Moxa NPort 5650-8 Manual
Læs nedenfor 📖 manual på dansk for Moxa NPort 5650-8 (2 sider) i kategorien Server. Denne guide var nyttig for 25 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
– – – – – – 1 2 3
P/N: 1802056000211
NPort 5600 Series Quick
Installation Guide
Third Edition, November 2010
1. Overview
Welcome to the Moxa NPort 5600 Series. The NPort 5610-8/16
have 8 or 16 RS 232 ports, the NPort 5630 8/16 have 8 or 16 - -
RS-422/485 ports, and the NPort 5650-8/16 have 8 or 16
RS-232/422/485 ports.
2. Package Checklist
The NPort 5600 package should contain the following items:
• 1 8- 6-port or 1 port serial device server
• NPort Documentation & Software CD
• NPort 5600 Quick Installation Guide
Optional Accessories:
• CBL- - 8-RJ45M9 150: pin RJ45 to DB9 male cable, 150 cm
• CBL- - 8- RJ45F9 150: pin RJ45 to DB9 female cable, 150 cm
• CBL- - 8-RJ45M25 150: pin RJ45 to DB25 male cable, 150 cm
• CBL- - 8-RJ45F25 150: pin RJ45 to DB25 female cable, 150 cm
Notify your sales representative if any of the above items is
missing or damaged.
3. Hardware Introduction
The NPort 5600 Series has includes the following models: NPort
5610-8, NPort 5610-16, NPort 5610-8-48V, NPort 5610- -16 48V,
NPort 5630 8, NPort 5630- -16, NPort 5650 NPort 5650-8, -8- T,
NPort 5650- 16, NPort 5650 NPort 5650- - 16 T, -8-M-SC, NPort
5650 16- -M-SC, NPort 5650 and NPort 5650-8-S-SC, -16-S- SC.
NOTE
The wide temperature model does not support LCM display
panel
s or push bu s ttons. All of the LCM description below
apply only to s. standard temperature model
The front and rear panels are shown below:
Front panel of the NPort 5600 Series
Rear panel of the NPort 5610/5630/5650 (AC Power)
Rear panel of the NPort 5650 (Fiber Model)
Rear panel of the NPort 5610 (DC Power)
Front panel of the NPort 5650- T Series
Reset Button—press the Reset button continuously for 5 sec to
load factory defaults: Use a pointed object to press the reset
button. Release the button after the Ready LED stops blinking.
LED Indicators on the Front Panel—the front panels of the
NPort 5600 have several LED indicators, as described in the
following table.
Name
Color
Function
Ready
Off
Power is off, or power error condition exists.
Red
Steady on: Power is on and the NPort is
booting up.
Blinking: Indicates an IP conflict, or DHCP or
BOOTP server did not respond properly.
Green
Steady on: Power is on and the NPort is
functioning normally.
Blinking:
The NPort has been located by NPort
Administrator’s Location function.
1- 16
Orange
Serial port is receiving data.
Green
Serial port is transmitting data.
Off
No data is being transmitted or received
through the serial port.
LCM Display Panel—If the NPort is working properly, the LCM
panel will display a green color. The red Ready LED will also light
up, indicating that the NPort is receiving power. After the red
Ready LED turns green, you will see a display similar to:
N
P
5
6
1
0
-
1
6
3
8
1
9
2
.
1
6
8
.
1
2
7
.
2
5
4
This is where
• NP5610- 16 is the NPort’s name
• 38 is the NPort’s serial number
• 192.168.127.254 is the NPort’s IP address
LCM Panel Operation—There are four buttons on the NPort
5600’s front panel. These buttons are used to operate the server’s
LCM panel. Going from left to right, the buttons are:
Button
Action
MENU
Activates the main menu, or returns to a lower level.
︿
Scrolls up through a list of items shown on the LCM
panel’s second line.
﹀
Scrolls down through a list of items shown on the LCM
panel’s second line.
SEL Selects the option listed on the LCM panel’s second
line.
Detailed LCM Panel Operating instructions can be found on the
CD-ROM in the NPort 5600 Series User’s Manual.
Link Indicator on the rear panel of the NPort 5650 fiber
model—the rear panels of the NPort 5650 have a link indicator, as
described in the following table.
LED Name
LED Color
LED Function
Link
Off
Fiber disconnected.
Green
Fiber connected; data not transmitting.
Blinking
Fiber connected; data is transmitting.
4. Hardware Installation
STEP 1: After removing the NPort 5600 from the box, the first
thing you should do is attach the power adaptor.
STEP 2: Connecting the Power.
AC: Connect the NPort 5600’s 240 VAC power cord to the AC 1 -00
connector. T he “Ready” LED will show a solid red color until the
system is ready, at which time it will change to a green color.
DC: Connect the NPort 5610- -16/8 48V’s power cord to the DC
connector, and then follow the steps given below:
Loosen the screws on the V+ and V- terminals of
the NPort 5610-8/16- 48V’s terminal block.
Connect the power cord’s 48 VDC or - 48 VDC wire
to the terminal block’s V+ terminal, and the power
cord’s DC Power Ground wire to the terminal block’s V- terminal,
and then tighten the terminal block screws. (Note: The NPort
5610 8/16- - -48V can still operate even if the 48V/ 48V and DC
Power Ground are reversed.)
The “Ready” LED will show a solid red color until the system is
ready, at which time it will change to a green color.
Grounding the NPort 5610- - 8/16 48V:
Grounding and wire routing help limit the effects of
noise due to electromagnetic interference (EMI).
Run the ground connection from the ground
screw to the grounding surface prior to
connecting devices. The Shielded Ground
(sometimes called Protected Ground) contact is
the second contact from the right of the 5- pin power terminal block
connector located on the rear panel of the NPort 5610- -8/16 48V.
Connect the SG wire to the Earth ground.
STEP 3: Connect the NPort 5600 to a network. Use a standard
straight-through Ethernet cable to connect to a h sub or witch.
When setting up or testing the NPort 5600, you might find it
convenient to connect directly to your computer’s Ethernet port. In
this case, use a cross-over Ethernet cable.
Produkt Specifikationer
Mærke: | Moxa |
Kategori: | Server |
Model: | NPort 5650-8 |
Vægt: | 3360 g |
Opbevaringstemperatur (T-T): | -40 - 85 °C |
Relativ luftfugtighed ved drift (H-H): | 5 - 95 % |
Ethernet LAN-porte (RJ-45): | 1 |
Driftstemperatur (T-T): | 0 - 55 °C |
Ethernet LAN-datahastigheder: | 10, 100 Mbit/s |
Certificering: | CE, FCC, EN 55022 Class A, FCC Part 15 Subpart B Class A, \r\nEN 60601-1-2 Class B, EN 55011 |
Understøttede netværksprotokoller: | ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, HTTP, SMTP, SNTP, ARP, PPP, RTelnet, RFC2217 |
Indgangsspænding: | 100 - 240 V |
Kompatible operativsystemer: | Windows 98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8 x86/x64, Windows 2012 X64\r\n\r\nSCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i\r\n\r\nLinux kernel 2.4.x, 2.6.x, 3.x |
Isolering: | 1.5 kV |
Flowkontrol support: | Ja |
Administrationsprotokoller: | SNMP V1 |
Seriel grænsefladetype: | RS-232/422/485 |
Antal serielle porte: | 8 |
Baud hastighed: | 921.6 Kbit/s |
RS-232 signaler: | CTS, DCD, DSR, DTR, GND, RTS |
RS-422 signaler: | GND, RxD+, RxD-, TxD+, TxD- |
RS-485 signaler: | Data+, Data-, GND |
Sikkerhed: | UL 60950-1, EN 60950-1 |
Link/Act LED: | Ja |
Har du brug for hjælp?
Hvis du har brug for hjælp til Moxa NPort 5650-8 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Server Moxa Manualer
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
Server Manualer
- Server QNAP
- Server Bosch
- Server Acer
- Server Sony
- Server HP
- Server D-Link
- Server Asus
- Server Gigabyte
- Server Toshiba
- Server Lenovo
- Server Abus
- Server Planet
- Server Black Box
- Server TRENDnet
- Server Buffalo
- Server Medion
- Server Linksys
- Server Megasat
- Server Cisco
- Server Seagate
- Server Netgear
- Server Tripp Lite
- Server Western Digital
- Server Technics
- Server Digitus
- Server Dell
- Server Fujitsu
- Server MSI
- Server NEC
- Server APC
- Server LevelOne
- Server FLIR
- Server ZyXEL
- Server Eaton
- Server ELAC
- Server Synology
- Server Hikvision
- Server Monacor
- Server AVerMedia
- Server Asustor
- Server Kramer
- Server Hanwha
- Server LaCie
- Server Naim
- Server Fantec
- Server Provision-ISR
- Server Quantum
- Server Axis
- Server ACTi
- Server Digi
- Server ATen
- Server Teo
- Server Vimar
- Server Smart-AVI
- Server Intel
- Server Supermicro
- Server StarTech.com
- Server Conceptronic
- Server Rocstor
- Server IStarUSA
- Server Blackmagic Design
- Server Lindy
- Server Veritas
- Server Promise Technology
- Server Sitecom
- Server HGST
- Server AMX
- Server Intellinet
- Server Iomega
- Server Silverstone
- Server Geovision
- Server Ernitec
- Server KanexPro
- Server Gefen
- Server C2G
- Server Allnet
- Server Maxdata
- Server Matrox
- Server Valcom
- Server Freecom
- Server Revox
- Server G-Technology
- Server Areca
- Server SEH
- Server Ibm
- Server Sonnet
- Server TAIDEN
- Server SIIG
- Server Advantech
- Server Mobotix
- Server Extron
- Server Avocent
- Server Silex
- Server In Win
- Server Sun
- Server Atlona
- Server MvixUSA
- Server Dual Bay
- Server Raidsonic
- Server EMC
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Mr. Signal
- Server Atlantis Land
- Server Lantronix
- Server NETSCOUT
- Server Origin Storage
- Server IMC Networks
Nyeste Server Manualer
21 December 2024
18 December 2024
18 December 2024
15 December 2024
13 December 2024
11 December 2024
9 December 2024
8 December 2024
8 December 2024
8 December 2024