A
WM2
P
AWM2P
MICROMODULE
20262 / 20101011 • AWM2PT M
© ALL RIGHT S RE SE RVED MA RMITE
LAUNAM RESU 3
2 © MARMITEK
1
ENGLISH
1. Phase clamp (230V)
2. Load clamp
3. Neutral clamps
4. Indicator light (LED)
5. Set up button
6. Wire connections to wall switches
MICROMODULE AWM2P
NEDERLANDS
1. Fase aansluiting (230V)
2. Aansluiting voor belasting
3. Nulklemmen
4. LED indicator
5. Programmeerknopje
6. Aansluitdraden voor schakelaars
23
4
5
6
3AWM2P
ENGLISH
MARMITEK MICROMODULE AWM2P
Marmitek X-10 transmitter for 2 addresses with a built-in
appliance module.
SAFETY WARNINGS
The wiring of your electrical installation is live (230 V) and
extremely dangerous. Never connect the module when plugged
into the mains. Always turn off the main switch before starting
the installation.
This product is for professional use and should be installed by a
certified installer.
To prevent short circuits, this product should only be used inside and
only in dry spaces. Do not expose the components to rain or moisture.
Do not use the product close to a bath, swimming pool etc.
Do not expose the components of your systems to extremely
high temperatures or bright light sources.
In case of improper usage or if you have altered and repaired
the product yourself, all guarantees expire. Marmitek does
not accept responsibility in the case of improper usage of the
product or when the product is used for purposes other than
specified. Marmitek does not accept responsibility for additional
damage other than covered by the legal product responsibility.
This product is not a toy. Keep out of reach of children.
Do not open the product: the device may contain live parts.
The product should only be repaired or serviced by a qualified
repairman.
Automatic switching devices provide comfort, but can also
be dangerous. They can surprise people or can ignite clothing
hanging over an electric heat source. Please be careful and take
appropriate measures to avoid accidents.
HOW DOES MARMITEK X-10 WORK?
Marmitek X-10 components use the existing mains wiring to
communicate (using Marmitek X-10 signals). You can build a
complete system using the three different kind of components of
the Marmitek X-10 System:
4 © MARMITEK
1. Modules
These components will receive Marmitek X-10 signals and will switch
or dim the attached lamp or appliance.
2. Controllers
These components will transmit Marmitek X-10 signals and thus will
control the Modules.
3. Transmitters
Wireless components like remotes. The signals of these components
will be received by a controller with transceiver functionality (IRRF
7243, TM13, CM15Pro or console of a Marmitek SecuritySystem).
The Transceiver will translate the signals into Marmitek X-10 signals
on the power line.
ADRESSES
Up to a maximum of 256 different addresses can be preset. These are
subdivided into a so-called HouseCode (A to P incl.) and a UnitCode
(1 to 16 incl.). The HouseCode can also be set on the controllers, so
that the controllers and modules become part of the same system.
The address can be set either using code dials or by pressing buttons,
depending on the type of module.
The Marmitek X-10 System uses standard commands, which control
all units with the same HouseCode at the same time (e.g. all lights
on, all off, etc.).
SIGNAL RANGE
Range of Marmitek X-10 signals over the Power Line and how
to increase the range.
The Marmitek X-10 System is based on power line communication. The
range of the Marmitek X-10 signals very much depends on the local
circumstances. On average the range is a cable length of 80 meters.
If you have difficulties with the range of your Marmitek X-10
signals, please pay attention to the following facts:
1. When several phases are used in the house, it can be necessary
to couple these phases for Marmitek X-10 signals. You can
5AWM2P
ENGLISH
couple them with the use of a CAT 3000 active 3 phase coupler/
repeater (Art.No. 09304) and it is required if wall outlets and
lighting points are actually divided into several phases (several
groups is no problem for the Marmitek X-10 signal).
2.
It is possible that Marmitek X-10 signals are attenuated by devices
and lights which are connected to the power line. In a normal home
situation this effect is negligible (the Marmitek X-10 system is using
active gain control to eliminate the effects). However, it is possible that
a particular device in your house is attenuating the signals so much
that the range of Marmitek X-10 signals is decreased significantly.
When you have range problems, it is wise to try to locate the device
which is attenuating the signals simply by unplugging devices from
the power line, and testing the differences in range for your Marmitek
system. When e.g. your conclusion is that e.g. your computer monitor
is attenuating the signal, you can use a FM10 Plug-in Filter between
the power line and the monitor to eliminate the effects.
Known devices which can cause attenuation are:
PC Monitors
PCs with heavy internal power supplies
Old Televisions
Copiers
Fluorescent Lights
Gas Discharge Lamps (Energy Saving Lamps)
3. Some (old) devices are able to disturb the signal by transmitting
noise on the power line. Because the Marmitek X-10 signals are
transmitted on 120 kHz, only noise on or near this frequency
will have influence on the range. When you use a FM10 Filter to
connect this device to the power line, the noise will be filtered.
4. The Marmitek X-10 protocol has several mechanism to avoid
modules to be switched on or off by other sources than your
Marmitek X-10 Controllers. However, it is possible that the
6 © MARMITEK
Marmitek X-10 signals are disturbed by e.g. baby phones which
are in TALK mode (continuous transmission). When these kind
of signals are present on the power line it is possible that the
Marmitek X-10 signals will not come through.
5.
The mains do not stop at the front door of your home. Everything
that is attached to mains nearby your home can have influence on
Marmitek X-10 signals (e.g. heavy machinery). If you think that your
system is influenced by devices out of your house, it is advisable to
install FD10 Phase Coupler/Filter on each phase entering the house.
These filters will block signals coming into or going out of your
house, but will also match the impedance for the mains. Hereby
make your house Marmitek X-10 compatible for these units. To
couple the phases use a CAT 3000, see point 1 above.
INSTRUCT IONS FOR USE
APPLICATIONS/CHAR ACTERISTICS
Because of its extremely small proportions the module can be
built in behind built in switches and wall outlets (minimal depth
flush switch with box 40mm, preferred: 50mm). The module is
also ideal for building in light armatures and for installing in small
spaces with for instance lowered ceilings.
Multi-purpose: fully free choice, colour and model of switch
material.
To this module two switches can be connected. One controls
the internal appliance module, but also controls the matching
X-10 command through the power line. With the second switch
ON/OFF commands can be sent for a second X-10 address.
The address to be set up can be programmed through the power
line with every Marmitek X-10 remote control (e.g. Marmitek
EasyControl8™ remote control withTM13 transceiver).
The AWM2P can react to one or more group commands (ALL
LIGHTS ON, ALL UNITS OFF). These functions are disabled by
default.
7AWM2P
ENGLISH
The AWM2P supports two way Marmitek X-10 communication.
Both normal switches (on-off) and Momentary switches can be
connected to the module. These are automatically recognized by
the AWM2P.
This module is suitable for installing two-way switches without
wiring between the switches (MicroModules pass on their status
to other MicroModules).
The AWM2P can control Macro’s/Scenario’s by operating a
conventional switch (with for instance Marmitek ActiveHomePro).
The internal appliance module remembers its status after a main
voltage cut-off.
Colour code wire connections
WARNING: THE WIRES OF THE MICROMODULE CARRY THE LIFE
DANGER 230V MAIN- VOLTAGE!! ALWAYS SWITCH OFF THE MAIN
MASTER SWITCH BEFORE INSTALLING THE MICROMODULE.
Description of the Marmitek MicroModule wires
Purple: Input 1, programmed base address + control of the
built-in appliance module
The built-in appliance module will switch from ON to OFF or vise
versa when the purple wire is connected with the phase wire. At
the same time the programmed address will transmit the new
status of the appliance module through the power line. Due to this
Marmitek X-10 transmission you are able to switch other Marmitek
X-10 modules (set to the same address). The new status will also
be recognized by other MicroModuls or e.g. the computer interface
(activating macro’s, status indication and more).
8 © MARMITEK
White: Input 2, second address
When the red wire is connected to the phase wire, the programmed
address +1 will be transmitted (e.g. when A3 is programmed as the
base address then the Marmitek X-10 address A4 will be sent by using
input 2). If the status in the MicroModule was ON, an OFF command
will be transmitted. If the status in the MicroModule was OFF, an
ON command will be transmitted. Through this transmission, other
Marmitek X-10 modules can be switched remotely over the power
line or Macro’s setup in the computer interface can be activated.
Mounting Instructions
WARNING! ALWAYS SWITCH OFF THE MAIN MASTER SWITCH
BEFORE INSTALLING THE MICROMODULE.
To install the MicroModule AWM2P the following wiring is
required.
1. Neutral
2. Phase 230V
3. Load. This wire runs directly to the load.
Figure 1
Take the present switch (if one is installed) out of the wall outlet
box.
Disconnect all wires from the switch.
Pull an additional Neutral-wire in case this one is missing.
P
Blue (N) Brown
(L)
Black
9AWM2P
ENGLISH
Figure 2
Connect the phase, neutralize and load wire to the terminals of
the MicroModule AWM2P.
Connect the thin wires of the built-in module to the wall switch.
Connect the phase wire to clamp P of the wall switch.
Figure 3
Position the MicroModule against the back wall of the wall outlet
behind all the wires.
You are now able to program the MicroModule. For more
information see chapter “Programming”.
P
PROG.
NL
AWM2P
P
white
PROG.
NL
AWM2P
Brown
(L)
Blue (N)
Brown (L)
Black
Purple
10 © MARMITEK
Figure 4
Install the wall switch at its original place after the MicroModule
is programmed.
Please note: due to heat generation, apply no more than one module
per flush socket / central socket!
Programming
WARNING: DO NOT FORGET TO TURN ON THE MAIN MASTER
SWITCH PRIOR TO PROGRAMMING.
Activate the setup mode.
The following steps have to be taken to start the setup procedure for
programming the MicroModule:
Press the setup (prog.) button for at least 3 seconds (see figure
5). The LED should stay on after releasing the setup button.
Warning! The MicroModule will leave the setup mode if it
doesn’t receive any commands within 60 seconds.
Exit setup mode
Press the setup button once shortly; The red LED will turn off
now. You can also wait for at least 60 seconds so that the
MicroModule will exit the setup mode automatically.
prog.
SAIX
prog.
SAIX
11AWM2P
ENGLISH
Figure 5
Activate or exit the setup mode.
Programming the X-10 address and the various options
The chart below shows the various possibilities to program the
MicroModule AWM2P
defaults Programmable Command Light blinks
Address A1 Address A2 to P16 2x Address 2x
Doesn’t respond to
All Lights On”
Responds to “All
Lights On”
2x “All lights on” 2x
Doesn’t respond to
All Units Off”
Responds to “All
Units Off”
2x “All Units Off” 4x
For programming the Marmitek X-10 address and options you will be
able to use any Marmitek X-10 controller or remote control. For the
following explanation we used a Marmitek 8-in-1 remote control to
P
PROG.
NL
AWM2P
PROG.


Produkt Specifikationer

Mærke: Marmitek
Kategori: Ikke kategoriseret
Model: AWM2P
Opbevaringstemperatur (T-T): -20 - 70 °C
Driftstemperatur (T-T): -10 - 35 °C
Dimensioner (BxDxH): 46 x 46 x 16 mm
Indgangsspænding: 230 V
Indgangsfrekvens: 50 Hz
AC udgange, antal: - AC stikkontakt(er)

Har du brug for hjælp?

Hvis du har brug for hjælp til Marmitek AWM2P stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Marmitek Manualer

Marmitek

Marmitek LM15 Manual

7 Oktober 2024
Marmitek

Marmitek Connect TS21 Manual

17 September 2024
Marmitek

Marmitek Glow MI Manual

21 August 2024
Marmitek

Marmitek IRRF7243 Manual

16 August 2024
Marmitek

Marmitek Split 422 Manual

15 August 2024
Marmitek

Marmitek Split 412 Manual

14 August 2024
Marmitek

Marmitek AMM31 Manual

12 August 2024
Marmitek

Marmitek DAIX12 Manual

12 August 2024
Marmitek

Marmitek SAX4 Manual

11 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer