Side 1/8
Ph Sf Cpny r eac n s gurte
BATTERY INSTALLATION 4 X LR03 AAA ALKALINE
(SUPPLIED)
1. FIRST OPENING ON FACTORY DEFAULT CODE
Step 1 Press ‘C’ button
Step 2 Press factory code ‘ 1 2 3 4 5 6’
Step 3 Press ‘#’ button, a melodic tone will sound and the display
 conrmsOPEnd
Step 4 Turn Knob or Handle clockwise and open the door while the
tone is sounding
Caution
Ifanincorrectcodeisentered,Errorwillappearinthedisplaypanelanda
shortwarningtonewillsound.Ifanincorrectcodeisenteredvetimesthe
lockwillceasetooperateforveminutes,awarningtonewillsoundand
thedisplaywillindicatedELAY.
C > 1 > 2 > 3 > 4 > 5 > 6 > #
2. SETTING A NEW PERSONAL CODE.
Itisadvisabletosetanewcodewiththedooropenandtestthenewcode
before closing the door.
Step 1 Press ‘#’ button
Step2 EnterthePresentCode.
Step 3 Press ‘#’ button.
Step4 EnterNew4~16digitCode.
Step 5 Press ‘# button.
For Example:
If the present code is 1 2 3 4 5 6 and a new four digit code is decided as 4
2 4 2 press buttons as below.
# 1 2 3 4 5 6 # 4 2 4 2 #
EnTErdwillbeindicatedinthedisplayandashort3secondtonewill
soundtoconrmthechangeto4242
# > 1 2 3 4 5 6 > # > 4 2 4 2 > #
3. SETTING THE DUAL CONTROL FUNCTION WHERE
TWO OPERATORS WITH INDIVIDUAL PERSONAL CODES
ARE REQUIRED TO OPEN THE LOCK.
With the door in the open position set the second code.
Step 1 Press the “M” memory button recessed into the back
of the door.
Step 2 Press ‘2’ button
Step 3 Press ‘#’ button
Step4 Enter2ndPersonalcode
Step 5 Press ‘#’ button
EnTErdwillbeindicatedinthedisplayandashort3secondtonewill
sound,toconrmthe2ndcodeentry.
For Example:
If the present code is 4 2 4 2 and a second new four digit code is decided
as6789pressbuttonsasbelow.EnTErdwillappearinthedisplay
accompaniedbyashorttonetoconrmM2#6789#
M > 2 > # > 6 7 8 9 > #
4. TO ACTIVATE DUAL CONTROL
Step 1 Press the “M” memory button recessed into the back of the
door.
Step 2 Press ‘9’ button
Step 3 Press ‘#’ button
M > 9 > #
5. TO OPERATE WITH THE DUAL CONTROL FUNCTION
Step 1 Press C button dual will appear in the display.
Step2 Entertherstcode4242
Step3 Press‘#’button.ashort3secondtonewillsoundtoconrm
correct code
Step 4 Within 5 minutes enter the second code 6 7 8 9
Step5 Press‘#button.ashort3secondtonewillsoundtoconrm
correctcodeandOPEndwillappearinthedisplayandthelock
willbeopen.Eithercodecanbeenteredrstorsecond.
C > 4 2 4 2 > # > 6 7 8 9 > #
6. TO DEACTIVATE DUAL CONTROL
Step 1 Press the “M” memory button recessed into the back of the
door.
Step 2 Press ‘9’ button
Step3 Press‘#’buttonashort3secondtonewillsoundtoconrm
 deactivationandSinGLEwillappearinthedisplay.Thesecond
code will be automatically erased.
M > 9 > #
7. TO HIDE CODE IN THE DISPLAY AND TURNOFF
KEYPAD SOUND.
Activate Pressthe“M”memorybuttonrecessedintothebackofthe
 door,press7then#(HIdEappearsinthedisplay)
DeactivatePressthe“M”memorybuttonrecessedintothebackofthe
door, press 7 then #
M > 7 > #
8. TO HIDE CODE ENTRY IN A NUMBER SEQUENCE.
The code can be disguised by inserting random numbers either before,
after or both before and after, the personal code. This procedure is
designedtoincreasesecurityandtoconfuseapotentialobserver
attempting to memorise the code. This feature can be also be used
withhiddencodedisplayandsilentkeypadasat7above.
For Example
Personalcodeissetas4242Randomprexnumbers61Randomsux
numbers 91507
Step 1 Press C button
Step2 EnterCodeas61424291507
Step 3 Press ‘#’ button
ThedisplaywillconrmOPEnd
C > 61 4 2 4 2 91507 > #
9. ALARM SETTING
Activate Pressthe“M”memorybuttonrecessedintothebackofthe
 door,press8then#(ALErTappearsinthedisplay)M > 8 > #
Deactivate
Step 1 Press ‘C button
Step2 EnterPersonalCode
Step3 Press‘#’buttonashort3secondtonewillsoundtoconrm
 deactivationandOPEndwillappearinthedisplay.
C > Personal Code > #
10. BATTERY LIFE: 1 YEAR 3 TIMES A DAY.
BATTERY REPLACEMENT IS REQUIRED WHEN:
1. LObAttappearsindisplayaccompaniedbyashortonesecondwarn-
ing tone.
2. Correct code is entered but lock will not open.
3. Evenifbatteriesarecompletelyexhausted,thecodesarenotlost.
11. BATTERIES
4x1.5VAAAAlkalineBatteriesarerequiredtoactivatethelock.Used
batteries should not be disposed of with normal domestic waste. These
shouldbedisposedofatapprovedcollectionpoints.Youmay
alsoreturnusedbatteriestoyourRetailerattheirexpense
(whereapplicable).
V1/PBMAY2018
KeypadandLCDdisplaywindow
CButton
start button
#Button Batteryposition
under keypad
2. Press the keypad opening mark, to
release the retaining arm and swing the
keypad up and left, to open.
1.Removekeypad
retaining screw
Upper
part
Lower
part OpeningBatteryCompartment
OPERATING INSTRUCTIONS FOR DS2500E
& GUARANTEE REGISTRATION


Produkt Specifikationer

Mærke: Phoenix
Kategori: Vault
Model: DS2500

Har du brug for hjælp?

Hvis du har brug for hjælp til Phoenix DS2500 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vault Phoenix Manualer

Phoenix

Phoenix SS0721EP Manual

11 Januar 2025
Phoenix

Phoenix FS1512 Manual

14 Oktober 2024
Phoenix

Phoenix CB0102K Manual

14 Oktober 2024
Phoenix

Phoenix FS1911 Manual

14 Oktober 2024
Phoenix

Phoenix GS8017 Manual

14 Oktober 2024
Phoenix

Phoenix HS3554 Manual

5 Oktober 2024
Phoenix

Phoenix HS6076 Manual

5 Oktober 2024
Phoenix

Phoenix HS1055 Manual

17 September 2024
Phoenix

Phoenix HS6073 Manual

21 August 2024

Vault Manualer

Nyeste Vault Manualer

Olympia

Olympia GOsafe H20 Manual

11 Januar 2025
Kogan

Kogan KADSAFM16LA Manual

8 Januar 2025
MSW

MSW -FPS-02 Manual

31 December 2025
Sistec

Sistec TSF 1909 Manual

30 December 2025
Honeywell

Honeywell 5005P Manual

29 December 2024
Perel

Perel BG80052 Manual

14 December 2024