Mounting Instructions
Inductive nonflush mountable rectangular switches / CSA Div. 2
Nonflush mountable rectangular switches should have a metal-free zone surrounding the sensing face in accordance with the diagrams
shown here.
Metal
B
Sensing Face
1.5xB
B = width of sensing face
Sn = nominal sensing range
Metal
B
3xSn
2xB
Sensing Face
Non-target
background metal
2xB
B = width of sensing face
Sn = nominal sensing range
B2xB
Sensing Face
B
Metal B = width of sensing face
8xSn
Sensing Face
Sn = nominal sensing range
CSA for Hazardous Locations
When wired in accordance with CEC and this mounting instructions.
Class I, Div. 2, Groups A, B, C and D
Class II, Div. 2, Groups E, F and G
Class III, T4
Enclosure: Type 4/4x
Temp. range: -13° to 176°F (-25° to 80°C)
ELECTRICAL
DO NOT operate an incandescent light bulb as a load.
The current inrush when the bulb is cold can cause a
current overload.
DO NOT operate a proximity sensor directly from a vol-
tage supply without a load. This is a short circuit and can
cause damage. Note: insert a miniature fuse according to
the technical data sheet, if specified.
Concerning Safety... ifm efector makes every effort to build a de-
pendable product, but every product will eventually fail. Therefore,
your equipment must be designed to prevent property damage and
personal injury if our products fail. ifm efector proximity switches
are not designed to be used as stand-alone devices to protect or
guard human life or limb.
WARNING
Explosion Hazard – substitution of components may impair suitabi-
lity of Class 1, Div. 2. Do not disconnect while circuit is live unless
area is known to be non-hazardous.
AVERTISSEMENT
Risque d'explosion - La Substitution de composants peut rendre ce
matérielle inacceptable pour les emplacements de classe I division
2. Ne pas débrancher tant que le circuit est sous tensions, à moins
qu'il ne s'agisse d'un emplacement non dangereux.
CAUTION
Use only ifm efector conduit adapters (U30029, U30030, U30031) or
other CSA ceritifed conduit adapters.
ATTENTION
Utiliser uniquement les adaptateurs tube d'ifm efector (U30029,
U30030, U30031) ou d'autres adaptateurs tube certifiés par CSA.


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: IN0098

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM IN0098 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM OVP812 Manual

25 Januar 2025
IFM

IFM AE3400 Manual

25 Januar 2025
IFM

IFM DTE932 Manual

25 Januar 2025
IFM

IFM DTE931 Manual

25 Januar 2025
IFM

IFM DTE934 Manual

25 Januar 2025
IFM

IFM EVF729 Manual

25 Januar 2025
IFM

IFM EVT728 Manual

25 Januar 2025
IFM

IFM ID5058 Manual

25 Januar 2025
IFM

IFM KB0025 Manual

25 Januar 2025
IFM

IFM PN2043 Manual

25 Januar 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer