Rolls MU118 Manual


Læs nedenfor 📖 manual på dansk for Rolls MU118 (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
ROLLS DIGITAL MULTIMETER
MU118 OPERATION MANUAL
1. INTRODUCTION
This instrument is compact, rugged, battery operated, handheld 3
1/2 digit digital multimeter for measuring DC and AC voltage, DC
and AC current, resistance and diode, capacitance, transistor,
continuity test, temperature and frequency.
The dual–slope A-D converter uses C-MOS technology for
auto-zeroing, polarity selection and over-range indication. Full
overload protection is provided. It is an ideal instrument for use in
the field, laboratory, workshop, hobby and home applications.
2. FEATURES
* Push-button ON-OFF power switch.
* Single 30 position easy to use rotary switch for function and range
selection.
* High sensitivity of 10V.
* Automatic over range indication with the 1” displayed.
* Automatic polarity indication on DC range.
* All ranges fully protected.
* Resistance measurements 0.1 to 200M.
* Capacitance measurements 1pF to 20µF.
* Diode testing with 1mA fixed current.
* Transistor hFE test with Ib100µA.
* Temperature measurement with or without K type thermocouple.
3. SPECIFICATIONS
Accuracies are ± (% reading + No. of digits)
Operating environment: 25, less than 75% R.H.
DC Voltage
Range Accuracy Resolution
200mV ±(0.5% of rdg + 3d) 100μV
2V 1mV
20V 10mV
200V 100mV
1000V ±(0.8% of rdg + 3d) 1V
Input impedance: 10M ohm on all ranges.
Overload Protection: 1000V DC or peak AC on all ranges.
AC Voltage
Range Accuracy Resolution
2V ±(0.8% of rdg + 3d) 1mV
20V 10mV
200V 100mV
750V ±(1.2% of rdg + 5d) 1V
Input impedance: 10M on all ranges
Frequency range: 40Hz to 400Hz.
Overload protection: 700V rms or 1000V peak continuous on ac
ranges, except 200mV ac range (15 seconds maximum above
300V rms).
Indication: Average (rms of sine wave)
DC Current
Range Accuracy Resolution
20mA ±(0.8% of rdg + 2d) 10μA
200mA ±(1.2% of rdg + 2d) 100μA
10A ±(2% of rdg + 5d) 10mA
Overload protection: 0.2A/250V fuse. (20A range not fused)
Maximum input current: 20A, 15 sec. max.
AC Current
Range Accuracy Resolution
20mA ±(1% of rdg + 3d) 10μA
200mA ±(1.8% of rdg + 3d) 100μA
10A ±(3% of rdg + 7d) 10mA
Overload protection: 0.2A/250V fuse. (20A range not fused.)
Frequency range: 40Hz to 400Hz.
Maximum input current: 10A, 15 sec. max.
Indication: Average (rms of sine wave)
Resistance
Range Accuracy Resolution
200 ±0.8% of rdg ± 3d 0.1
2k ±0.8% of rdg ± 2d 1
20k 10
200k 100
2M 1k
20M ±1% of rdg ± 5d 10k
200M ±[5% of (rdg -1M) +10d] 10k
On 200Mrange, if short the two test leads, display reading is 10
digits should be subtracted from measurement results.
Capacitance
Range Accuracy Resolution
2nF ±(3% of rdg + 5d)
1pF
20nF 10pF
200nF 100pF
F 1nF
20µF 10nF
Temperature
Range Accuracy Resolutio
n
-50~400 ±(1.2% of rdg + 4d) 1
400~1000 ±(1.9% of rdg + 15d) 1
*Using K type thermocouple probe.
Frequency Test
Overload protection: AC 220V rms.
4. GENERAL CHARACTERISTICS
Maximum display: 1999 counts (3
1
/2 digits) with automatic polarity
indication and eng. unit.
Indication method: LCD display.
Measuring method: Dual-slope integration A-D converter system.
Overrange indication: 1” or-1” figure only in the display.
Maximum common mode voltage: 500V DC/AC rms.
Reading rate: 2~3 reading per sec. (approximate).
Temperature for guaranteed accuracy: 25.
Temperature ranges: Operating: 0 to 40 (32 to 104)
Storage: -10 to 50 (14 to 122)
Power supply: One 9V battery (NEDA 1604 or 6F22 or equivalent).
Low battery indication: to lift of display.
Size: 88 (W) × 170 (D) × 38(H) mm.
Weight: 340g (including battery)
Accessories: Operating manual, set of test leads and thermocouple
(K type, 300)
5. OPERATION
1. Check the 9-volt battery by setting the ON-OFF switch to ON. If the
battery is weak, a sign will appear on the display. It is does not
appear on the display, proceed as below. See maintenance if the
battery has to be replaced.
2. The mark or sign next to the test lead jacks is for warning that
the input voltage or current should not exceed the indicated
values. This is to prevent damage to the internal circuit.
3. The function switch should be set to the range which you want to
test before operation.
4. If the voltage or current range is not known beforehand set the
function switch to a high range and work down.
5. When only the figure 1 is displayed, over-range is being indicated
and the function switch must be set to a higher range.
5.1) DC Voltage Measurement
1, Connect the BLACK test lead to the COM jack and the RED test
lead to the V/ jack.
2. Set the FUNCTION switch to the “V range to be used and
connect the test leads across the source or load under
measurement. The polarity of the RED lead connection will be
indicated at the same time as the voltage.
NOTE:
Do not apply more than 1000V to the input, Indication is
possible at higher voltages but there is danger of damaging the


Produkt Specifikationer

Mærke: Rolls
Kategori: Ikke kategoriseret
Model: MU118

Har du brug for hjælp?

Hvis du har brug for hjælp til Rolls MU118 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Rolls Manualer

Rolls

Rolls HR341 Manual

6 September 2024
Rolls

Rolls PM61 Manual

6 September 2024
Rolls

Rolls MP213 Manual

6 September 2024
Rolls

Rolls MS112 Manual

4 September 2024
Rolls

Rolls HA204p Manual

3 September 2024
Rolls

Rolls RA53b Manual

3 September 2024
Rolls

Rolls DB125 Manual

3 September 2024
Rolls

Rolls RA102 Manual

2 September 2024
Rolls

Rolls SX95 Manual

2 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Atlona

Atlona AT-DVIF30S-IR Manual

29 December 2024
Atlona

Atlona AT-PRO3HD66M Manual

29 December 2024
Atlona

Atlona AT-3GSDI500 Manual

29 December 2024
BlueBuilt

BlueBuilt BBMAG2M Manual

29 December 2024
Atlona

Atlona AT-3GSDI-14 Manual

28 December 2024
Atlona

Atlona AT-COMP10SS Manual

28 December 2024
Atlona

Atlona AT-2VGA300SL Manual

28 December 2024
Atlona

Atlona AT-HD-V216 Manual

28 December 2024
Atlona

Atlona AT-VGA11S Manual

28 December 2024
True

True TC900 Manual

28 December 2024