trunking, see the Management and Configuration Guide, which is on
the Documentation CD-ROM that came with your switch.
4-3
Troubleshooting
Basic Troubleshooting Tips
Troubleshooting
Check the port configuration. A port on your switch may not be
operating as you expect because it has been put into a “blocking” state by
Spanning Tree, GVRP (automatic VLANs), or LACP (automatic trunking).
(Note that the normal operation of the Spanning Tree, GVRP, and LACP
features may put the port in a blocking state.) Or, the port just may have
been configured as disabled through software.
Use the switch console to determine the port’s configuration and verify
that there is not an improper or undesired configuration of any of the
switch features that may be affecting the port. For more information, see
the Management and Configuration Guide, which is on the Documenta-
tion CD-ROM that came with your switch.
For more information on possible network problems and their solutions, refer
to the technical note “Troubleshooting LAN Performance and Intermittent
Connectivity Problems”, which can be found on the ProCurve Web site,
http://www.procurve.com, in the Reference Library section, A-Z Index.
4-4
Troubleshooting
Diagnosing with the LEDs
Troubleshooting
Diagnosing with the LEDs
Table 4-1 shows LED patterns on the switch and the switch modules that
indicate problem conditions.
1. Check in the table for the LED pattern you see on your switch.
2. Refer to the corresponding diagnostic tip on the next few pages.
Table 4-1. LED Error Indicators
LED Pattern Indicating Problems
Diagnostic
Tips
Power Fault RPS EPS Self Test Fan
Status Port LED
(in Link view mode)
Off with
power cord
plugged in
1 1 1 1 1 1
On Prolonged On 1 1 Prolonged On 1 1
On Blinking
21 1 Blinking
21 1
On Blinking
21 1 Off Blinking
21
On Blinking
21 1 Blinking
21Blinking
2
On Off 1 1 Off 1Off with cable
connected
On Off 1 1 Off 1On, but the port is not
communicating
On Blinking Blinking Blinking 1 1
1This LED is not important for the diagnosis.
2The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
4-5
Troubleshooting
Diagnosing with the LEDs
Troubleshooting
Diagnostic Tips:
Tip Problem Solution
The switch is not
plugged into an
active AC power
source, or the
switch’s power
supply may have
failed.
1. Verify the power cord is plugged into an active power source and to the switch. Make
sure these connections are snug.
2. Try power cycling the switch by unplugging and plugging the power cord back in.
3. If the Power LED is still not on, verify the AC power source works by plugging another
device into the outlet. Or try plugging the switch into a different outlet or try a different
power cord.
If the power source and power cord are OK and this condition persists, the switch power
supply may have failed. Call your HP-authorized LAN dealer, or use the electronic support
services from HP to get assistance. See the Customer Support/Warranty booklet for more
information.
A switch
hardware failure
has occurred. All
the LEDs will stay
on indefinitely.
Try power cycling the switch. If the fault indication reoccurs, the switch may have failed.
Call your HP-authorized LAN dealer, or use the electronic support services from HP to get
assistance. See the Customer Support/Warranty booklet for more information.
The switch has
experienced a
software failure
during self test.
1. Try resetting the switch by pressing the Reset button on the front of the switch, or by
power cycling the switch.
2. If the fault indication reoccurs, attach a console to the switch (as indicated in chapter
2) and configure it to operate at 9600 baud. Then, reset the switch. Messages should
appear on the console screen and in the console log identifying the error condition.
You can view the console log at that point by selecting it from the console Main Menu.
If necessary to resolve the problem, contact your HP-authorized LAN dealer, or use the
electronic support services from HP to get assistance. See the Customer Support/
Warranty booklet for more information.
One or both of the
switch cooling
fans may have
failed.
Try disconnecting power from the switch and wait a few moments. Then reconnect the
power to the switch and check the LEDs again. If the error indication reoccurs, one or
both of the fans has failed. The switch has two fans and may continue to operate under
this condition if the ambient temperature does not exceed normal room temperature, but
for best operation, the switch should be replaced. Contact your HP-authorized LAN dealer,
or use the electronic support services from HP to get assistance. See the Customer
Support/Warranty booklet for more information.
The network port
for which the LED
is blinking has
experienced a
self test or
initialization
failure.
Try power cycling the switch. If the fault indication reoccurs, the switch port may have
failed. Call your HP-authorized LAN dealer, or use the electronic support services from
HP to get assistance. See the Customer Support/Warranty booklet for more information.
If the port is a mini-GBIC, verify that it is one of the mini-GBICs supported by the switch.
Unsupported mini-GBICs will be identified with this fault condition. The supported
mini-GBICs are listed in Chapter 2, “Installing the Switch” on page 2-7. The
mini-GBICs are also tested when they are “hot-swapped”—installed or changed while
the switch is powered on.
To verify that the port has failed, try removing and reinstalling the mini-GBIC without
having to power off the switch. If the port fault indication reoccurs, you will have to
replace the mini-GBIC.
continued on the next page
4-6
Troubleshooting
Diagnosing with the LEDs
Troubleshooting
The network
connection is not
working
properly.
Try the following procedures:
For the indicated port, verify that both ends of the cabling, at the switch and the
connected device, are connected properly.
Verify the connected device and switch are both powered on and operating correctly.
Verify you have used the correct cable type for the connection:
For twisted-pair connections to the fixed 10/100 or 10/100/1000 ports, if the port is
configured toAuto” (auto negotiate), either straight-through or crossover cables
can be used because of the switchs “HP Auto-MDIX” feature and the Auto MDI/
MDI-X feature of the 10/100/1000-T port.
Note: If the switch port configuration is changed to one of the fixed configuration
options (for example, 100 Mbps/Full Duplex), then the port operates as MDI-X only
and you must use the correct type of cable for the connection. In general, for
connecting an end node (MDI port) to the switch, use straight-through cable; for
connecting to MDI-X ports on hubs, other switches, and routers, use crossover
cable.
For fiber-optic connections, verify the transmit port on the switch is connected to
the receive port on the connected device, and the switch receive port is connected
to the transmit port on the connected device.
For the dual-personality 10/100/1000-T ports, be sure a mini-GBIC is not installed in the
associated slot.
For 1000Base-T connections, verify the network cabling complies with the IEEE 802.3ab
standard. the cable should be installed according to the ANSI/TIA/EIA-568-A-5
specifications. Cable testing should comply with the stated limitations for Attenuation,
Near-End Crosstalk, Far-End Crosstalk, Equal-Level Far-End Crosstalk (ELFEXT),
Multiple Disturber ELFEXT, and Return Loss.
The cable verification process must include all patch cables from any end devices,
including the switch, to any patch panels in the cabling path.
Verify the port has not been disabled through a switch configuration change. You can
use the console interface, or, if you have configured an IP address on the switch, use
the web browser interface to determine the state of the port and re-enable the port if
necessary.
Verify the switch port configuration matches the configuration of the attached device.
For example, if the switch port is configured as “Auto”, the port on the attached device
also MUST be configured as “Auto”. Depending on the port type, twisted-pair or fiber-
optic, if the configurations don’t match, the results could be a very unreliable
connection, or no link at all.
If the other procedures don’t resolve the problem, try using a different port or a different
cable.
Tip Problem Solution
4-7
Troubleshooting
Diagnosing with the LEDs
Troubleshooting
The port may be
improperly
configured, or
the port may be in
a “blocking”
state by the
normal operation
of the Spanning
Tree, LACP, or
IGMP features.
Use the switch console to see if the port is part of a dynamic trunk (through the LACP
feature) or to see if Spanning Tree is enabled on the switch, and to see if the port may
have been put into a “blocking” state by those features. The show lacp command displays
the port status for the LACP feature; the show spanning-tree command displays the port
status for Spanning Tree.
Also check the Port Status screen using the show interfaces command to see if the port
has been configured as “disabled”.
Other switch features that may affect the port operation include VLANs and IGMP. Use
the switch console to see how the port is configured for these features.
For software troubleshooting tips, see the chapter “Troubleshootingin the Management
and Configuration Guide, which is on the Documentation CD-ROM that came with your
switch.
Ensure also, that the device at the other end of the connection is indicating a good link
to the switch. If it is not, the problem may be with the cabling between the devices or the
connectors on the cable.
RPS or EPS is
connected but
has experienced
a fault.
Refer to the ProCurve 600/610 External Power Supplies documentation.
Tip Problem Solution
4-8
Troubleshooting
Proactive Networking
Troubleshooting
Proactive Networking
The ProCurve Series 2600 Switches have built-in management capabilities that
proactively help you manage your network including:
finding and helping you fix the most common network error conditions
(for example, faulty network cabling, and non-standard network
topologies)
informing you of the problem with clear, easy-to-understand messages
recommending network configuration changes to enhance the
performance of your network
The following interfaces provide tests, indicators, and an event log that can
be used to monitor the switch and its network connections and to help you
take advantage of these proactive networking features:
A graphical web browser interface you can use to manage your switch
from a PC running a supported web browser, for example Microsoft
Internet Explorer, and Netscape Communicator.
A full-featured easy-to-use console interface you can access by connecting
a standard terminal or PC running a terminal emulator to the switchs
console port. The cable to make that connection is provided with your
switch. The console interface is also accessible through a Telnet
connection.
For more information on using these software tools to diagnose and manage
your switch, see the “Troubleshooting” chapter in the Management and
Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
4-9
Troubleshooting
Hardware Diagnostic Tests
Troubleshooting
Hardware Diagnostic Tests
Testing the Switch by Resetting It
If you believe the switch is not operating correctly, you can reset the switch
to test its circuitry and operating code. To reset a switch, either:
unplug and plug in the power cord (power cycling)
press the Reset button on the front of the switch
Power cycling the switch and pressing the Reset button both cause the switch
to perform its power-on self test, which almost always will resolve any
temporary operational problems. These reset processes also cause any
network traffic counters to be reset to zero, and cause the System Up Time
timer to reset to zero.
Checking the Switch LEDs
The self test passes if the Fault and Self Test LEDs on the front of the switch
go off after approximately 50 seconds. If these LEDs stay on longer than 60
seconds or begin blinking, there may be a problem with the switch.
See “Diagnosing With the LEDs” on page 4-4 for information on interpreting
the LED patterns.
Checking Console Messages
Useful diagnostic messages may be displayed on the console screen when the
switch is reset. As described in chapter 2 under step 7, Connect a Console to
the Switch connect a PC running a VT-100 terminal emulator program or a
standard VT-100 terminal to the switch’s Console Port and configure it to run
at 9600 baud, and with the other terminal communication settings shown on
“Configuring the Switch. Then, when you reset the switch, note the messages
that are displayed. Additionally, you can check the switch event log, which
can be accessed from the console using the show log command, or from the
console Main Menu after entering the Menu command.
4-10
Troubleshooting
Hardware Diagnostic Tests
Troubleshooting
Testing Twisted-Pair Cabling
Network cables that fail to provide a link or provide an unreliable link between
the switch and the connected network device may not be compatible with the
IEEE 802.3 Type 10Base-T, 100Base-TX, or 1000Base-T standards. The twisted-
pair cables attached to the switch must be compatible with the appropriate
standards. To verify your cable is compatible with these standards, use a
qualified cable test device.
Testing Switch-to-Device Network Communications
You can perform the following communication tests to verify the network is
operating correctly between the switch and any connected device that can
respond correctly to the communication test.
Link Test—a physical layer test that sends IEEE 802.2 test packets to any
device identified by its MAC address
Ping Test—a network layer test used on IP networks that sends test
packets to any device identified by its IP address
These tests can be performed through the switch console interface from a
terminal connected to the switch or through a Telnet connection, or from the
switch’s web browser interface. For more information, see the Management
and Configuration Guide, which is on the Documentation CD-ROM that came
with your switch.
Testing End-to-End Network Communications
Both the switch and the cabling can be tested by running an end-to-end
communications test—a test that sends known data from one network device
to another through the switch. For example, if you have two PCs on the
network that have LAN adapters between which you can run a link-level test
or Ping test through the switch, you can use this test to verify that the entire
communication path between the two PCs is functioning correctly. See your
LAN adapter documentation for more information on running a link test or
Ping test.
4-11
Troubleshooting
Restoring the Factory Default Configuration
Troubleshooting
Restoring the Factory Default
Configuration
As part of your troubleshooting process on the Switch, it may become
necessary to return the switch configuration to the factory default settings.
This clears any passwords, clears the console event log, resets the network
counters to zero, performs a complete self test, and reboots the switch into
its factory default configuration including deleting the IP address, if one is
configured.
N o t e This process removes all switch configuration changes that you have made
from the factory default settings. This includes, for example, configuration of
VLANs, Spanning Tree, trunks, and stacking. Returning the configuration of
these features to their factory default settings (usually disabling them) may
result in network connectivity issues.
If the switch has a valid configuration, and you are restoring the factory default
settings for a reason other than configuration problems, you should save the
switch configuration prior to performing the factory default reset. Then, after
the reset and resolution of the original problem, you can restore the saved
configuration to the switch. For both the save and restore processes, you can
use the console copy command. For more information on this command, see
the Management and Configuration Guide, which is on the Documentation
CD-ROM that came with your switch.
You can restore the factory default configuration either on the switch itself,
or through the switch console.
To execute the factory default reset on the switch, perform these steps:
1. Using pointed objects, simultaneously press both the Reset and Clear
buttons on the front of the switch. The power and fault lights come on.
2. Continue to press the Clear button while releasing the Reset button.
3. When the Self Test LED begins to blink, release the Clear button.
The switch will then complete its self test and begin operating with its
configuration restored to the factory default settings.
To restore the factory default configuration using the console, execute the
erase startup-config command from the console command prompt.
4-12
Troubleshooting
Downloading New Switch Software
Troubleshooting
Downloading New Switch Software
When product enhancements occur for the Series 2600 Switches, new
software can be downloaded to the switch through several methods, for
product enhancements and new features. For more information, see the
Management and Configuration Guide, which is on the Documentation CD-
ROM that came with your switch.
The new switch software would be available on the ProCurve Web site,
http://www.procurve.com.
HP Customer Support Services
If you are still having trouble with your switch, Hewlett-Packard offers support
24 hours a day, seven days a week through the use of a number of automated
electronic services. See the Customer Support/Warranty booklet that came
with your switch for information on how to use these services to get technical
support. The ProCurve Web site, http://www.procurve.com also provides up-
to-date support information.
Additionally, your HP-authorized network reseller can provide you with
assistance, both with services that they offer and with services offered by HP.
Before Calling Support
Before calling your networking dealer or HP Support, to make the support
process most efficient, you first should retrieve the following information:
Information Item Information Location
product identification, including mini-GBICs the front of the switch and on
labels on the mini-GBICs
details about the switch’s status including the
software (OS) version, a copy of the switch
configuration, a copy of the switch Event Log, and a
copy of the switch status and counters information
switch console: show tech
command
copy of your network topology map, including
network addresses assigned to the relevant devices
your network records
A-1
Switch Specifications
A
Switch Specifications
Physical
Electrical
The switch automatically adjusts to any voltage between 100-240 volts and
either 50 or 60 Hz.
2600 Non-PWR Series Width Depth Height Weight
2626 (J4900B) 44.3 cm (17.4 in) 36.7 cm (14.4 in) 4.4 cm (1.73 in) 4.62 kg (10.20 lbs)
2650 (J4899B) 44.3 cm (17.4 in) 43.0 cm (16.9 in) 4.4 cm (1.73 in) 4.88 kg (10.75 lbs)
2600-PWR Series
2600-8-PWR (J8762A) 44.3 cm (17.4 in) 22.5 cm (8.86 in) 4.4 cm (1.73 in) 3.4 kg (7.5 lbs)
2626-PWR (J8164A) 44.3 cm (17.4 in) 48.3 cm (19.0 in) 4.4 cm (1.73 in) 6.84 kg (15.05 lbs)
2650-PWR (J8165A) 44.3 cm (17.4 in) 48.3 cm (19.0 in) 4.4 cm (1.73 in) 7.58 kg (16.70 lbs)
2600 Non-PWR Series AC voltage Maximum current Frequency range
2626 (J4900B) 100-240 volts 1.5A 50/60 Hz
2650 (J4899B) 100-240 volts 1.5A 50/60 Hz
2600-PWR Series
2600-8-PWR (J8762A) 100-240 volts 3.3A-1.7A 50/60 Hz
2626-PWR (J8164A) 100-240 volts 7.5A-3.5A 50/60 Hz
2650-PWR (J8165A) 100-240 volts 7.5A-3.5A 50/60 Hz
A-2
Switch Specifications
Switch Specifications
Environmental
BTU Ratings
Acoustic
Non-PWR 2600 Series (J4899B/J4900B)
Geraeuschemission LwA=50 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=50 dB at virtual work space according to DIN 45635 T.19
2600-PWR switches (J8164A/J8165A)
Geraeuschemission LwA=53 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=53 dB at virtual work space according to DIN 45635 T.19
2600-8-PWR switch (J8762A)
Geraeuschemission LwA=55 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=55 dB at virtual work space according to DIN 45635 T.19
Non-PWR 2600 Series Operating Non-Operating
Temperature 0 F)°C to 55 °C (32 °F to 131 °F) -40 °C to 70 °C (-40 °F to 158 °
Relative humidity
(non-condensing)
15% to 95% at 40 °C (104 °F) 15% to 90% at 65 °C (149 °F)
Maximum altitude 4.6 Km (15,000 ft) 4.6 Km (15,000 ft)
2600-PWR Series Operating Non-Operating
Temperature 0 F)°C to 50 °C (32 °F to 122 °F) -40 °C to 70 °C (-40 °F to 158 °
Relative humidity
(non-condensing)
15% to 95% at 40 °C (104 °F) 15% to 90% at 65 °C (149 °F)
Switch Model Combined BTU 1Switch only BTU
2600-8-PWR 649 228
2626-PWR 2288 921
2650-PWR 2288 921
2626 Non-PoE 341
2650 Non-PoE 341
1 Includes switch and maximum number of PoE powered devices
connected to the switch at 15.4 watts.
A-3
Switch Specifications
Switch Specifications
Connectors
The 10/100/1000 Mbps RJ-45 twisted-pair ports are compatible with the
following standards:
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3 10Base-T
The 1000 Mbps LC fiber-optic ports on the Gigabit-SX and Gigabit-LX mini-
GBIC transceivers are compatible with the IEEE 802.3z Gigabit-SX and
Gigabit-LX standards.
EPS connector: A 2x7 Molex Micro-Fit connector should be used for EPS
connection.
RPS connector: A 2x7 connector is provided for external RPS connection
on the power supply module.
Cable Length
EPS cables are 2.0 meters (6.56 feet) in length
RPS cables are 1.25 meters (4.10 feet) in length
Safety
Complies with:
EN60950 / IEC 6095
CSA 22.2 No. 950
UL 60950
Lasers
The Gigabit-SX LC mini-GBIC, and the Gigabit-LX LC mini-GBIC, both of
which can be installed in the Series 2600 Switches, are Class 1 Laser Products.
Laser Klasse 1
These mini-GBICs comply with IEC 60825.


Produkt Specifikationer

Mærke: HP
Kategori: Ikke kategoriseret
Model: ProCurve 2600

Har du brug for hjælp?

Hvis du har brug for hjælp til HP ProCurve 2600 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret HP Manualer

HP

HP Engage Flex Pro G2 Manual

27 December 2024
HP

HP Voyager Legend 50 Manual

27 December 2024
HP

HP L3H30AAE Manual

30 September 2024
HP

HP Elite mt645 G8 Manual

6 September 2024
HP

HP Jetdirect 640n Manual

4 September 2024
HP

HP gt7720 Manual

3 September 2024
HP

HP t5545 Manual

3 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer