TEST / PAIRING
SELECT
+Hr
SET
iOnce paired please close the
boiler control panel.
The LED will start flashing red.
TEST / PAIRING
+Hr
SELECT SET
RXBC605 Installation
RXBC605 Wiring Terminals
RXBC605
1
3
6
2
5
4
Remove the front panel from the boiler.
Do not remove boiler loop.
Replace the front panel ensuring a good seal is made.
Connect the electrical plug.
Pull out the mechanical timer.
Push fit boiler control into housing.
7Power up the boiler and check the correct operation.
Quick Guide
RT510BC+
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
RT510BC+ (Thermostat) Button Functions
Introduction
The RT510BC+ thermostat will switch your heating system on or o, as needed, in accordance
with the time and temperature set by you. It can be used with the RXBC605 integral plug-in RF
boiler control. The RF boiler control is a direct replacement for the basic time clock or blanking
plate usually supplied with the boiler. Installing the RF boiler control takes minutes. Once
installed, you will benefit from all the control features of the RT510BC+ thermostat.
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be tted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
+Hr
SELECT
SELECT
SET
SET
+
+
+
Key Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
Press to conrm your settings
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
Press the buttons for 3 seconds to enter Installer Mode
Press the buttons for 3 seconds to enter Clock Settings
Box content
Quick Guide 2 x AA Alkaline
Batteries 2 x Fixing Screws
RT510BC+ Desk Stand
Quick Guide
RT510BC
RT510BC+ (Thermostat) Dip Switch Settings
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
SET
3 Sec
TEST / PAIRING
+Hr
SELECT SET
3
4
Test the Pairing Process
Pairing Process
Once the LED stops flashing, press the
TEST / PAIRING button for 3 sec.
12
Begin the pairing process
End the pairing process
i
i
i
During test pairing, boiler control should ash conrming pair. If not, please follow
Pairing Process.
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
Terminal Identier Description
1 N Neutral
2 L Live input (230V AC)
3 Common terminal (volt free)COM
4 N.O. Normally Open
RXBC605 User Controls
RXBC605 Switch Position
LED - It will be on when the thermostat is demanding
heat.
Mode Switch
The AUTO / MANUAL switch allows you to turn on the
Boiler Control manually if required.
SYNC Button - This is used only for pairing the RF
communications.
Press the SYNC button for 3
seconds until LED starts ashing.
The LG+5V is ready to be paired
with your thermostat.
3 Sec
2. MANUAL mode. The user
can also move the switch to the
MANUAL position; when in this
mode, the boiler will be always turned
on and the LED indicator will also
be lit constantly. The manual mode
is only to be used as a temporary
control if problems develop with the
communication from the thermostat.
1. AUTO mode. When the switch
on the Boiler Control is in the AUTO
(normal) position, the Boiler Control
will automatically receive the RF signal
from the transmitter and control the
boiler based on the programming of
the transmitter. 1 2
When the thermostat is operating in
NORMAL mode, if the Boiler Control has
not received a signal from the transmitter
after 1 hour, the Boiler Control will turn
off the boiler, and the LED indicator will
flash constantly (two times every second).
Once the Boiler Control receives a valid
ON or OFF signal, the Boiler Control will
control the heating system accordingly.
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsupport@salus-tech.com
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
www.salus-tech.com
Issue Date: February 2018
V007
For PDF Installation guide please go to www.salus-manuals.com
TEST / PAIRING
SELECT
+Hr
SET
3 Sec
PLUS
C
O
M
P
L
I
A
N
T
Internal Temperature
Load Compensation
The DIP Switches can be found on the rear of your thermostat. For all plug-in
boiler receiver applications ensure SW1 is set to RAD.
ON
1 2
ON
NA SPAN
RAD ITLC
Control feature ITLC SPAN
Operation ITLC Internal Temperature
Load Compensation for
improved eciency.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.


Produkt Specifikationer

Mærke: Salus
Kategori: Termostat
Model: RT510BC+

Har du brug for hjælp?

Hvis du har brug for hjælp til Salus RT510BC+ stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Salus Manualer

Salus

Salus RT 520 RF Manual

23 September 2024
Salus

Salus T105RF Manual

7 September 2024
Salus

Salus IT800 WIFI Manual

4 September 2024
Salus

Salus HTRP230 Manual

2 September 2024
Salus

Salus PH60-1 Manual

22 August 2024
Salus

Salus HTRS 230 Manual

22 August 2024
Salus

Salus ST320 Manual

22 August 2024
Salus

Salus RT300 Funk Manual

21 August 2024
Salus

Salus RT520RF Manual

20 August 2024
Salus

Salus RT500 Manual

18 August 2024

Termostat Manualer

Nyeste Termostat Manualer

ATTACK

ATTACK OT80 Manual

17 December 2024
Warmup

Warmup +Kit Manual

17 December 2024
Warmup

Warmup 5iE Manual

17 December 2024
EQ-3

EQ-3 HmIP-WTH-2 Manual

16 December 2024
EQ-3

EQ-3 HMIP-WTH Manual

16 December 2024
EQ-3

EQ-3 HMIP-eTRV Manual

16 December 2024