1. Package Contents
Thank you for purchasing PLANET Industrial Ethernet
Switch, ISW-501T/ISW-801T. In the following sections, the
term Industrial Ethernet Switch means the ISW-501T
or ISW-801T.
Open the box of the Industrial Ethernet Switch and carefully
unpack it. The box should contain the following items:
Industrial Ethernet
Switch x 1
User’s Manual x 1 RJ45 Dust
Cap x 5 (8)
DIN-rail Bracket w/
Screws x 1
Wall-mount Plate
w/Screws x 1 set
If any of these are missing or damaged, please contact
your dealer immediately; if possible, retain the carton
including the original packing material, and use them again
to repack the product in case there is a need to return it to
us for repair.
2.2 LED Indicators
LED Color Function
P1 Green Lit: indicates Power 1 has power.
P2 Green Lit: indicates Power 2 has power.
FAULT Green Lit: indicates either Power 1 or Power
2 has no power.
10/100
LNK/ACT Green
Lit: indicates the Switch is
successfully connecting to the
network at 100Mbps or 10Mbps.
O: indicates that the Switch is not
successfully connecting to the
network at 100Mbps or 10Mbps.
Blinking: indicates that the Switch is
actively sending or receiving data over
that port.
2.3 Switch Upper Panel
The upper panel of the Industrial Ethernet Switch consists
of one terminal block connector within two DC power
inputs.
2.6 Grounding the Device
Users MUST complete grounding wired with the device;
otherwise, a sudden lightning could cause fatal damage to
the device.
Max. fault loading: 24V, 1A
V1+ V2+
PWR1 PWR2Fault
DC Input: 12-48V
, 1.2A max.
AC Input: 24V
, 1.1A max.
1 2 3 4 5 6
Earth Ground
Note
EMD (Lightning) DAMAGE IS NOT CONVERED
UNDER WARRANTY.
2. Tighten the wire-clamp screws for preventing the wires
from loosening.
1 2 3 4 5 6
V1+ V1- V2+ V2-
Power 1 Power 2Fault
Note
1. The wire gauge for the terminal block should
be in the range between 12 and 24 AWG.
2. The power input range is DC 12V ~ 48V and
supports AC 24V.
3. Use one power input when using AC 24V.
2. Hardware Introduction
2.1 Switch Front Panel
The front panel of the Industrial Ethernet Switch consists of
Ethernet interfaces and LED indicators.
Front View
P1 P2 Fault
10 /10 0
ACT
LNK
2
3
4
5
1
P1 P2 Fault
6
7
8
5
2
3
4
1
10/100
ACT
LNK
Figure 1: ISW-501T Front
View
Figure 2: ISW-801T Front
View
Figure 3 shows the upper panel of the Industrial Ethernet
Switch.
Max. fault loading: 24V, 1A
V1+ V2+
PWR1 PWR2Fault
DC Input: 12-48V
, 1.2A max.
AC Input: 24V
, 1.1A max.
1 2 3 4 5 6
Figure 3: ISW-501T and ISW-801T Top View
2.4 Wiring the Power Inputs
The Upper Panel of the Industrial Ethernet Switch indicates
a DC inlet power socket and consis of one terminal block ts
connector within 6 contacts. Please follow the steps below
to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1
and 2 for Power 1, or 5 and 6 for Power 2.
Max. fault loading: 24V, 1A
V1+ V2+
PWR1 PWR2Fault
DC Input: 12-48V
, 1.2A max.
AC Input: 24V
, 1.1A max.
1 2 3 4 5 6
2.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal
block connector as the picture shows below. Inserting the
wires, the Industrial Ethernet Switch will detect the fault
status of the power failure, or port link failure and then
forms an open circuit. The following illustration shows an
application example for wiring the fault alarm contacts.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should
be in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V, 1A
current (max.).
3. Installation
This section describes the functionalities of the Industrial
Ethernet Switch’s components and guides you to installing
it on the DIN rail and wall. Please read this chapter
completely before continuing.
Note
This following pictures show how to install the
device. However, the device in the picture is
not ISW-501T or ISW-801T.
3.1 DIN-rail Mounting Installation
1
2
3.2 Wall-mount Plate Mounting


Produkt Specifikationer

Mærke: Planet
Kategori: Ikke kategoriseret
Model: ISW-801T

Har du brug for hjælp?

Hvis du har brug for hjælp til Planet ISW-801T stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Planet Manualer

Planet

Planet IFGS-1222TF Manual

7 December 2024
Planet

Planet IFGS-620TF Manual

8 Oktober 2024
Planet

Planet MTB-LB20 Manual

30 September 2024
Planet

Planet MFB-TFA40 Manual

27 September 2024
Planet

Planet MFB-F60 Manual

21 September 2024
Planet

Planet LS100-SMK Manual

6 September 2024
Planet

Planet IGS-1000-4UP2X Manual

6 September 2024
Planet

Planet NMS-AIoT Manual

6 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024