U ser In str u c tio n s, In sta l lati on, ma inte n ance for
• C O O K E R S •
Cookers characteristics
These warnings refer to different models of cookers.
Be sure that you have correctly identified the model that you possess (see the data plate).
MODEL DIMENSIONS
UP60 23 5/8 (W) x 23 5/8 (D) x [33 15/32- 35 53/64] (H)
UP70 27 9/16 (W) x 23 5/8 (D) x [33 15/32- 35 53/64] (H)
UM70 27 9/16 (W) x 27 9/16 (D) x [34 1/4- 36 20/32] (H)
UP76 29 7/8 (W) x 23 5/8 (D) x [33 15/32 - 35 53/64] (H)
UM76 29 7/8 (W) x 27 9/16 (D) x [34 1/4- 36 20/32] (H)
UP90, UPD90, UQDC90 35 7/16 (W) x 23 5/8 (D) x [33 15/32- 35 53/64] (H)
UM90 35 7/8 (W) x 27 9/16 (D) x [34 1/4- 36 20/32] (H)
UPD100, UQDC100 39 3/8 (W) x 23 5/8 (D) x [33 15/32- 35 53/64] (H)
UMD100 39 3/8 (W) x 27 9/16 (D) x [34 1/4- 36 20/32] (H)
UP120, UPD120 47 1/4 (W) x 23 5/8 (D) x [33 15/32- 35 53/64] (H
UM120, UMS120 47 7/8 (W) x 27 9/16 (D) x [34 1/4- 36 20/32] (H)
UP150 59 1/16 (W) x 23 5/8 (D) x [33 15/32- 35 53/64] (H)
UM150 59 1/2 (W) x 27 9/16 (D) x [34 1/4- 36 20/32] (H)
M
M
M
Ma
a
a
aj
j
j
je
e
e
es
s
s
st
t
t
ti
i
i
ic
c
c
c
P
P
P
Pr
r
r
ro
o
o
of
f
f
fe
e
e
es
s
s
ss
s
s
si
i
i
io
o
o
on
n
n
na
a
a
al
l
l
l
Q
Q
Q
Qu
u
u
ua
a
a
ad
d
d
dr
r
r
ra
a
a
aMaje stic Pro fessio nal Qua dr a
cod. I/301/89
2
Installation must conform with local codes or in absence of codes, the National Fuel Gas Code ANSIZ223.1-latest
edition. Electrical installation must be in accordance with the National Electrical Code, ANIS/NFPA70 latest
edition and/or local codes. IN CANADA: Installation must be in accordance with the current CAN/CGA-B149.1
National Gas
Installation Code or CAN/CGA-B 149.2, Propane. Installation Code and/or local codes. Electrical installation must
be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
Installation of any gas red equipment should be made by a licensed plumber. A manual gas shut-off valve must
be installed in the gas supply line ahead of the oven in the gas stream for safety and ease of service.
In Massachusetts: All gas products must be installed by a “Massachusetts” licensed plumber or gas tter. A “T”
handle type manual gas valve must be installed in the gas supply line to this appliance.
The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation
or improper use of the appliance.
The manufactured reserves the right to make changes to its products when considered necessary and useful,
without affecting the essential safety and operating characteristics.
This appliance has been designed for non-professional, domestic use only.
This appliance must be used only for the purposes for which it was intended. Any other use is incorrect and
therefore dangerous.
Possible hazards or injuries which may result from the misuse of appliance doors or drawers such as stepping,
leaning or sitting on the doors or drawers.
Possible hazards may result from using this appliance for storage space.
I M P O R TA N T - P L E A S E R E A D A N D F O L L O W
Before beginning, please read these instructions
completely and carefully.
Do not remove permanently af xed labels, warnings, or
plates from the product. This may void the warranty.
Please observe all local and national codes and
ordinances.
Please ensure that this product is properly grounded.
The installer should leave these instructions with the
consumer who should retain for local inspector’s use and
for future reference.
NEVER use this appliance as a space heater to heat
or warm the room. Doing so may result in carbon
monoxide poisoning and overheating of the oven.
WARNING
3
Keeping appliance area clear and free from combustible materials, gasoline and other ammable vapors
and liquids.
I M P O R T A N T I N S T R U C T I O N
All Appliances:
Do Not Leave Children Alone - Children should not be left alone or unattended in area where appliance is in use.
They should never be allowed to sit or stand on any part of the appliance.
Wear Proper Apparel - Loose- tting or hanging garmets should never be worn while using the appliance.
User Servicing - Do not repair or replace any part of the appliance unless speci cally recommended in the manual.
All other servicing should be referred to a quali ed technician.
Storage in or on Appliance - Flammable materials should not be stored in an oven or near surface units.
Do Not Use Water on Grease Fires - Smother re or ame or use dry chemical or foam type extinguisher.
Use Only Dry Potholders - Moist or damp potholders on hot surfaces may resultin burns from steam. Do not let
potholder touch hot heating elements. Do not use a towel or other bulky cloth.
Ovens:
Use Care When Opening Door - Let hot air or steam escape before removing or replacing food.
Do Not Heat Unopened Food Containers - Build-up of pressure may cause container to burst and result injury.
Keep Oven Vent Duct Unobstructed.
Placement of Oven Racks - Always place oven racks in desired location while oven is cool. If rack must be moved
while oven is hot, do not let potholder contact hot heating element in oven.
CAUTION
Do not store items of interest to children in cabinets above a range or on the backguard of a range - children climbing on the range to
reach items can be seriously injured.
DO NOT TOUCH HEATING ELEMENTS OR INTERIOR SURFACES OF OVEN
Heating elements may be hot even though they are dark in color. Interior surfaces of an oven become hot enough to cause burns. During
and after use, do not touch, or let clothing or other fl ammable materials contact heating elements or interior surfaces of oven until they
have had suffi cient time to cool. Other surfaces of the appliance may become hot enough to cause burns - among these surfaces are
(identifi cation of surfaces - for example, oven vent openings and surfaces near these opening, oven doors, and windows of the oven
door).
4
I N S T A L L AT I O N I N S T R U C T I O N S
This appliance shall only be installed by an authorized person. This appliance shall be installed in
accordance with the manufactures installation instructions, IMPORTANT: this appliance must be installed in
accordance with the norms in force of the country concerned.
The installation of this appliance must conform to local codes and ordinances. In the absence of local codes.
Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1-54
If local codes permit, a exible metal appliance connection with the new AGA or CGA certi ed design,
max. 5 feet (1,5m) long, ½” I.D. recommended for connecting this cooktop to the gas supply line. Do not
bend or damage the exible connector when moving the cooktop. The pressure regulator has ½” female
pipe thread. You will need to determine the tting required, depending on the size of your gas supply line,
the exible metal connector and the shutoff valve.
The appliance , when installed, must be electrically grounded in accordance with local codes or, in absence
of local codes, with the National Electrical Code, ANSI/NFPA 70.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system
any pressure testing of that system at test pressure in excess of ½psi (3,5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressure equal to or less than
½psi (3,5kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance; it shall be
properly installed in order to be accessible when appliance is installed in de nitive position.
The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural gas and LP Gas. It is shipped from the factory adjusted for use
with Natural gas: CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK SUPPLIED
WITH THE UNIT.
Injectors kit for the change of type of gas are contained inside the package jointly with the hob installation
kit and Instruction booklet. The maximum inlet gas supply pressure incoming to the gas appliance pressure
regulator is 20” water column (5kPa). The minimum gas supply pressure for checking the regulator setting
shall be at least 1”w.c.(249Pa) above the inlet speci ed manifold pressure to the appliance (this operating
pressure is 5”w.c. for Natural Gas and 10”w.c. for LP Gas.All opening and holes in the wall and oor, back
and under the appliance shall be sealed before installation of the appliance.
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance for the
purpose of turning on or shutting off gas to the appliance.
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation.
The appliances should not be installed with a ventilation system that blows air downward toward the range.


Produkt Specifikationer

Mærke: Ilve
Kategori: Komfur
Model: UP76

Har du brug for hjælp?

Hvis du har brug for hjælp til Ilve UP76 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Komfur Ilve Manualer

Ilve

Ilve H360 Manual

4 Maj 2024
Ilve

Ilve H30 Manual

29 April 2024
Ilve

Ilve HPT95FD Manual

9 April 2024
Ilve

Ilve INB74B Manual

14 Marts 2024
Ilve

Ilve UP60 Manual

8 Marts 2024
Ilve

Ilve H60 Manual

1 Marts 2024
Ilve

Ilve P965 Manual

8 Februar 2024
Ilve

Ilve KHVI60TC Manual

30 Januar 2024
Ilve

Ilve UQDC100 Manual

10 November 2023
Ilve

Ilve MDC-120 Manual

7 November 2023

Komfur Manualer

Nyeste Komfur Manualer

EWT

EWT Jazz Manual

5 Januar 2025
EWT

EWT PF320LCD Manual

5 Januar 2025
Café

Café CEP90302TSS Manual

4 Januar 2025
MSW

MSW -CCT-06 Manual

4 Januar 2025
MSW

MSW -CCT-08 Manual

4 Januar 2025
Caple

Caple C997i Manual

3 Januar 2025
Inventum

Inventum IKI6045 Manual

2 Januar 2025