Panasonic CU-E12PFE Manual


Læs nedenfor 📖 manual på dansk for Panasonic CU-E12PFE (80 sider) i kategorien Aircondition. Denne guide var nyttig for 19 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/80
F569015
Operating Instructions
Air Conditioner
Operating Instructions
Air Conditioner 2-9
Bedienungsanleitung
Klimagerät 10-17
Handleiding
Airconditioner 18-25
Istruzioni di funzionamento
Condizionatore d’aria 26-33
Οδηγίες λειτουργίας
Κλιματιστικό 34-41
Comment utiliser l’appareil
Climatiseur 42-49
Instrucciones de funcionamiento
Climatizador de aire
50-57
Instruções de funcionamento
Aparelho de ar condicionado 58-65
Инструкции работа за
Климатик 66-73
Български λληνικάPortuguês Español Français E Italiano Nederlands Deutsch English
Model No.
Indoor Unit
CS-E9GFEW
CS-E9GFEW-2
CS-E12GFEW
CS-E12GFEW-2
CS-E18GFEW
Outdoor Unit
Single Split Multi Split
CU-E9PFE
CU-E12PFE
CU-E18PFE
CU-2E15PBE
CU-2E18PBE
CU-3E18PBE
CU-4E23PBE
CU-4E27PBE
CU-5E34PBE
Multi air conditioner system
Multi air conditioner systems save space by
letting you connect multiple indoor units to a
single outdoor unit.
For complete product features, please refer
catalogue.
Indoor units
It is possible to operate the indoor units
individually or simultaneously. The priority
of operation is placed on the rst unit that
turned on.
During operation, HEAT and COOL modes
cannot activate at the same time for different
indoor units.
The power indicator blinks to indicate the
indoor unit is standing by for a different
operation mode.
Indoor units
Outdoor unit
( CU-2E15PBE, CU-2E18PBE, CU-3E18PBE,
CU-4E23PBE, CU-4E27PBE, CU-5E34PBE)
Operation conditions
Use this air conditioner under the following temperature range.
DBT: Dry bulb temperature / WBT: Wet bulb temperature
Single split outdoor unit
CU-E9PFE, CU-E12PFE, CU-E18PFE
Indoor Outdoor
DBT WBT DBT WBT
COOL Max. 32 23 43 26
Min. 16 11 16 11
HEAT Max. 30 - 24 18
Min. 16 - -15 -6
°C (temperature)
Multi split outdoor unit
CU-2E15PBE, CU-2E18PBE,
CU-3E18PBE, CU-4E23PBE,
CU-4E27PBE, CU-5E34PBE
Indoor Outdoor
DBT WBT DBT WBT
COOL Max. 32 23 46 26
Min. 16 11 -10 -
HEAT Max. 30 - 24 18
Min. 16 - -15 -16
°C (temperature)
Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
2
5
English
To prevent overheating, re or electric shock:
Do not share the same power outlet with
other equipment.
Do not operate with wet hands.
Do not over bend the power supply cord.
If the supply cord is damaged, it must be
replaced by the manufacturer, service agent
or similarly quali ed persons in order to avoid
a hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or re.
Stop using the product if any abnormality/
failure occurs and disconnect the power plug
or turn off the power switch and breaker.
(Risk of smoke/ re/electric shock) Examples
of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the unit is
observed.
Water leaks from the indoor unit.
Power cord or plug becomes abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately even if it
is switched on for operation.
The fan does not stop even if the operation
is stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or re.
Prevent electric shock by switching off the
power supply:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with water,
benzine, thinner or scouring powder to avoid
damage or corrosion at the unit.
Do not use for preservation of precise
equipment, food, animals, plants, artwork
or other objects. This may cause quality
deterioration, etc.
Do not use any combustible equipment
in front of the air ow outlet to avoid re
propagation.
Do not expose plants or pet directly to air ow
to avoid injury, etc.
Do not touch the sharp aluminium
n, sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the oor. After waxing, aerate the room
properly before operating the unit.
Do not install the unit in oily and smoky areas
to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose
to avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade
the insulation. This may cause an electric
shock.
Do not open window or door for long time
during COOL/DRY mode operation.
Prevent water leakage by ensuring drainage
pipe is:
- Connected properly,
- Kept clear of gutters and containers, or
- Not immersed in water
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to
prevent the unit from falling down.
Remote control
Do not use rechargeable (Ni-Cd) batteries. It
may damage the remote control.
To prevent malfunction or damage of the
remote control:
Remove the batteries if the unit is not going
to be used for a long period of time.
New batteries of the same type must be
inserted following the polarity stated.
Safety precautions


Produkt Specifikationer

Mærke: Panasonic
Kategori: Aircondition
Model: CU-E12PFE

Har du brug for hjælp?

Hvis du har brug for hjælp til Panasonic CU-E12PFE stil et spørgsmål nedenfor, og andre brugere vil svare dig




Aircondition Panasonic Manualer

Aircondition Manualer

Nyeste Aircondition Manualer

Daitsu

Daitsu AUD-30K-DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 36K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 48K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 60TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 42K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 48TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 36TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 18K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 24K DB Manual

28 Februar 2025