Water Supply Potable City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33° - 100°F (0.6° - 37.8° C)
Service Flow Rate 0.50 GPM (1.89 L/min.) @ 60 psi.
PERFORMANCE DATA SHEET
System tested and certified by NSF International against NSF/
ANSI Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specified on the Performance Data Sheet.
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction 97.5%
Particulate Class I* At least 10,000 particles/mL 85% reduction 99.7%
Cysts50,000/L min. >99.95% 99.99%
Turbidity 11 NTU ± 1 NTU 0.5 NTU 98.9%
Asbestos 107 to 108 bers/L†† > 99% 99%
Lead***: @ pH 6.5 0.150 mg/L ± 10% 0.010 mg/L 99.3%
Lead***: @ pH 8.5 0.150 mg/L ± 10% 0.010 mg/L 98.8%
Mercury: @ pH 6.5 0.006 mg/L ± 10% 0.002 mg/L 95.3%
Mercury: @ pH 8.5 0.006 mg/L ± 10% 0.002 mg/L 89.7%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 94.1%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 96.8%
p-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.7%
Toxaphene 0.015 mg/L ± 10% 0.003 mg/L 93.8%
2, 4-D Reduction 0.210 mg/L ± 10% 0.07 mg/L 90.7%
Atenolol 200 ng/L ± 20% 30 ng/L >97.0%
Linuron 140 ng/L ± 20% 20 ng/L >96.2%
Trimethoprim 140 ng/L ± 20% 20 ng/L >96.2%
Estrone 140 ng/L ± 20% 20 ng/L >96.4%
Meprobamate 400 ng/L ± 20% 60 ng/L 95.0%
Carbamazepine 1400 ng/L ± 20% 200 ng/L >98.5%
DEET 1400 ng/L ± 20% 200 ng/L >98.5%
Metolachlor 1400 ng/L ± 20% 200 ng/L 97.0%
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter Part #46 9083. 2016 suggested retail price of $54.99
U.S.A./$54.99 Canada. Prices are subject to change without notice.
The filter monitor system measures the amount of water that passes
through the filter and alerts you when it is time to replace the filter. To learn
how to check the water filter status, see “Using the Controls” or “Water
Filtration System” in the User Instructions or User Guide.
After changing the water filter, flush the water system. See “Water and Ice
Dispensers” or “Water Dispenser” in the User Instructions or User Guide.
These contaminants are not necessarily in your water supply. While testing
was performed under standard laboratory conditions, actual performance
may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and local laws
and regulations.
* Class I particle size: >0.5 to <1 um
*** Compliant for Lead reduction requirements under NSF/ANSI
Standard 53 as tested by Pace Analytical Services, Inc.
Based on the use of Cryptosporidium parvum oocysts
†† Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C
to 22°C). Rated service capacity, WF-NLC240V = 240 gallons (908 liters) .
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certified
for cyst reduction may be used on disinfected waters that may contain
filterable cysts. EPA Est. No. 91736-MEX-001
Refer to the “Warranty” section for the Manufacturer’s limited warranty,
name and telephone number.


Produkt Specifikationer

Mærke: Kenmore
Kategori: Ikke kategoriseret
Model: 9085

Har du brug for hjælp?

Hvis du har brug for hjælp til Kenmore 9085 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Kenmore Manualer

Kenmore

Kenmore KKAF8Q Manual

18 November 2024
Kenmore

Kenmore KW4010 Manual

2 November 2024
Kenmore

Kenmore CU7001 Manual

2 November 2024
Kenmore

Kenmore BU4018 Manual

2 November 2024
Kenmore

Kenmore DS4030 Manual

1 September 2024
Kenmore

Kenmore KW3010 Manual

1 September 2024
Kenmore

Kenmore DU5080 Manual

1 September 2024
Kenmore

Kenmore KW3030 Manual

1 September 2024
Kenmore

Kenmore DU4080 Manual

1 September 2024
Kenmore

Kenmore DS4090 Manual

1 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024