SAFETY INFORMATION
1. Please read these instructions carefully.
2. Keep all information and instructions in a safe place.
3. Follow the instructions.
4. Observe all safety warnings. Never remove safety warnings or other information from the equipment.
5. Use the equipment only in the intended manner and for the intended purpose.
6. Use only sufficiently stable and compatible stands and/or mounts (for fixed installations). Make cer-
tain that wall mounts are properly installed and secured. Make certain that the equipment is installed
securely and cannot fall down.
7. During installation, observe the applicable safety regulations for your country.
8. Never install and operate the equipment near radiators, heat registers, ovens or other sources of heat.
Make certain that the equipment is always installed so that is cooled sufficiently and cannot overheat.
9. Never place sources of ignition, e.g., burning candles, on the equipment.
10. Ventilation slits must not be blocked.
11. Do not use this equipment in the immediate vicinity of water (does not apply to special outdoor
equipment - in this case, observe the special instructions noted below. Do not expose this equipment
to flammable materials, fluids or gases.
12. Make certain that dripping or splashed water cannot enter the equipment. Do not place containers
filled with liquids, such as vases or drinking vessels, on the equipment.
13. Make certain that objects cannot fall into the device.
14. Use this equipment only with the accessories recommended and intended by the manufacturer.
15. Open the device for changing the battery, do not modify this equipment.
16. After connecting the equipment, check all cables in order to prevent damage or accidents, e.g., due
to tripping hazards.
17. During transport, make certain that the equipment cannot fall down and possibly cause property
damage and personal injuries.
18. If your equipment is no longer functioning properly, if fluids or objects have gotten inside the equip-
ment or if it has been damaged in another way, switch it off immediately and unplug it from the
mains outlet (if it is a powered device). This equipment may only be repaired by authorized, qualified
personnel.
19. Clean the equipment using a dry cloth.
20. Comply with all applicable disposal laws in your country. During disposal of packaging, please sep-
arate plastic and paper/cardboard.
21. Plastic bags must be kept out of reach of children.
22. If the equipment has been exposed to strong fluctuations in temperature (for example, after trans-
port), do not switch it on immediately. Moisture and condensation could damage the equipment. Do
not switch on the equipment until it has reached room temperature.
23. Do not step on the power cord. Make certain that the power cable does not become kinked, especially
at the mains outlet and/or power adapter and the equipment connector.
24. When connecting the equipment, make certain that the power cord or power adapter is always freely
accessible. Always disconnect the equipment from the power supply if the equipment is not in use
or if you want to clean the equipment. Always unplug the power cord and power adapter from the
power outlet at the plug or adapter and not by pulling on the cord. Never touch the power cord and
power adapter with wet hands.
25. To disconnect the equipment from the power mains completely, unplug the power cord or power
adapter from the power outlet.
26. Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike
or before extended periods of disuse.
CAUT ION:
CAU TIO N
RIS K OF SELE CTRIC HOCK
DO N O NOT P E
There are no user serviceable parts inside. Have repairs carried out only by qualified service personnel.
CAUT ION – HIGH VOLUME LEVELS WITH AUDIO PRODUCTS!
This equipment is intended for professional use. Therefore, commercial use of this equipment is subject
to the respectively applicable national accident prevention rules and regulations. As a manufacturer, Adam
Hall is obligated to notify you formally about the existence of potential health risks. Hearing damage due to
high volume and prolonged exposure: When in use, this product is capable of producing high sound-pres-
sure levels (SPL) that can lead to irreversible hearing damage in performers, employees, and audience
members. For this reason, avoid prolonged exposure to volumes in excess of 90 dB.
MANUFACTURER’S WARRANTY & LIMITATION OF LIABILITY
You can find our current warranty conditions and limitation of liability at: http://www.adamhall.com/media/
shop/downloads/documents/manufacturersdeclarations.pdf
To request warranty service for a product, please contact Adam Hall GmbH, Daimler Straße 9, 61267 Neu
Anspach / Email Info@adamhall.com / 49 (0) 6081 / 9419-0
PROPER DISPOSAL OF THIS PRODUCT
(WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT)
(Valid in the European Union and other European countries with waste separation)
This symbol on the product, or the documents accompanying the product, indicates that this appliance
may not be treated as household waste. This is to avoid environmental damage or personal injury due
to uncontrolled waste disposal. Please dispose of this product separately from other waste and have it
recycled to promote sustainable economic activity.
SCOPE OF APPLICATION
When connecting mains-operated devices with a protective contact socket to each other using shielded
cables, ground loops can very easily occur through the double earthing. Such a situation typically arises
when connecting the computer’s sound card to your Hi-Fi system.
The PLI 03 isolation transformer from Palmer provides the perfect solution. Two high quality audio
transformers provide galvanic isolation, i.e. by separating the grounding at different ground potentials,
no flow equalisation current occurs, which is responsible for the familiar disturbing hum. Since high
frequency clock signals in computers can also cause problems on analogue audio grounding, the PLI 03
often removes such squeaks or sputtering noises.
The PLI03 features a ground lift switch. For most applications the switch should be set to “Lift”. In some
situations however - for example when connecting battery powered devices - a lacking ground can
lead to noise. In this case, set the switch to ground - this will ground the right (red) channel. Keep this in
mind when you are only using one channel on the PLI03 - be sure to use the right (red) channel.
The device is designed for stereo. Connect the analogue audio outputs right/left of your sound card with
the two RCA Sockets of the PLI 03, which are labelled as inputs. The output sockets must be connected
to the Hi-Fi system. Suitable inputs on the Hi-Fi system are e.g. the AUX or TAPE inputs. Use only
shielded audio cables.
The housing of the PLI 03 consists of an aluminium alloy that provides extra protection against high
frequency radiation. However, immunity against low frequency magnetic fields is less pronounced.
Therefore, you should avoid setting up the PLI 03 in the immediate vicinity of strongly emitting power
transformers.
The PLI 03 has been specially optimised for the level and impedance of sound cards. The data below
was established with a source impedance of 6000 ohms, which is typical for sound cards. Of course,
the PLI 03 can be used for the galvanic isolation of other audio components.
TECHNICAL SPECIFICATIONS
Product Type: line isolator
Type: passive
Number of Channels: 2
Number of Inputs: 2
Input Connections: 2 x RCA
Input Type: unbalanced
Input Impedance: 10 k Ohm(s)
Max. Input Level: + 6 dBU
Outputs: 2
Output Connections: RCA
Output Type: unbalanced
Output Impedance: 10 k Ohm(s)
Max. Output Levels: + 6 dB
Controls: Ground lift switch
Transformer-balanced: transformer isolated
Translation Ratio (Ratio): 1:1
Frequency response: 20 - 20,000 Hz
Housing Material: sheet steel
Housing Surface: powder coated
Width: 145 mm
Depth: 65 mm
Height: 45 mm
Weight: 0.58 kg
© Palmer Musical Instruments, Adam Hall GmbH, D-61267 Neu-Anspach, Daimlerstr. 9, Germany TEL: ++49 (0)6081 94190
FAX: ++49 (0)6081 43280 WEB: www.adamhall.com, www.palmer-germany.com EMAIL: info@palmer-germany.com
PLI- LINE ISOLATION BOX – 2 CHANNEL03


Produkt Specifikationer

Mærke: Palmer
Kategori: Ikke kategoriseret
Model: PLI-03

Har du brug for hjælp?

Hvis du har brug for hjælp til Palmer PLI-03 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Palmer Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer