Installation Guide
Overview
The following table provides an overview of the power supply units (PSUs) for
managed switches and the models in which they are supported.
PSU Model Used in Switch
Model
APS150W M4300-28G
M4300-52G
APS250W M4300-8X8F
M4300-12X12F
M4300-24X24F
APS299W M4300-16X
APS550W M4300-28G-POE+
M4300-52G-POE+
APS600W M4300-96X
M4300-16X
APS750W M4500-32C
M4500-48XF8C
APS1000W M4300-28G-POE+
M4300-52G-POE+
M6100-3S
RPS4000v2
APS1200W M4300-96X
Install an additional power supply unit
In models with more than one power supply bay, you can install an additional
PSU.
1. Pull out the cover plate from the power module bay in which you want to
insert the additional PSU.
AC OK LED. All PSUs provide one AC OK
LED. During normal operation, this LED
lights green to indicate that the PSU is
receiving power.
DC OK LED. Model APS150W also provides
one DC OK LED. During normal operation,
this LED lights green to indicate that the DC
outputs are within regulation limits.
NETGEAR Power Supply Unit
for Managed Switches
APS150W, APS250W, APS299W, APS550W, APS600W,
APS750W, APS1000W, and APS1200W
Package contents
Power supply unit
Power cord (varies by region)
Installation guide
2. Insert the additional PSU into the power module bay, and gently push the
PSU into the bay.
CAUTION: When inserting the PSU, do not use unnecessary force. Doing so
can damage the connectors on the back of the PSU and on the midplane.
3. Connect the end of the power cord to the power receptacle on the PSU.
4. Plug the AC power cord into a power source such as a wall socket or power
strip.
When you apply power, the AC OK LED on the PSU lights. The LED on the
switch for the power supply bay also lights. If these LEDs do not light, make
sure that the power cord is plugged in and that the power source is good.
Replace a power supply unit
In models with more than one PSU, the PSUs are hot-pluggable.
1. If your switch functions with a single PSU only, disconnect the power cord
from the PSU and let the switch power down.
If your switch functions with more than one PSU, you do not need to power
down the switch and you can perform a hot swap.
2. Remove the PSU from the power module bay by moving the orange release
latch to the left and pulling the extraction handle.
3. Insert the replacement PSU into the power module bay, and gently push the
PSU into the bay until the latch locks.
CAUTION: When inserting the PSU, do not use unnecessary force. Doing so
can damage the connectors on the back of the PSU and on the midplane.
4. Connect the end of the power cord to the power receptacle on the PSU.


Produkt Specifikationer

Mærke: Netgear
Kategori: Ikke kategoriseret
Model: APS250W

Har du brug for hjælp?

Hvis du har brug for hjælp til Netgear APS250W stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Netgear Manualer

Netgear

Netgear JGS516 Manual

4 Oktober 2024
Netgear

Netgear GS108Ev4 Manual

30 September 2024
Netgear

Netgear Orbi RBE972SB Manual

26 September 2024
Netgear

Netgear Orbi RBK652S Manual

24 September 2024
Netgear

Netgear Nighthawk MS90 Manual

24 September 2024
Netgear

Netgear ProSafe AX745 Manual

22 September 2024
Netgear

Netgear ANT2409v2 Manual

22 September 2024
Netgear

Netgear FS517TS Manual

15 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024