MODEL: PF1222TB1 SUBPANEL
TWO CIRCUIT POOL EQUIPMENT CONTROL WITH FREEZE AND HEATER PROTECTION
IN INDOOR/OUTDOOR ENCLOSURE
PANEL RATING: 60 AMP. 120/240 VOLT, 607 HZ.
This Pool Equipment Control is designed to automatically operate the Filter Pump, Cleaner Pump and also to provide
freeze protection for the pool equipment. Nevertheless this product is not intended to be a substitute for insulation,
coverings, or maintenance.
THE FILTER PUMP TIME SWITCH is located in the upper
left side of the enclosure and operates the Filter Pump, as
set by the trippers on the yellow dial, on a 24 hour
schedule. For setting the schedule, refer to page 3 of this
Manual.
THE FIREMAN SWITCH (heater protection mechanism) is
located next to the manual lever and its function is to stop
the heating process 20 minutes before the Time Switch
turns OFF the Filter Pump. By doing so, the circulating
water cools the heat exchanger thus preventing excess
heat build-up.
THE CLEANER PUMP TIME SWITCH is located in the
upper right side of the enclosure and operates the Cleaner
Pump (Booster Pump). The trippers of this Time Switch
should be set so that the operation of the Cleaner Pump
falls within the operation of the Filter Pump. To avoid
equipment damage, the two Time Switches are interlocked
and the Cleaner Pump would not operate unless the Filter
Pump is already operating.
THE FREEZE PROTECTION THERMOSTAT is located in
the lower left side of the enclosure and turns ON the Filter
Pump when the air temperature (where the Control Panel
is located) drops below the temperature set by the dial
(between 33˚F and 42˚F).
INSTALLATION
OPERATION &
SERVICE MANUAL
PF1000 SERIES
FREEZE PROTECTION CONTROLS
Risk of drowning!
Do not permit unsupervised children to use pool or spa.
Close supervision of children required at all times.
DANGER
Turn power off at main panel before servicing this switch or the equipment it controls. This control panel must be
installed according to the National Electrical Code and local code requirements. Use MIN 75˚C Copper conductors ONLY.
Install interchangeable circuit breakers with an interrupting current rating of 10000 symmetrical amperes, or higher.
Follow manufacturers instructions for installing and testing of ground fault circuit breakers (GFCB) and interrupters
(GFCI). Install only LISTED receptacle(s) and/or wiring device(s) inside the enclosure. When panel is outdoors, a LISTED
rainproof cover must be installed over the wiring device in the side knockouts. This control should not be connected
to any equipment which would cause bodily injury or property damage should it be activated unexpectedly.
Reinstall safety guard after wiring.
WARNING Risk of Fire or Electrical Shock
GENERAL INFORMATION


Produkt Specifikationer

Mærke: Intermatic
Kategori: Ikke kategoriseret
Model: PF1222TB1

Har du brug for hjælp?

Hvis du har brug for hjælp til Intermatic PF1222TB1 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Intermatic Manualer

Intermatic

Intermatic PRO2002403 Manual

16 December 2024
Intermatic

Intermatic ST01A Manual

16 December 2024
Intermatic

Intermatic PF1102MT Manual

16 December 2024
Intermatic

Intermatic PF1102M Manual

16 December 2024
Intermatic

Intermatic PF1222TB1 Manual

16 December 2024
Intermatic

Intermatic PF1103T Manual

16 December 2024
Intermatic

Intermatic T10101R Manual

16 December 2024
Intermatic

Intermatic PF1112T Manual

16 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

KeepOut

KeepOut FX900V2 Manual

16 December 2024
Makita

Makita CV101D Manual

16 December 2024
Aduro

Aduro H2 Lux Manual

16 December 2024
Ruggard

Ruggard EDC-180LC Manual

16 December 2024
Livarno Lux

Livarno Lux HG06843 Manual

16 December 2024
Livarno Lux

Livarno Lux HG05573 Manual

16 December 2024