Side 1/1
The JA-80F wireless keypad MLH51300 1
The JA-81F wireless keypad
The JA-81F is a component of Jablotron’s OASiS alarm system and is designed to
control and program the system. It has a built-in proximity access card reader and
allows the wiring up of a separate door detector. The battery-powered keypad
communicates wirelessly using OASiS protocol.
Installation
Installation shall only be undertaken by technicians holding a certificate
issued by an authorized distributor. The keypad is for indoor installation only,
typically by the main entrance door. Avoid locating it close to metal objects,
which could shield radio communication.
1. Open the keypad housing (by pressing the tab on the bottom) using a
screwdriver. The tab is also accessible from the front after opening the key
cover.
1. Install the rear housing to the desired location
2. Install the external hard-wired detector (if required) route its cable
through the rear housing and connect to the IN and GND terminals.
3. Enroll the keypad to the control panel (see the control panel
installation manual) as follows:
Enter enrollment mode in the control panel (if the system does not
have a keypad already, briefly short the reset link on the control panel
main board, or if a keypad is present, then press key 1 in service
mode).
Install the battery into the keypad to trigger enrollment.
Exit enrollment mode by pressing the # key.
4. Attach the keypad to the rear housing.
5. Instructions on how to use the keypad can be found in the control panel
operating manual.
Keypad menu
The menu can be entered in Service mode by holding the ? key. Then the
internal keypad menu will be displayed. Using the arrows on keys 1 and 7 you
can scroll through the menu:
Display Key Description
Tamper ON ¾ Disable / Enable the tamper sensor
(only for service purposes)
Door chime ON ¾ Disable / Enable sound when IN triggered
Beeper ON ¾ Disable / Enable system sounds
Brightness  Sets the display brightness 0 - 9
Contrast  Sets the display contrast 0 - 9
Edit text ¾ Entry to keypads text editing
English ¾ Sets English (reload default texts)
Čeština ¾ Other languages ...
To exit the menu, press # (exiting also occurs after 10 seconds’ inactivity).
Notes:
The menu can be displayed even if the keypad has not been enrolled to the
control panel.
Each keypad has its own menu, i.e. each keypad in the system can have its
own unique settings.
The keypad keeps its settings even if its power is disconnected (settings can
only be altered via the keypad menu).
The menu can also be entered when the ¾key is kept pressed while the
keypad is being powered-up.
Keypad sleep mode
When battery-powered, the keypad saves energy by turning itself off when the
cover is closed or automatically after 20 seconds of inactivity (15 minutes in service
mode). The keypad is woken up by: opening the keypad‘s flip cover, pressing any
key, or triggering the wired door detector input - see below.
Optional AC adapter
If the keypad is powered by an AC adapter (model: Jablotron DE01-12 for
terminals: +U and GND), it will not turn off after 20 seconds of inactivity. If the
adapter is used, batteries should still be installed. Only turn on the AC adapter
after the keypad unit has been powered up by batteries and the two halves of
the housing are back together.
Note: To comply with EN standards the keypad does not indicate the status of
the alarm system. If desired, the system setting / unsetting status can be
programmed in the control panel to be permanently indicate by the keypad.
Installing a door detector
It is possible to wire up a detector(s) to the keypad. The IN input terminal is
triggered when disconnected from GND. The control panel’s reaction to the IN input
being triggered is a delayed intruder alarm linked to the keypad‘s address. If
desired, another reaction can be programmed in the control panel. The IN input can
indicate a door being permanently open (status reaction). If the IN input is not used
then it must be shorted to GND.
123
ABC
456
A
789
ON
0 #
B
?
OFF
ESC
ABC
OASiS
IN
GND
+U
Note: The lifetime of the battery is reduced proportionally to how frequently the
door detector is triggered and how often and how long the keypad is battery-
powered.
Testing keypad communication
In service mode, the control panel allows you to measure the keypad’s radio
signal strength. To test the keypad signal, trigger either its IN input or its
tamper sensor.
Note: the control panel measures the strength of the signal transmitted by the
keypad. It is impossible to measure the signal strength received by the keypad
from the control panel. If the keypad has lost communication with the control
panel (e.g. if the control panel is damaged) it would display COMM ERROR a
communication error. If you re-power a control panel, which previously worked
with a keypad, and the keypad does not function, then we recommend
disconnecting and re-connecting the keypad batteries.
Controlling the PgX output
The PgX output can be switched ON and OFF by pressing the ON (¾) and
OFF (#) buttons long (for 5 seconds). The function of PgX must be set in the
control panel. A long beep confirms the change of the output’s state.
Keypad text editing
The most convenient way to edit text is to use a PC running OLink software.
To transfer edited text from a PC to the keypad, the keypad (with its batteries
installed) has to be connected either to the OASiS system‘s digital bus (i.e.
one cable from the keypad to the control panel, and another cable from the
control panel to the PC) or directly from the PC. The texts are transferred by
choosing the Save menu in the Texts window in OLink software.
The names can be edited via the keypad in the “Edit Text” menu item see
the control panel installation manual. The edited text is only stored in the
keypad unit used for editing.
Battery replacement
The system checks the battery status and if discharged it will inform the user or
the installer. The keypad will continue to work but will also indicate a low
battery as well as the backlight being reduced. Batteries should be replaced
within 2 weeks by a qualified technician in service mode. If they are not, the
keypad is switched off when the battery power falls under a critical limit.
Note: Both batteries must be always changed together and with
identical types (manufacturer).
Removing the keypad from the system
If the keypad is removed from the system, the control panel indicates this
event. If you want to uninstall the keypad, it must also be erased in the control
panel.
Technical specifications
Power supply 2x lithium batteries type CR123A (3.0V)
Typical battery lifetime approx. 3 years (with a max.of 2 daily activations)
Communication frequency 868 MHz, OASiS protocol
Communication range approx. 100m (open area)
RFID cards Jablotron PC-01 or PC-02 (EM UNIQUE 125kHz)
Door detector input IN = normally closed loop
Dimensions 120 x 130 x 30 mm
Environment according to EN 50131-1 II. internal
Operating temperature range -10 to +40 °C
EN 50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 classification 2
Complies with ETSI 300220, ETSI 300330, EN 50130-4,
EN 55022, EN 60950-1
Can be operated according to ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-80F is in compliance
with the essential requirements and other relevant provisions of Directive
1999/5/ECThe original of the conformity assessment can be found at
www.jablotron.com , Technical Support section.
Note: Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer
after use.


Produkt Specifikationer

Mærke: Joblotron
Kategori: Overvågningskamera
Model: JA-81F

Har du brug for hjælp?

Hvis du har brug for hjælp til Joblotron JA-81F stil et spørgsmål nedenfor, og andre brugere vil svare dig




Overvågningskamera Joblotron Manualer

Overvågningskamera Manualer

Nyeste Overvågningskamera Manualer

Sony

Sony SNC-DH160 Manual

16 November 2024
Bresser

Bresser DL-30MP Manual

15 November 2024
D-Link

D-Link DCS-6500LHV2 Manual

14 November 2024
D-Link

D-Link DCS-2803KT Manual

13 November 2024
D-Link

D-Link DCS-2804KT Manual

13 November 2024
D-Link

D-Link DCS-931L Manual

13 November 2024
D-Link

D-Link DCS-6100LHV2 Manual

13 November 2024
Emos

Emos H4060 Manual

13 November 2024