Joblotron WJ-80 Manual


Læs nedenfor 📖 manual på dansk for Joblotron WJ-80 (1 sider) i kategorien Overvågningskamera. Denne guide var nyttig for 24 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
The WJ-80 interface for an outdoor keypad / reader MKM51002
1
The WJ-80 interface for an outdoor keypad / reader
The WJ-80 is a component of Jablotron’s JA-80 Oasis 80 system. It is
designed to connect JA-80H outdoor keypads or JA-80N RFID readers to a
control panel. It provides an output to operate the electric strike of a door lock
and is equipped with a wireless door bell transmitter.
The WJ-80 can also be used to interface to a third party keypad (reader)
which uses Wiegand 26b protocol (e.g. HID RK-40 a RK-10).
Installation
Installation shall only be undertaken by technicians holding a certificate
issued by an authorized distributor. It should be placed in a protected internal
part of a house (usually near an entrance door equipped with an electric
lock).
Open the front cover by unscrewing the screw and take out the electronic circuit
board (held by 2 tabs). Install the back part of the housing to the desired place, put
back the electronic circuit board and connect the cables see the following diagram.
Do not connect the power before all wiring up and setting the DIP switches has been
finished.
Terminals
Tamper switch
ON
1 2 3 4
DIP
switches
Terminals for
keypad
or reader
JA-80H
JA-80N
Termina ls
for
external lock
system
bus
OASiS
Re
5A
Control panel (C.P.) bus cable
+U, B, A, GND connect to the corresponding terminals in the C.P.
Keypad/reader cable a max. of one JA-80H or JA-80N can be wired in
terminal wire
+12V red (power, max. 60mA)
D0 green (DO data of Wiegand 26b)
D1 brown (D1 data of Wiegand 26b)
TMP grey (TAMPER input, triggers if disconnected from GND)
BZR yellow (output to operate the keypad buzzer by grounding it,
max. 10mA)
GND blue and white (ground)
OPN unlock input grounding this terminal activates the output
relay for a period selected by DIP switch # 3. Can be used as a
push button input to open the door from the inside.
A third party keypad/reader can be used if it uses Wiegand 26b protocol, but
Jablotron cannot guarantee its compatibility.
Electric door lock output
+E , GND a power supply to activate the electric strike of a door lock (its
long-term current is limited by a resistor and its initial energy
pulse is supplied by a reservoir capacitor). The power output
is optimised for door locks of the type Jablotron Z8-12V.
C and NO normally open dry contact of the output relay (max. 5A / 60V)
DIP switches
Interface features can be set by the DIP switches:
# OFF ON
1 the keypad (reader) works as a
control panel (CP) keypad. The
output relay can be activated by a
PGY output (if DIP #2 is on)
the keypad (reader) only operates
the door lock and starts a CP
entrance delay if the CP is set
(armed). The output relay is activated
by a valid code (card) entry on the
connected keypad.
2 no reaction to PGY reacts to the PGY output of CP relay output
3 relay energizes for 3 sec. 6 sec. relay energizes for
4 no entrance and exit beeps from
the connected keypad
exit and entrance beeps enabled*
* disconnect the yellow wire from the BZR terminal to switch the keypads acoustic
and optical indication off completely.
The connected keypad / reader function
For the WJ-80 to function properly, the control panel should have its back-up
battery connected. The basic function of the keypad / reader is determined by DIP
switch # 1:
OFF = the keypad / reader works as a control panel keypad and can therefore be
used to operate and program the alarm system. The output relay can only be
activated in this mode by the CPs programmable PGY output (if DIP switch # 2 is
ON, the duration of relay activation is set by DIP switch # 3).
ON = the keypad / reader only operates the door lock (external bypass function). It
means:
The door lock opens by: a valid code (card) entry, grounding the OPN terminal and, if
DIP # 2 is on, then also by triggering the PGY output (this can be used to open the
door by entering 9 on the control panel keypad).
If the door lock opens (by any of the above ways) while the alarm system is set, the
entrance delay will start (as if a delayed detector has just been triggered).
When the external keypad / reader is in this mode it cannot be used to set, unset or
program the alarm system. It can however be used to program access codes
(cards) the same way as via the control panel keypad (by the 6 sequence).
If operation of the control panel by the service code (sequence 6921 in the
control panel) is enabled, then the service code cannot be used for door
opening.
The JA-80H’s door bell button
The bottom left key on the keypad can be used as a door bell button if the
JA-80L wireless siren has been installed. If this function is desired, the button should
be enrolled to the JA-80L siren (by pressing it while the siren is in enrollment mode).
If the door bell button is used, the WJ-80 housing should not be shielded by any
metal which could block radio signals.
Configuring the keypad for operation with the WJ-80
If the JA-80H keypad or JA-80N reader is connected to an Oasis control
panel via a WJ-80 unit and it does not work as described above, then it is not
set to the correct (factory default) operational mode. In such a case, follow
the keypad / reader manual.
Example of wiring
Exit button
at building exit
electric
door lock
Z8-12V
JA-80H
keypad
or
JA-80N
reader
OASiS
system
bus
Re
5A
Specifications
Power via the control panel bus
Standby consumption approx. 60mA (incl.JA-80H or 80N)
Output relay contact max. 5A/60V
Built-in doorbell transmitter 868MHz, Oasis protocol
Operational environment II. indoor general, –10 to +40 °C (EN50131-1)
WJ-80 dimensions 76 x 110 x 33 mm
EN 50131-1, EN 50131-5-3 Grade 2
Can be operated according to ERC REC 70-03
FCC ID VL6WJ80
Jablotron Ltd. hereby declares that the WJ-80 is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC and complies
with part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept
any interference received, including interference that may cause undesired
operation.
CAUTION: Changes or modifications no expressly approved by Jablotron could
void the user´s authority to operate the equipment. The original of the conformity
assessment can be found at www.jablotron.com
, Technical Support section.


Produkt Specifikationer

Mærke: Joblotron
Kategori: Overvågningskamera
Model: WJ-80

Har du brug for hjælp?

Hvis du har brug for hjælp til Joblotron WJ-80 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Overvågningskamera Joblotron Manualer

Overvågningskamera Manualer

Nyeste Overvågningskamera Manualer

Sony

Sony SNC-DH160 Manual

16 November 2024
Bresser

Bresser DL-30MP Manual

15 November 2024
D-Link

D-Link DCS-6500LHV2 Manual

14 November 2024
D-Link

D-Link DCS-2803KT Manual

13 November 2024
D-Link

D-Link DCS-2804KT Manual

13 November 2024
D-Link

D-Link DCS-931L Manual

13 November 2024
D-Link

D-Link DCS-6100LHV2 Manual

13 November 2024
Emos

Emos H4060 Manual

13 November 2024