Planet IGS-500T Manual
Læs nedenfor 📖 manual på dansk for Planet IGS-500T (4 sider) i kategorien Bryter. Denne guide var nyttig for 23 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/4
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Thank you for purchasing PLANET compact industrial 5-port
10/100/1000T Gigabit Ethernet Switch, IGS-500T. In the following
section, the term means the “Industrial Gigabit Ethernet Switch”
IGS-500T.
Open the box of the Industrial Gigabit Ethernet Switch and carefully
unpack it. The box should contain the following items:
Industrial Gigabit Ethernet Switch x 1 User’s Manual x 1
Wall-mount Kit DIN-rail Kit
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original packing
material, and use them again to repack the product in case there is a
need to return it to us for repair.
3. Product Specications
Model IGS-500T
Hardware Specications
Copper Ports 5 x 10/100/1000BASET RJ45 TP auto-MDI/
MDI-X, auto negotiation
Connector
Removable 6-pin terminal block
Pin 1/2 for Power 1; Pin 3/4 for fault alarm; Pin
5/6 for Power 2
Alarm Provides one relay output for power failure
Alarm relay current carry ability: 1A@DC 24V
LED
3 x LED for system and power:
Green: DC Power 1
Green: DC Power 2
Red: Power Fault
2 x LED for each copper port
Green: 1000Mbps LNK/ACT
Orange:10/100Mbps LNK/ACT
ESD Protection 6KV
EFT Protection 6KV
Power Requirements
12~48V DC, redundant power with polarity
reverse protection function, 24V AC power
support
Power Consumption
/ Dissipation 3.6 watts/12.35BTU
Installation DIN-rail kit and wall-mount ear
Enclosure IP30 metal case
Dimensions
(W x D x H) 70 x 104 x 30 mm
Weight 252g
LED Denition:
LED Color Function
P1 Green Lights to indicate power input 1 has power.
P2 Green Lights to indicate power input 2 has power.
Fault Red Lights to indicate that power 1 or power 2 has
failed.
1000
LNK/ACT Green
Lights: Indicating the port is running at
1000Mbps speed and successfully established.
Blinks: Indicating that the switch is actively
sending or receiving data over that port.
100
LNK/ACT Orange
Lights: Indicating the port is running at
10/100Mbps speed and successfully established.
Blinks: Indicating that the switch is actively
sending or receiving data over that port.
Top View:
1 2 3 4 5 6
Figure 3: IGS-500T Top View
4.2 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial
Gigabit Ethernet Switch is used for two DC redundant power inputs.
Please follow the steps below to insert the power wire.
4. Hardware Introduction
4.1 Three-View Diagram
The three-view diagram of the Industrial Gigabit Ethernet Switch
consists of ve auto-sensing 10/100/1000BASE-T RJ45 port and one
removable 6-pin terminal block. The LED indicators are also located
on the front panel.
18.00
9.00
91.00
52.00 52.00
104.00
30.00
50.00
30.00
70.00
21.69
28.65
Dimensions ( unit = mm )
Side View Front View Side View
Top View Bottom View
Rear View
P1 P2 FAULT
1
2
3
4
5
1000
100
ACTLNK
ACTLNK
Figure 1: IGS-500T Three-View Diagram
2. Product Features
Physical Port
5-port 10/100/1000BASE-T RJ45 with auto-MDI/MDI-X function
Layer 2 Features
Complies with IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX,
IEEE 802.3ab 1000BASE-T Ethernet standard
Supports auto-negotiation and 10/100Mbps half/full duplex and
1000Mbps full duplex
Prevents packet loss with back pressure (half-duplex) and IEEE
802.3x pause frame ow control (full-duplex)
High-performance Store and Forward architecture, broadcast storm
control and runt/CRC ltering eliminate erroneous packets to opti-
mize the network bandwidth
Backplane (switching fabric): 10Gbps
Integrated address look-up engine, supporting 4K absolute MAC
addresses
9K jumbo packet size
Automatic address learning and address aging
CSMA/CD Protocol
Industial Case and Installation
IP30 metal case
DIN rail and wall-mount design
12 to 48V DC, redundant power with polarity reverse protect func-
tion and connective, removable terminal block for master and slave
power; 24V AC power support
Supports 6000 VDC Ethernet ESD protection
-40 to 75 degrees C operating temperature
Free fall, shock-proof and vibration-proof for industries
Switch Specications
Switch Processing
Scheme Store-and-Forward
Address Table 4K entries
Buffer Memory 1M bits on-chip buffer memory
Flow Control Back pressure for half duplex
IEEE 802.3x pause frame for full duplex
Switch Fabric 10Gbps
Throughput
(packet per second) 7.4Mpps@64bytes
Jumbo Frame 9K
Network Cables
10/100/1000BASE-T
Cat. 3, 4, 5, 5e, 6 UTP cable (max. 100 meters)
EIA/TIA-568 100-ohm STP (max. 100 meters)
Standards Conformance
Standards
Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab Gigabit Ethernet
IEEE 802.3x Full-Duplex Flow Control
IEEE 802.3az Energy Efcient Ethernet
IEEE 802.1p Class of Service
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC 60068-2-32 (free fall)
IEC 60068-2-27 (shock)
IEC 60068-2-6 (vibration)
Environment
Temperature Operating: -40~75 degrees C
Storage: -40~75 degrees C
Humidity Operating: 5~90%,
Storage: 5~90% (non-condensing)
Front View:
P1 P2 FAULT
1
2
3
4
5
1000
100
ACTLNK
ACTLNK
Figure 2: IGS-500T Front View
When performing any of the procedures like inserting the
wires or tightening the wire-clamp screws, make sure the
power is OFF to prevent from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1 and 2
for POWER 1, or contacts 5 and 6 for POWER 2.
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
Note
1. The wire gauge for the terminal block should be in the
range between 12 and 24 AWG.
2. The DC power input range is 12V ~ 48V DC and
supports 24V AC
3. Please just use one power input when using 24V AC.
Produkt Specifikationer
Mærke: | Planet |
Kategori: | Bryter |
Model: | IGS-500T |
Kode for international beskyttelse (IP): | IP30 |
Bredde: | 30 mm |
Dybde: | 70 mm |
Højde: | 104 mm |
Vægt: | 252 g |
Produktfarve: | Blå |
Opbevaringstemperatur (T-T): | -40 - 75 °C |
Relativ luftfugtighed ved drift (H-H): | 5 - 90 % |
Relativ luftfugtighed ved opbevaring (H-H): | 5 - 90 % |
Strømforbrug (typisk): | 3.6 W |
Driftstemperatur (T-T): | -40 - 75 °C |
Husmateriale: | Metal |
Certificering: | FCC Part 15 Class A, CE\nIEC 60068-2-32 (free fall)\nIEC 60068-2-27 (shock)\nIEC 60068-2-6 (vibration) |
Netværksstandarder: | IEEE 802.1p, IEEE 802.3, IEEE 802.3ab, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x |
LED-indikatorer: | Ja |
Kan monteres på væggen: | Ja |
Harmoniseret systemkode (HS): | 85176990 |
DC indgangsspænding: | 24 V |
Fuld duplex: | Ja |
Strøm over Ethernet (PoE): | Ingen |
Switch-type: | Ikke administreret |
10G understøttelse: | Ingen |
Auto MDI/MDI-X: | Ja |
Flowkontrol support: | Ja |
Basis omskiftning RJ-45 Ethernet porte, antal: | 5 |
Basis omskiftning RJ-45 Ethernet porttype: | Gigabit Ethernet (10/100/1000) |
Opbevar-og-frem: | Ja |
MAC adresselabel: | 4000 entries |
Switch kapacitet: | 10 Gbit/sek. |
Gennnemløb: | 7.4 Mpps |
Jumbo Frames support: | Ja |
Jumbo rammer: | 9000 |
Varmeafgivelse: | 12.35 BUT/t |
Gigabit Ethernet (kobber) porte, antal: | 5 |
MAC-adresse auto-indlæring understøttet: | Ja |
MAC-adresse auto-forældelse understøttet: | Ja |
DIN-skinne montering: | Ja |
Auto-forhandling: | Ja |
Pakke bufferlager: | 1 MB |
Redundant strømforsyning: | Ja |
Understøttede kabeltyper: | Cat3, Cat4, Cat5, Cat5e, Cat6 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Planet IGS-500T stil et spørgsmål nedenfor, og andre brugere vil svare dig
Bryter Planet Manualer
7 September 2024
5 September 2024
25 April 2024
23 August 2023
1 August 2023
23 Juli 2023
8 Juli 2023
5 Juli 2023
18 Marts 2023
2 December 2022
Bryter Manualer
- Bryter QNAP
- Bryter Bosch
- Bryter SilverCrest
- Bryter Panasonic
- Bryter Hager
- Bryter TP-Link
- Bryter Ei Electronics
- Bryter IFM
- Bryter Finder
- Bryter Behringer
- Bryter HP
- Bryter Sennheiser
- Bryter D-Link
- Bryter Asus
- Bryter Pyle
- Bryter One For All
- Bryter Yamaha
- Bryter Nedis
- Bryter Abus
- Bryter Hama
- Bryter Belkin
- Bryter Edimax
- Bryter Theben
- Bryter Black Box
- Bryter Wago
- Bryter DataVideo
- Bryter TRENDnet
- Bryter Smartwares
- Bryter Honeywell
- Bryter Quigg
- Bryter Buffalo
- Bryter Linksys
- Bryter Cisco
- Bryter Huawei
- Bryter König
- Bryter Elro
- Bryter Powerfix
- Bryter Netgear
- Bryter Totolink
- Bryter Triax
- Bryter Tripp Lite
- Bryter Mercury
- Bryter Goobay
- Bryter Digitus
- Bryter Alecto
- Bryter Techly
- Bryter Tork
- Bryter Schneider
- Bryter Marmitek
- Bryter APC
- Bryter Kathrein
- Bryter GlobalTronics
- Bryter Omnitronic
- Bryter LevelOne
- Bryter Perel
- Bryter Mercusys
- Bryter JUNG
- Bryter Vemer
- Bryter ZyXEL
- Bryter Tiptel
- Bryter Tenda
- Bryter Eaton
- Bryter Shimano
- Bryter Hikvision
- Bryter Monacor
- Bryter Paladin
- Bryter Brennenstuhl
- Bryter Ubiquiti Networks
- Bryter Cotech
- Bryter Aeon Labs
- Bryter Chamberlain
- Bryter GAO
- Bryter EnGenius
- Bryter AV:link
- Bryter Grandstream
- Bryter EVE
- Bryter Renkforce
- Bryter Mikrotik
- Bryter Kramer
- Bryter Kopp
- Bryter Merlin Gerin
- Bryter ATen
- Bryter Vimar
- Bryter Smart-AVI
- Bryter Doepke
- Bryter Crestron
- Bryter Russound
- Bryter Lancom
- Bryter Audac
- Bryter Homematic IP
- Bryter Intellinet
- Bryter Steren
- Bryter Intelix
- Bryter Equip
- Bryter RGBlink
- Bryter Profile
- Bryter Blustream
- Bryter Intermatic
- Bryter Sygonix
- Bryter PAC
- Bryter Extron
- Bryter PureLink
- Bryter Extreme Networks
- Bryter Cudy
- Bryter STI
Nyeste Bryter Manualer
16 September 2024
16 September 2024
7 September 2024
5 September 2024
21 August 2024
21 August 2024
14 August 2024
11 August 2024
11 August 2024
8 August 2024