Mounting Instructions
Flush mountable tubular switches / CSA Div. 2
Flush mountable switches can be mounted so that the ac-
tive face is flush with a metal surface. Any metal in front
of the switch should be kept at a distance of three times
the nominal sensing range.
s = nominal sensing range
b = maximum thread length
M8 - 8 mm, M12 - 8 mm
M18 - 8 mm, M30 - 16 mm
3xs
b
Two flat nuts are provided to hold the installed switch in
place.
When mounting tubular switches opposite each other, the spacing distance
shown here should be maintained.
Sr = nominal sensing range
8 x Sr
active face
When mounting tubular switches next to each other, the spacing distance
shown here should be maintained.
D = switch diameter
D
DD
active face
active face
CSA for Hazardous Locations
When wired in accordance with CEC and this mounting instructions.
Class I, Div. 2, Groups A, B, C and D
Class II, Div. 2, Groups E, F and G
Class III, T4
Enclosure: Type 4/4x
Temp. range: -13° to 176°F (-25° to 80°C)
ELECTRICAL
DO NOT operate an incandescent light bulb as a load.
The current inrush when the bulb is cold can cause a
current overload.
DO NOT operate a proximity sensor directly from a
voltage supply without a load. This is a short circuit and
can cause damage. Note: insert a miniature fuse accor-
ding to the technical data sheet, if specified.
Concerning Safety... ifm efector makes every effort to build a de-
pendable product, but every product will eventually fail. Therefore,
your equipment must be designed to prevent property damage
and personal injury if our products fail. ifm efector proximity
switches are not designed to be used as stand-alone devices to
protect or guard human life or limb.
WARNING
Explosion Hazard – substitution of components may impair suitability
of Class 1, Div. 2. Do not disconnect while circuit is live unless area is
known to be non-hazardous.
AVERTISSEMENT
Risque d'explosion - La Substitution de composants peut rendre ce
matérielle inacceptable pour les emplacements de classe I division 2.
Ne pas débrancher tant que le circuit est sous tensions, à moins qu'il
ne s'agisse d'un emplacement non dangereux.
CAUTION
Use only ifm efector conduit adapters (U30029, U30030, U30031) or
other CSA ceritifed conduit adapters.
ATTENTION
Utiliser uniquement les adaptateurs tube d'ifm efector (U30029,
U30030, U30031) ou d'autres adaptateurs tube certifiés par CSA.


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: IG5783

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM IG5783 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM IIS719 Manual

15 November 2024
IFM

IFM E2M232 Manual

15 November 2024
IFM

IFM CR1144 Manual

9 November 2024
IFM

IFM CR1143 Manual

9 November 2024
IFM

IFM AC434S Manual

8 November 2024
IFM

IFM LW2760 Manual

2 November 2024
IFM

IFM AC901S Manual

15 Oktober 2024
IFM

IFM PT5503 Manual

14 Oktober 2024
IFM

IFM TD2911 Manual

14 Oktober 2024
IFM

IFM MK5186 Manual

13 Oktober 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024