Installation instructions
Inclination sensor JD
80294704/00 05/2020
1 Preliminary note
You will find the device manual, technical data, approvals, accessories and further
information at www.ifm.com.
2 Safety instructions
The device described is a subcomponent for integration into a system.
- The manufacturer is responsible for the safety of the system.
- The system manufacturer undertakes to perform a risk assessment and to
create a documentation in accordance with legal and normative requirements
to be provided to the operator and user of the system. This documentation
must contain all necessary information and safety instructions for the operator,
the user and, if applicable, for any service personnel authorised by the
manufacturer of the system.
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
Only use the product for its intended purpose (→ 3 Function and features).
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, programming, configuration, operation
and maintenance of the product must be carried out by personnel qualified and
authorised for the respective activity.
Protect units and cables against damage.
3 Functions and features
Dynamic MEMS inclinometers sense and measure the angle of tilt (inclination/
slope/elevation) of an object.
JD1xxx: 1-axis sensor with angular range 0...360° (vertical installation).
JD2xxx: 2-axis sensor with angular range ±90° (horizontal installation).
4 Installation
Choose a level mounting surface.
Fix the unit using 4 screws, tightening torque 1.5...2.5 Nm.
Recommendation:
M6 screws or ¼” UNC screws
Adjust M12 connectors precisely and screw them fully into the unit, tightening
torque 1.5 Nm.
5 Electrical connection
The inclinometer is connected via a 5-pin M12 connector.
Pin configuration
4
2 1
3
5
1: CAN _GND
2: Supply voltage 24 V DC (+U
B
)
3: GND
4: CAN_H High bus cable
5: CAN_L Low bus cable
M12 connector CAN-In
3
1 2
4
5
1: CAN _GND
2: Supply voltage 24 V DC (+U
B
)
3: GND
4: CAN_H High bus cable
5: CAN_L Low bus cable
M12 socket CAN-Out
5.1 Bus termination
The sensor has a terminating resistor that can be enabled (120 Ω). Depending on
the interface, this resistor can be activated via the software (default: deactivated).


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: JD1121

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM JD1121 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM IIS719 Manual

15 November 2024
IFM

IFM E2M232 Manual

15 November 2024
IFM

IFM CR1144 Manual

9 November 2024
IFM

IFM CR1143 Manual

9 November 2024
IFM

IFM AC434S Manual

8 November 2024
IFM

IFM LW2760 Manual

2 November 2024
IFM

IFM AC901S Manual

15 Oktober 2024
IFM

IFM PT5503 Manual

14 Oktober 2024
IFM

IFM TD2911 Manual

14 Oktober 2024
IFM

IFM MK5186 Manual

13 Oktober 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024