Planet ISW-500T Manual


Læs nedenfor 📖 manual på dansk for Planet ISW-500T (4 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 7 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
- 1 - - 2 - - 3 - - 4 -
1. Package Contents
Thank you for purchasing PLANET industrial 5-/8-port 10/100TX
Compact Ethernet Switch, ISW-500T/800T. In the following section, the
term “Industrial Ethernet Switch” means the ISW-500T or ISW-800T.
Open the box of the Industrial Ethernet Switch and carefully unpack it.
The box should contain the following items:
Industrial Ethernet Switch x 1 User’s Manual x 1
DIN-rail Kit x 1 Wall-mount Kit x 1 RJ45 Dust Cap
ISW-500T x 5
ISW-800T x 8
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original packing
material, and use them again to repack the product in case there is a
need to return it to us for repair.
2.ProductSpecications
Product ISW-500T ISW-800T
Hardware Specications
Copper Ports 5 10/100BASE-TX RJ45
auto-MDI/MDI-X ports
8 10/100BASE-TX RJ45
auto-MDI/MDI-X ports
Switch Architecture Store-and-Forward
Switch Fabric 1Gbps (non-blocking) 1.6Gbps (non-blocking)
Throughput
(packet per second) 0.74Mpps@ 64 bytes 1.19Mpps@ 64 bytes
Address Table 1K entries, automatic source address learning
and aging
Shared Data Buer 448K bits
Flow Control IEEE 802.3x pause frame for full-duplex
Back pressure for half-duplex
ESD Protection 6KV DC
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
Connector
Removable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin
5/6 for Power 2
Alarm One relay output for power failure.
Alarm relay current carry ability: 1A @ 24V DC
LED Indicator
System:
Power 1 (Green), Power 2 (Green)
Fault Alarm (Red)
Per 10/100TX RJ45 Ports:
10/100 LNK/ACT (Green)
Dimensions
(W x D x H) 30 x 70 x 104 mm 41 x 70 x 115 mm
Weight 255g 300g
Power Requirements Dual 12~48V DC, 24V AC
Power Consumption Max. 2 watts/6.86BTU
(Ethernet full loading)
Max. 2.5 watts/8.57BTU
(Ethernet full loading)
Standards Conformance
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC60068-2-32 (free fall)
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
Standards Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX/100BASE-FX
IEEE 802.3x ow control and back pressure
IEEE 802.1p Class of Service
IEEE 802.3az Energy Ecient Ethernet (EEE)
Environment
Operating
Temperature -40 ~ 75 degrees C
Storage Temperature -40 ~ 85 degrees C
Humidity 5 ~ 95% (non-condensing)
3. Hardware Introduction
3.1 Three-View Diagram
The three-view diagram of the Industrial Ethernet Switch consists
of ve or eight auto-sensing 10/100/BASE-TX RJ45 port and one
removable 6-pin terminal block. The LED indicators are also located
on the front panel.
104.00
30.00
70.00
18.00
9.00
91.00
52.00 52.00
50.00
30.00
28.00
48.80 40.00
18.00
40.00
18.00
147.00
Mounting Kit
Mounting Kit
DIN-Rail Kit
Unit: mm
Rear ViewSide View Side View
Top View
Front View
Bottom View
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
Max . F ault Alarm Loa ding: 24V, 1A
DC Inp ut: 12-48V
, 0.17A max .
AC Inpu t: 24V
, 0.15A max .
Fault
V1+ V2 +
PWR 2PWR 1
Figure 1: ISW-500T Three-View Diagram
115.00
41.00
70.00
18.00
9.00
103.00
28.65
27.19
70.00
40.00 48.80 40.00
28.00 18.00 28.00
159.00
Top View
Front View
Mounting Kit
Mounting Kit
DIN-Rail Kit
Unit: mm
Rear View
Bottom View
Side View Side View
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
6
7
8
Max . Fault Alar m Lo ading: 24V, 1A
DC In put: 12-48 V
, 0.2A max .
AC Inpu t: 24V
, 0.16A max .
Fault
V1+ V2 +
PWR 2PWR 1
Figure 2: ISW-800T Three-View Diagram
[ISW-500T]
1. Insert positive and negative DC power wires into contacts 1 and 2 for
Power 1, or 5 and 6 for Power 2.
Max. Fault Alarm Loading: 24V, 1A
DC nput: 12-48V
, 0.17A max.
AC I ut: 24V
, 0.15A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Wire Range Wire Type Torque In-lbs (N.m)FW
12-24 AWG Str/Sol 5 (0.56)Cu 2
2. This product is intended to be supplied with a UL-listed power adapter
or power source, rated 24V AC 50/60Hz min. 0.15A or 12-48V DC
min. 0.17A, and Tma 75°C (max.).
3. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
123456
Power 1 Fault Power 2
+ - + -
Note
1. The power input range is 12V ~ 48V DC and supports
24V AC.
2. Use one power input when using 24V AC.
Note
1. La plage d’entrée d’alimentation est de 12V ~ 48V DC
et prend en charge 24V AC.
2. Utilisez une entrée d’alimentation lorsque vous utilisez
24V AC.
[ISW-800T]
1. Insert positive and negative DC power wires into contacts 1 and 2 for
POWER 1, or contacts 5 and 6 for POWER.
Max. Fault Alarm Loading: 24V, 1A
D nput: 12-48V
, 0.2A max.
AC I ut: 24V
, 0.16A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Wire Range Wire Type Torque In-lbs (N.m)FW
12-24 AWG Str/Sol 5 (0.56)Cu 2
2. This product is intended to be supplied with a UL-listed power adapter
or power source, rated 24V AC, 50/60Hz min. 0.16A or 12-48V DC,
min. 0.2A, and Tma 75°C (max.).
3. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
123456
Power 1 Fault Power 2
+ - + -
Note
1. The power input range is 12V ~ 48V DC and supports
24V AC.
2. Use one power input when using 24V AC.
Note
1. La plage d’entrée d’alimentation est de 12V ~ 48V DC
et prend en charge 24V AC.
2. Utilisez une entrée d’alimentation lorsque vous utilisez
24V AC.
3.2 Front View
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
6
7
8
Figure 3: ISW-500T Front View ISW-800T Front ViewFigure 4:
3.3 LEDDenition:
System
LED Color Function
DC1 Green Lights to indicate DC power input 1 has power.
DC2 Green Lights to indicate DC power input 2 has power.
Fault Red Lights to indicate that AC or DC power has failed.
Per 10/100BASE-TX Port
LED Color Function
10/100
LNK/ACT Green
Lights
Indicating the port is running at
10/100Mbps speed and successfully
established.
Blinks Indicating that the switch is actively
sending or receiving data over that port.
3.4 Top View
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V
, 0.17A max.
AC Input: 24V
, 0.15A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Figure 5: ISW-500T Top View
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V
, 0.2A max.
AC Input: 24V
, 0.16A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Figure 6: ISW-800T Top View
3.5 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial
Ethernet Switch is used for two DC redundant power inputs. Please
follow the steps below to insert the power wire by professionals.
Caution
When performing any of the procedures like inserting the
wires or tightening the wire-clamp screws, make sure the
power is OFF to prevent from getting an electric shock.
Caution
Lorsque vous effectuez l’une des procédures telles que
l’insertion des fils ou le serrage des vis de serrage,
assurez-vous que l’alimentation est coupée pour éviter tout
choc électrique.


Produkt Specifikationer

Mærke: Planet
Kategori: Ikke kategoriseret
Model: ISW-500T

Har du brug for hjælp?

Hvis du har brug for hjælp til Planet ISW-500T stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Planet Manualer

Planet

Planet IFGS-620TF Manual

8 Oktober 2024
Planet

Planet MTB-LB20 Manual

30 September 2024
Planet

Planet MFB-TFA40 Manual

27 September 2024
Planet

Planet MFB-F60 Manual

21 September 2024
Planet

Planet LS100-SMK Manual

6 September 2024
Planet

Planet IGS-1000-4UP2X Manual

6 September 2024
Planet

Planet NMS-AIoT Manual

6 September 2024
Planet

Planet NMS-ST Manual

6 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024
Stamos

Stamos SPT10P805 Manual

22 November 2024