INSTRUCTION
MANUAL
Amplier Built-in Type Threaded Miniature Photoelectric Sensor
EX-30 Series
MJEC-EX30 No.0054-69V
Thank you very much for purchasing Panasonic products.
Read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
Please refer to “users manual on our web site (http://
panasonic.net/id/pidsx/global)
for more details
(specication, and operation etc.)
Access method is “Download” → “Model no.”
If you could not visit our web site, contact our sales
ofce near your sight.
WARNING
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI or
IEC etc., for personnel protection applicable in each region or country.
1
INTENDED PRODUCTS FOR CE MARKING
Refer “our web site (http://panasonic.net/id/pidsx/global)”
for the intended products.The models listed under SPEC-
IFICATIONS” come with CE Marking. As for all other mod-
els, please contact our ofce.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
2PART DESCRIPTION
Notes: 1) Not incorporated on the thru-beam type sensor emitter.
2) Incorporated on EX-33□. Not incorporated on the receiver
for EX-31□, and EX-32□.
3) Incorporated on the emitter for EX-33□, and EX-32□. Not
incorporated on
EX-31 .
3MOUNTING
Mount the sensor on a mounting plate 3mm
or less thick and Use the enclosed nut and
toothed lock washer for mounting.
When the nut is tightened, hold the the sensor
with hand or a spanner etc. and the tightening
torque should be 0.6Nm or less. (EX-32
:
1N•m or less) Do not tighten the sensor itself.
4WIRING DIAGRAMS
Note:
The thru-beam type sensor emitter does not incorporate the output.
Mounting plate
(3mm or less thick)
Operation mode switch (Note 2)
L: Light-ON
D: Dark-ON
Sensitivity adjuster (Note 3)
Sensing range be-comes
longer when turned clockwise
Operation indicator (Orange) (Note 1)
Lights up when the sensing
output is ON
Stability indicator (Green) (Note 1)
Lights up under the stable light
condition or the stable dark condition
(Brown) +V
(Black)
Output (Note)
(Blue) 0V
Load
12 to 24V DC
±10%
PNP output type
(Brown) +V
(Black)
Output (Note)
(Blue) 0V
Load
12 to 24V DC
±10%
NPN output type
- -
5SENSITIVITY ADJUSTMENT
Step
1.
Turn the sensitivity adjuster fully counterclockwise
to the minimum sensitivity position, MIN.
2.
In the light received condition, turn the sensitivity
adjuster slowly clockwise and conrm the point A
where the sensor enters the “Light” state operation.
3.
In the dark condition, turn the sensitivity
adjuster further clockwise until the sensor en-
ters the “Light” state operation and then bring
it back to conrm point B where the sensor
just returns to the “Dark” state operation.
If the sensor does not enter the “Light state
operation even when the sensitivity adjuster is
turned fully clockwise, the position is point B.
4. The position at the middle of points A and
B is the optimum sensing position.
6CAUTIONS
This product has been developed / produced for industrial use only.
The thin cable 0.1mm2 is used for this product. Thus, take care that
if the cable is pulled with excessive force, it may cause cable break.
Extension up to total 50m (emitter and receiver each for thru-
beam type), or less, is possible with 0.3mm
2, or more, cable.
Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
Make sure to carry out wiring in the power supply OFF condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regu-
lator, ensure that the frame ground (F.G.) terminal of the
power supply is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the
frame ground (F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
Do not use during the initial transient time (50ms) after
the power supply is switched ON.
Take care that the sensor is not directly exposed to uorescent
lamp from a rapid-starter lamp, a high frequency lighting de-
vice or sunlight etc., as it may affect the sensing performance.
This sensor is suitable for indoor use only.
Do not use this sensor in places having excessive vapor, dust,
etc., or where it may come in contact with corrosive gas, etc.
Take care that the sensor does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid, or alkaline.
This sensor cannot be used in an environment contain-
ing inammable or explosive gases.
Never disassemble or modify the sensor.
In case of using the sensor at a place where static electricity is generated,
use a metal mounting plate. Also, ensure to ground the mounting plate.
7RoHS DIRECTIVE
This equipment complies with RoHS (EC and Chinese directive).
Chinese RoHS indicates inclusion despite regulation value. (Refer Chinese part.)
A
B
A
B
A
Optimum position
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Ofce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
PRINTED IN JAPAN


Produkt Specifikationer

Mærke: Panasonic
Kategori: Ikke kategoriseret
Model: EX32APN

Har du brug for hjælp?

Hvis du har brug for hjælp til Panasonic EX32APN stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Panasonic Manualer

Panasonic

Panasonic KX-HN1003 Manual

25 November 2024
Panasonic

Panasonic MK-F511 Manual

25 November 2024
Panasonic

Panasonic NB-G200 Manual

24 November 2024
Panasonic

Panasonic AW-SF200Z Manual

8 November 2024
Panasonic

Panasonic AW-PS551PJ Manual

7 November 2024
Panasonic

Panasonic ER-CFC1 Manual

26 September 2024
Panasonic

Panasonic RP-SDW48GE1K Manual

14 September 2024
Panasonic

Panasonic C-D535AF Manual

5 September 2024
Panasonic

Panasonic ES-WM31 Manual

5 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

AOpen

AOpen DEX5950 Manual

26 November 2024
AOpen

AOpen WB5102 Manual

26 November 2024
AOpen

AOpen DE6100 Manual

26 November 2024
AOpen

AOpen DE5900 Manual

26 November 2024
AOpen

AOpen DE7000 Manual

26 November 2024
AOpen

AOpen DE7600 Manual

26 November 2024
AOpen

AOpen DES3200 Manual

26 November 2024
AOpen

AOpen DEN5128 Manual

26 November 2024
AOpen

AOpen DES4100 Manual

26 November 2024
AOpen

AOpen DEV7610 Manual

26 November 2024