PCE Instruments PCE-MO 1500 Manual
PCE Instruments
Måling
PCE-MO 1500
Læs nedenfor 📖 manual på dansk for PCE Instruments PCE-MO 1500 (2 sider) i kategorien Måling. Denne guide var nyttig for 23 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
User Manual
Megohmmeter
PCE-MO 1500
Safety Requirements & Safety Warnings:
This series of insulation resistance tester is designed and produced according to the safety
standard IEC1010. Strictly follow the safety standards of double insulation CAT III 1000V
CAT IV and pollution degree 2. To protect your safety, please read the manual before using
it.
Precautions:
Safety Symbol Description:
Caution! Refer to the user’s manual before using this meter. Double Insulation
Warning! Dangerous Voltage (Risk of electric shock).
Danger: To avoid serious or fatal damage that may be caused by certain states and wrong
operations.
Warning: indicates avoiding the risk of electric shock.
Caution: indicates avoiding damage to the instrument and making accurate measurements.
· Do not test in flammable locations, sparks may cause an explosion.
· Do not operate the instrument if the instrument surface is wet or if the operator's hands
are wet.
· When testing voltage, there is a possibility of personal injury due to accidental
short-circuit between metal parts and test leads.
· Do not exceed the maximum allowable range of the measuring range during measure-
ment.
· Do not open the battery cover during measurement.
· When performing insulation measurement, do not touch the line under test.
Warning
· If the instrument is abnormal, please stop using it. For example: Broken instrument or
exposed metal parts, please do not use it in this situation.
· When the test lead is inserted into the instrument interface and connected to the circuit
for testing, do not press the function button, but exit the measurement first, and then
change the test item. ·
Do not install substitute parts or make any unauthorized changes to the instrument.
· Do not replace the battery when the instrument is wet.
· Make sure all test leads are securely connected to the meter's test sockets.
· Make sure the instrument is turned off before opening the battery cover.
Caution:
· Before measuring, confirm that the function button is selected to the appropriate
position.
· After use, press and hold the “OFF” button to turn off the unit. If you do not use it
for a long time, please take out the battery and storage it.
·Do not storage for a long time in high temperature, humidity, places where condensation
may occur, or in direct sunlight.
· Please use a damp cloth or detergent to clean the instrument case, do not use abrasives
or solvents to wipe the instrument case and accessories.
· When the instrument is wet, please dry it before use or storage.
General:
Insulation resistance tester (or high voltage insulation meter) is a special instrument for
measuring insulation resistance. It is an ideal test instrument for measuring insulation
resistance of large transformers, transformers, generators, high-voltage motors, power
capacitors, power cables, arresters, etc.
· Automatic release voltage function.
· Suitable for measuring insulation resistance of various electrical equipment and
insulating materials such as transformers, motors, cables, switches, electrical appliances, etc.
It is suitable for the maintenance, repair, test and verification of various electrical
equipment.
· Rated output voltage variable
The rated output voltage can be switched by the function buttons "▲" "▼":
1000V switches between 50V, 100V, 250V, 500V, 1000V
2500V switches between 250V, 500V, 1000V,2000V, 2500V.
5000V switches between 500V, 1000V, 2500V, 5000V.
· High voltage indication
There is a red LED light in the machine indicating that there is high voltage output in the
instrument, there is a danger of electric shock, the operator should pay special attention to
safety.
· Low battery voltage indication " ".
· Battery-driven, easier to use.
· 2000 digits with bar graph display, easy to read the data.
Measuring range:
1000V: 0.1MΩ 20GΩ~
2500V: 1MΩ~200GΩ
5000V: 10M~200GΩ, automatic range conversion.
·Easy to operate and carry.
· Strong load capacity, <1.8mA output short-circuit current.
· Complete protection circuit, not afraid of voltage counterattack, output short
circuitprotection.
· It can measure AC/DC voltage 10V-600V, AC voltage frequency 40Hz ~ 70Hz.
· Dust-proof and moisture-proof structure, suitable for outdoor operation.
· Dimensions: 180X140X70 (mm)
· Weight: about 800g (including battery)
A. Technical Data
Working humidity conditions: 0°C~35°C, relative 75% or less, 2000 meters above sea
level
Output voltage: (output ±10% load >=1000M )Ω
Short circuit current: about less than 1.8mA;
Low battery indication: Display shows
Insulation resistance: >=500MΩ (1000V);
Withstand voltage: AC 2KV 50Hz 1 minute;
Working temperature and working humidity: temperature 0°C~40°C, relative humidity
85% or less;
Table 2. 2500V technical parameters
Output voltage: ±10%
250V/500V/1000V/2000V/2500V
B. Appearance
1. Insulation resistance measurement high voltage output jack L
2. Positive terminal of AC/DC voltage measurement
3. Voltage measurement input negative shielding end G (shielding end)
4. Insulation resistance measurement sampling jack E
Produkt Specifikationer
Mærke: | PCE Instruments |
Kategori: | Måling |
Model: | PCE-MO 1500 |
Har du brug for hjælp?
Hvis du har brug for hjælp til PCE Instruments PCE-MO 1500 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Måling PCE Instruments Manualer
6 December 2024
4 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
31 Oktober 2024
31 Oktober 2024
31 Oktober 2024
31 Oktober 2024
Måling Manualer
- Måling Bosch
- Måling SilverCrest
- Måling Hager
- Måling Owon
- Måling DeWalt
- Måling Extech
- Måling Silverline
- Måling IFM
- Måling Pioneer
- Måling Finder
- Måling Mitsubishi
- Måling Braun
- Måling Metrix
- Måling TFA
- Måling Garmin
- Måling Pyle
- Måling Güde
- Måling ABB
- Måling Hama
- Måling BENNING
- Måling Smartwares
- Måling Laserliner
- Måling Black And Decker
- Måling Trotec
- Måling Hilti
- Måling Soehnle
- Måling König
- Måling Powerfix
- Måling Flexa
- Måling Festo
- Måling Danfoss
- Måling Bresser
- Måling Alecto
- Måling Contec
- Måling VDO
- Måling Westfalia
- Måling Basetech
- Måling Voltcraft
- Måling Testboy
- Måling Velleman
- Måling FLIR
- Måling Perel
- Måling Vemer
- Måling ORNO
- Måling Amprobe
- Måling Fluke
- Måling Stabila
- Måling Ridgid
- Måling Sun Joe
- Måling ADE
- Måling Projecta
- Måling Hazet
- Måling Park Tool
- Måling Pantone
- Måling Testo
- Måling GW Instek
- Måling Brandson
- Måling Etymotic
- Måling Cablexpert
- Måling Kopp
- Måling Steinberg
- Måling Eltako
- Måling Eastron
- Måling Vimar
- Måling Klein Tools
- Måling PeakTech
- Måling Uni-T
- Måling Joy-It
- Måling Kübler
- Måling Kern
- Måling Chauvin Arnoux
- Måling Megger
- Måling Peak
- Måling TDE Instruments
- Måling ClimeMET
- Måling Adwa
- Måling Gossen Metrawatt
- Måling Siglent
- Måling Hikmicro
- Måling PCE
- Måling Pico
- Måling Sonel
- Måling Murideo
- Måling Workzone
- Måling Sauter
- Måling Sikkens
- Måling X4-LIFE
- Måling Tru Components
- Måling Ebro
- Måling Berger & Schröter
- Måling Histor
- Måling Sanwa
- Måling MSW
- Måling Camille Bauer
- Måling Crelando
- Måling CSL
- Måling Stamos
- Måling Stelzner
- Måling Dranetz
- Måling Clare
- Måling Brookhuis
- Måling Crowcon
- Måling Intact
- Måling PQ Plus
- Måling DriveTest
- Måling Helvi
Nyeste Måling Manualer
16 December 2024
16 December 2024
15 December 2024
15 December 2024
15 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
13 December 2024