OVER TEMPERATURE
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 17 units (circuit breaker of type B) / 28 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL LPH-18-12 LPH-18-36LPH-18-24
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
12V 36V24V
1.5A 0.5A0.75A
0 ~ 1.5A 0 ~ 0.5A0 ~ 0.75A
18W 18W18W
120mVp-p 200mVp-p150mVp-p
±3.0%
±1.0%
±2.0%
1500ms, 30ms / 230VAC
47 ~ 63Hz
77% 82% 83%
0.3A/230VAC
0.25mA / 240VAC
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
± ℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
5. Suitable for indoor use or outdoor use without direct sunlight exposure.
6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
18W Single Output Switching Power Supply
180-264VAC input only
Fully encapsulated with IP67 level (Note.5)
Protections:Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Class power unit, no FG
Pass LPS
100% full load burn-in test
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)
High reliability / Low cost
2 years warranty
LPH-18 s e r i e s
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
File Name: LPH-18-SPEC 2017-11-03
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
Above 105% rated output power
HOLD UP TIME (Typ.) 50ms/230VAC at full load
13.8~ 16.2V 27.6~ 32.4V 41.4 ~ 48.6V
Protection type : Shut off o/p voltage, clamping by zener diode
140*30*22(L*W*H)
COLD START 50A(twidth=155 s measured at 50% Ipeak) at 230VACμ
Hiccup mode, recovers automatically after temperature goes down
TUV EN60950-1, IP67 approved; design refer to UL1310 Class 2,CAN/CSA No. 223-M91
1200.6K hrs min. MIL-HDBK-217F (25 )
0.175Kg; 70pcs/13.3Kgs/0.71CUFT
Features :
IP67
LPS
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
180 ~ 264VAC 254 ~ 370VDC
-30~ +70 (Refer to "Derating Curve")
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria AEMC IMMUNITY
EMC EMISSION


Produkt Specifikationer

Mærke: Monacor
Kategori: Skifte
Model: PSL-18/24

Har du brug for hjælp?

Hvis du har brug for hjælp til Monacor PSL-18/24 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Skifte Monacor Manualer

Skifte Manualer

Nyeste Skifte Manualer

Netgear

Netgear GS110TPP Manual

15 Oktober 2024
Lancom

Lancom CS-8132F Manual

7 Oktober 2024
Lancom

Lancom YS-7154CF Manual

7 Oktober 2024
Perel

Perel E305W3-G Manual

5 Oktober 2024
Tork

Tork SS720A Manual

5 Oktober 2024
Black Box

Black Box ACX300-R Manual

4 Oktober 2024