Salus RT510LG5V+ Manual

Salus Termostat RT510LG5V+

Læs nedenfor 📖 manual på dansk for Salus RT510LG5V+ (2 sider) i kategorien Termostat. Denne guide var nyttig for 32 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
TEST / PAIRING
SELECT
+Hr
SET
iOnce paired please close the
boiler control panel.
The LED will start flashing red.
iWhen enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
+Hr
Quick Guide
RT510LG5V+
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
RT510LG5V+ (Thermostat) Button Functions
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
3 Sec
TEST / PAIRING
+Hr
SELECT TEST / PAIRING
SELECT SET
LG+5V Installation
Introduction
The RT510LG5V+ thermostat will switch your heating system on or o, as needed, in accordance
with the time and temperature set by you. It can be used with the LG+5V integral plug-in RF
boiler module. The LG+5V boiler module 868MHz is a receiver with 5V DC to control ON/OFF of
Boiler or other heat system via the RF signal transmitted from the thermostat.
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be tted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
3
4
+Hr
SELECT
SELECT
SET
SET
+
+
+
Key Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
Press to conrm your settings
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
Press the buttons for 3 seconds to enter Installer Mode
Press the buttons for 3 seconds to enter Clock Settings
Test the Pairing Process
LG+5V Switch Position
Box content
Pairing Process
Once the LED stops flashing, press the
TEST / PAIRING button for 3 sec.
The boiler receiver is When in this . OFF
mode, the boiler will not receive a signal
from the RF thermostat.
AUTO. RX will automatically receive the RF
signal from your compatible SALUS device
and control the module output so that it
switches the boiler accordingly.
MANUAL mode - Manual Override. When in
this mode, the boiler will be always turned
on and the LED indicator will also be lit
constantly.
1
1
1
4
1
2
2
2
5
2
3
3
3
6
7
Press the SYNC button for 3
seconds until LED starts ashing.
3 Sec
The LG+5V is ready to be paired
with your thermostat.
Connect the electrical plug.
The LG+5V is ready to be paired with your
thermostat.
Push t boiler control into housing.
Reverse the procedure to install the
LG+5V.
Pull down control panel cover.
Remove existing mechanical timer /
blanking plate and unscrew from plate.
Ensure boiler is isolated and switched o.
Mechanical
Timer
Blanking
Plate
LG+5V User Controls
LED - It will be on when the thermostat is demanding
heat.
Mode Switch
ON – Boiler will be on continuous
AUTO will follow time and temperature program in
the transmitter
OFF – Boiler is off
SYNC Button - This is used only for pairing the RF
communications.
Quick Guide 2 x AA Alkaline
Batteries 2 x Fixing Screws
RT510LG5V+ LG+5V
Desk Stand
Begin the pairing process
End the pairing process
i
i
When removing blanking plate, also remove visible thermostat link plug, do not remove
any internal link.
During test pairing, boiler control should ash conrming pair. If not, please follow
Pairing Process.
RT510LG5V+ (Thermostat) Dip Switch Settings
The DIP Switches can be found on the rear of your thermostat. For all plug-in
boiler receiver applications ensure SW1 is set to RAD.
TEST / PAIRING
SELECT
+Hr
3 Sec
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
Issue Date: February 2018
V016
For PDF Installation guide please go to www.salus-manuals.com
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsupport@salus-tech.com
www.salus-tech.com
PLUS
C
O
M
P
L
I
A
N
T
Internal Temperature
Load Compensation
ON
1 2
ON
NA SPAN
RAD ITLC
Control feature ITLC SPAN
Operation ITLC Internal Temperature
Load Compensation for
improved eciency.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.


Produkt Specifikationer

Mærke: Salus
Kategori: Termostat
Model: RT510LG5V+

Har du brug for hjælp?

Hvis du har brug for hjælp til Salus RT510LG5V+ stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Salus Manualer

Salus

Salus RT510RF+ Manual

12 Maj 2024
Salus

Salus WT100 Manual

24 Marts 2024
Salus

Salus RT310ISR Manual

13 Marts 2024
Salus

Salus RT310RF Manual

30 Januar 2024
Salus

Salus RT510TX+ Manual

23 Januar 2024
Salus

Salus EP101 Manual

20 September 2023
Salus

Salus RT510LG5V+ Manual

19 September 2023
Salus

Salus ST620 Manual

13 September 2023
Salus

Salus ERT 50 Manual

25 August 2023

Termostat Manualer

Nyeste Termostat Manualer