T710 Access Point
Quick Setup Guide
This Mounting Guide provides step-by-step instructions on how to
field-install the Ruckus Wireless T710 access point (AP).
For detailed information on planning the installation, performing a site
survey, and operating the T710, refer to the ZoneFlex Outdoor Access
Point User Guide, available at https://support.ruckuswireless.com.
WARNING: Only trained and qualified personnel should be allowed to
install, replace, or service this equipment.
WARNING: Installation of this equipment must comply with local and
national electrical codes.
CAUTION: Make sure that you form a 80mm - 130mm (3”-5”) drip
loop in any cable that is attached to the AP or the building. This will
prevent water from running along the cable and entering the AP or the
building where the cable terminates.
CAUTION: Be sure that grounding is available and that it meets local
and national electrical codes. For additional lightning protection, use
lightning rods and lightning arrestors.
CAUTION: Make sure that proper lightning surge protection
precautions are taken according to local electrical code.
WARNING: Ruckus Wireless strongly recommends that you wear eye
protection before mounting the T710.
T HIS GUIDE IN OTHER LANGUAGES
请从以下网站获得该指南的简体中文版
https://support.ruckuswireless.com.
Vous trouverez la version française de ce guide à l'adresse suivante
https://support.ruckuswireless.com.
⽇本語版 https://support.ruckuswireless.com
ご 覧
이 가이드의 한국어 버전은 사이트
(https://support.ruckuswireless.com) .에서 확인하시기 바랍니다
Veja a versão em português (Brasil) deste guia em
https://support.ruckuswireless.com.
Puede ver la versión en español (América Latina) de esta guía en
https://support.ruckuswireless.com.
BEFORE YOU BEGIN
Before deploying your Ruckus Wireless T710, verify that all items listed
in Package Contents are included in the package. If any item is
damaged or missing, notify your authorized Ruckus Wireless sales
representative. Also, make sure that you have the required hardware
and tools.
REQUIRED HARDWARE AND TOOLS
Customer-supplied outdoor-rated three-wire (1-2mm2 or 14-
18AWG) AC cable
1/2” (13mm) flat-blade screwdriver or equivalent
No. 2 Phillips screwdriver
Small flat-blade screwdriver
Torque wrench or torque screwdriver with sockets
Long-nose pliers
Electrical wire stripping and terminal crimping pliers
Pipe or pole --OR-- a sturdy flat surface
Electric drill with drill bits and customer-supplied wall anchors, flat
washers, and hex nuts for flat-surface mount
Four factory-supplied 1/2” (12.7mm) wide stainless steel
adjustable clamps, 2.5” (63.5mm) diameter, for main mounting
bracket on smaller poles
• Ruler
PACKAGE CONTENTS
A complete T710 field installation package includes all of the items
listed below (see Figure 1for illustrations):
T710 Access Point (A)
M25 data cable gland extender (B)
Three M25 data cable glands (C)
Outdoor AP Mounting Bracket (D), consists of:
Mounting bracket
U-joint bracket
Linkage bracket
AP bracket
AC Power Cable End Connector (E)
Cable Gland Extender Flat Gasket (F)
Safety cable kit (G)
One ground wire with lug (H)
Service Level Agreement/Limited Warranty Statement
Regulatory Statement
Ruckus Wireless AP Getting Started Guide
Declaration of Conformity
This Quick Setup Guide
Figure 1: Package Contents
S TEP 1: CONNECTING AND SEALING THE RJ-45
CABLES
The T710 may use zero, or one or two RJ-45 cables, one for Ethernet
when configured as a Root AP (RAP), and another when the T710 is
supplying PoE out to a peripheral device, such as a small cell or micro
cell radio. When the T710 uses RJ-45 cables, connect and seal the
cables using the M25 data cable glands as shown in Figure 3.
WARNING: Do not use any PoE injector not tested and approved by
Ruckus Wireless to power the T710 Access Point.
WARNING: Do not plug PoE IN power into the PoE OUT port. See
Figure 2.
WARNING: If using PoE OUT, it is MANDATORY to use the custom
Ruckus supplied 60W PoE injector (part #902-0180-XX00), or to use
AC power.
WARNING: If using a PoE switch to supply power to the T710, 30W
MUST be reserved for the T710 on the switch. Failure to ensure a
30W supply may result in unpredictable operation of the access point.
Additionally, if using a PoE switch, the T710’s PoE OUT port cannot be
used to power additional devices.
Figure 2: PoE IN and PoE OUT ports
1Feed the end of the cable through the sealing nut, rubber O-ring,
clamping ring assembly and cable gland base as shown in Figure
3.
CAUTION! The minimum software revision for the T710
is ZoneFlex (ZF) 9.13 or later, or SmartZone (SZ) 3.4 or
later.
DO NOT CONNECT THE T710 TO A RUCKUS
WIRELESS ZONEDIRECTOR RUNNING 9.12.2 OR
EARLIER.


Produkt Specifikationer

Mærke: Ruckus Wireless
Kategori: Adgangspunkt
Model: ZoneFlex T710

Har du brug for hjælp?

Hvis du har brug for hjælp til Ruckus Wireless ZoneFlex T710 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Adgangspunkt Ruckus Wireless Manualer

Adgangspunkt Manualer

Nyeste Adgangspunkt Manualer

EQ-3

EQ-3 HMIP-HAP Manual

16 December 2024
Vimar

Vimar 20195.N Manual

15 December 2024
Vimar

Vimar 19195.M Manual

15 December 2024
Vimar

Vimar 20195 Manual

15 December 2024
Vimar

Vimar 19195 Manual

15 December 2024
Vimar

Vimar 14195 Manual

15 December 2024
Vimar

Vimar 14195.SL Manual

15 December 2024
Vimar

Vimar 20195.B Manual

15 December 2024
Vimar

Vimar 19195.B Manual

15 December 2024