JANDY Hot Shot Manual

JANDY Varmeapparat Hot Shot

Læs nedenfor 📖 manual på dansk for JANDY Hot Shot (2 sider) i kategorien Varmeapparat. Denne guide var nyttig for 5 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Pressure
Switch
Thermistor
Pilot
Pilot
Generator
Fusible
Link
Hi-Limit
135° F Hi-Limit
(150° F)
Gas Valve
Temperature Control
Orange
Red
SENSENPOTPOT
TH/PP
+
(PP)
Valve
(TH)
Red
Red
White
Black
TP/TH
TH
TP 1
2
Black
Black
3a 3b
4a
5a
Black to TH
Yel
low
to T
P
White to TP/TH
Red to TP
Laars
5b
Piezo Ignitor
Black
Pilot Coil
4b
Try to light the pilot.
Does pilot light?
Does pilot stay on
when gas valve
knob is released?
500+ mV @ PP
and PP-TH
terminals? (1)
1. Verify gas is on.
2. Check for air in gas line.
3. Is pilot tube clogged?
If voltage is found at one and not
the other, replace Fuse Link. Check
for Roll out, Soot, Downdrafting,
Low Gas Pressure, etc.
No
1. Check P/G output (1) .
2. Check for shorted wires.
3. Check pilot coil.
1. Check for low Pilot Generator
output.
2. Check for partial shorts
or loose wires.
3. Replace Pilot Generator.
500+ mV @
and both terminals
of Fuse Link? (2)
500+ mV @ Red
Wire of Pressure
Switch going to
rocker switch? (4b)
Perform Back Pressure Test. If
2.5 PSI or more, replace switch.
If less, check pump, filter, etc.
for pressure problem.
500+ mV @ Red wire
of from Hi-Limits to
Pressure Switch (4a)
1. Check each High Limit
individually. (3a&b)
2. Check if damage to
bypass or heat exchanger.
Set gas valve knob to pilot position.
Set rocker switch to OFF.
Set rocker switch to ON
Is there 200+ mV
@ Red wire of
Pressure Switch? (4b)
Yes
Is there 200+ mV
@ TH terminal of
the Gas Valve?
No
Is there 500+ mV
@ TH/PP on
Temp. Board?
Yes
Move rocker switch
to OFF. Rotate Gas
Valve Knob to ON.
Move rocker switch
to ON. Does heater fire?
Is there 500+ mV
@ Valve (TH) on
Temp. Board?
No
Yes
Yes
Is there 500+ mV
@ TH terminal of
Gas Valve?
Yes
Replace
Gas Valve
No
Yes
Yes
Yes
Yes
Yes
No
No
Check and/or replace
black wire from
Valve (TH) terminal
of Temp. Board and
TH terminal of Gas Valve.
No
Perform Thermistor Test, see below.
Replace Temp. Board
Check rocker
switch
Yes
No
Yes
No
No
No
No
No
Disconnect Pot wires and jump pot
terminals. If voltage drops to 200+ mV,
replace Temp. Control (P/N
R0058200).
Mat #0754, Rev. C 09/05
HOT SHOT (100K) HEATER TROUBLESHOOTING


Produkt Specifikationer

Mærke: JANDY
Kategori: Varmeapparat
Model: Hot Shot

Har du brug for hjælp?

Hvis du har brug for hjælp til JANDY Hot Shot stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat JANDY Manualer

JANDY

JANDY Legacy Manual

21 August 2024
JANDY

JANDY CXI650NN Manual

20 August 2024
JANDY

JANDY Hi-E2 Manual

20 August 2024
JANDY

JANDY Lite2 Manual

19 August 2024
JANDY

JANDY LXi Manual

18 August 2024
JANDY

JANDY CXI500NN Manual

17 August 2024
JANDY

JANDY CXI650PN Manual

17 August 2024
JANDY

JANDY XL 3 Manual

17 August 2024
JANDY

JANDY CXI750NN Manual

16 August 2024

Varmeapparat Manualer

Nyeste Varmeapparat Manualer

Yamazen

Yamazen YDH-M10 Manual

18 November 2024
Yamazen

Yamazen HF-J126 Manual

18 November 2024
Yamazen

Yamazen DSF-VW12 Manual

18 November 2024
Yamazen

Yamazen DHF-S121 Manual

18 November 2024
Yamazen

Yamazen DSF-VN123 Manual

18 November 2024
Taurus

Taurus Tuareg 2000 Manual

16 November 2024
Qlima

Qlima DFA 2330 Manual

16 November 2024
Trotec

Trotec TDE 25 Manual

16 November 2024
Alpina

Alpina GS 1500 Manual

15 November 2024