Intermatic T30404R Manual


Læs nedenfor 📖 manual på dansk for Intermatic T30404R (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
T30000R SERIES
POOL/SPA EQUIPMENT CONTROLS
INSTALLATION
OPERATION &
SERVICE MANUAL
C
C
C
C
C
O
O
O
O
O
N
N
N
N
N
T
T
T
T
T
R
R
R
R
R
O
O
O
O
O
L
L
L
L
L
P
P
P
P
P
A
A
A
A
A
N
N
N
N
N
E
E
E
E
E
L
L
L
L
L
W
W
W
W
W
I
I
I
I
I
T
T
T
T
T
H
H
H
H
H
T
T
T
T
T
I
I
I
I
I
M
M
M
M
M
E
E
E
E
E
S
S
S
S
S
W
W
W
W
W
I
I
I
I
I
T
T
T
T
T
C
C
C
C
C
H
H
H
H
H
F
F
F
F
F
O
O
O
O
O
R
R
R
R
R
I
I
I
I
I
N
N
N
N
N
D
D
D
D
D
O
O
O
O
O
O
O
O
O
O
R
R
R
R
R
/
/
/
/
/
O
O
O
O
O
U
U
U
U
U
T
T
T
T
T
D
D
D
D
D
O
O
O
O
O
O
O
O
O
O
R
R
R
R
R
U
U
U
U
U
S
S
S
S
S
E
E
E
E
E
Suitable for Pool Equipment Control and for Direct Connection of Underwater Lights
ELECTRICAL RATINGS: See inside Enclosure Door
Many of today’s energy efficient pools and spas
utilize the advantages of a single electrical panel,
containing all the necessary controls for the safe,
efficient and automatic operation of the pool/spa
equipment. In addition, this Panel can also be
used to control any outdoor equipment, sign or
pump within its rated capacity.
The all-weather enclosure contains none one or
two heavy-duty, industrial grade Time Switches.
Also, it has provisions to install switches or a
GFCI receptacle on the side as well as the inside.
The Time Switch can also accommodate an
optional heater control (fireman) switch.
The Control is designed to operate any pump,
within its rated capacity. However, if protection
to prevent dry start is required by the pump
manufacturer, it must be provided in addition
to this Control. Contact pump manufacturer
if not sure and/or for more details.
1
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician.
...always disconnect electricity before servicing this control or the equipment connected to it.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
I
I
I
I
I
N
N
N
N
N
T
T
T
T
T
E
E
E
E
E
R
R
R
R
R
M
M
M
M
M
A
A
A
A
A
T
T
T
T
T
I
I
I
I
I
C
C
C
C
C
I
I
I
I
I
N
N
N
N
N
C
C
C
C
C
O
O
O
O
O
R
R
R
R
R
P
P
P
P
P
O
O
O
O
O
R
R
R
R
R
A
A
A
A
A
T
T
T
T
T
E
E
E
E
E
D
D
D
D
D
,
,
,
,
,
SPRING GROVE, IL 60081-9698
http://www.intermatic.com
158TP10425 4
WARRANTY
If within one (1) year from the date of installation, this product fails due to a defect in material or workmanship, Intermatic Incorporated
will repair or replace it free of charge.
The warranty does not cover labor for removal or reinstallation and does not apply to: (a) damage caused by accident, abuse, mishan-
dling, or dropping; (b) a unit which has been subject to unauthorized repair; (c) units not used in accordance with directions; (d) damages
exceeding the cost of the product. Some states do not allow a limitation of damages so the foregoing warranty may not apply to you. This
warranty gives you specific legal rights and you may also have other rights which vary from state to state.
This warranty service is available, if the defective product or its defective component is returned with proof of purchase and date of
installation, either (a) to the dealer from whom the unit was purchased or (b) by shipping prepaid to the Intermatic Incorporated/After Sales
Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000 http://www.intermatic.com
WIRING DIAGRAM
Typical 120 Volt Installation Typical 240 Volt Installation
Filter and Cleaner Timer Inter-Connections
NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details.
2. Diagrams above are only two of the many variations this Panel can accommodate.


Produkt Specifikationer

Mærke: Intermatic
Kategori: Ikke kategoriseret
Model: T30404R

Har du brug for hjælp?

Hvis du har brug for hjælp til Intermatic T30404R stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Intermatic Manualer

Intermatic

Intermatic PF1103 Manual

17 December 2024
Intermatic

Intermatic T10004R Manual

17 December 2024
Intermatic

Intermatic PRO2002403 Manual

16 December 2024
Intermatic

Intermatic ST01A Manual

16 December 2024
Intermatic

Intermatic PF1102MT Manual

16 December 2024
Intermatic

Intermatic PF1102M Manual

16 December 2024
Intermatic

Intermatic PF1222TB1 Manual

16 December 2024
Intermatic

Intermatic PF1103T Manual

16 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024