TEST / PAIRING
SELECT
+Hr
SET
iOnce paired please close the
boiler control panel.
The LED will start flashing red.
TEST / PAIRING
+Hr
SELECT SET
RXWBC605 Installation
RXWBC605
1
3
6
2
5
4
Switch off the boiler at its main supply. Remove the outer casing and front fascia to
allow access to the main control panel.
Pull top tab B upwards, then outwards to
remove blanking plate or existing control.
Replace the front fascia and boiler’s
outer casing.
First plug in the connector block C
ensuring correct orientation. Remember
to ensure the block is fully connected.
Remove cover panel A upwards to remove.
Now locate the boiler control’s four hooks
then press in and down. Replace Cover
panel A.
B
A
C
A
8
9
7
The user can also move the switch to the OFF
position; when in this mode, the boiler will not
receive a signal from the RF thermostat.
The user can also move the switch to the
MANUAL ON position; when in this mode, the
boiler will be always turned on and the LED
indicator will also be lit constantly.
A LED This LED will be on when the thermostat is
demanding heat.
B – Mode Switch:
MANUAL ON / AUTO / OFF
C SYNC Button - This is used only for pairing the RF
communications.
Now move the switch back to .AUTO
To ensure the boiler control is connected properly, please now move the switch to
MANUAL ON . The boiler should now Fire and the LED on the your boiler
control should illuminate.
RXWBC605 Switch Position
RXWBC605 User Controls
When the switch on the Boiler Module is in
the AUTO position, the boiler control will
automatically receive the RF signal from the
thermostat and control the module output so
that it switches the boiler accordingly.
Before switching the boiler on at its mains supply, ensure the module switch is in the
OFF .position Ø
SYNC Button
Ensure the switch on the RF
integral boiler module is in the
AUTO position.
Gently press and hold the SYNC
button with a blunt object. After 3
seconds the Boiler Control LED will
flash once every second to indicate it
is ready to pair and ready to receive
a signal from the thermostat.
A B C
Quick Guide
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
RT510WBC+ (Thermostat) Button Functions
Introduction
The RT510WBC+ thermostat will switch your heating system on or o, as needed, in accordance
with the time and temperature set by you. It can be used with the RXWBC605 integral plug-
in RF boiler control. The RF boiler control is a direct replacement for the basic time clock or
blanking plate usually supplied with the boiler. Installing the RF boiler control takes minutes.
Once installed, you will benefit from all the control features of the RT510WBC+ thermostat.
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be tted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
+Hr
SELECT
SELECT
SET
SET
+
+
+
Key Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
Press to conrm your settings
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
Press the buttons for 3 seconds to enter Installer Mode
Press the buttons for 3 seconds to enter Clock Settings
Box content
Quick Guide 2 x AA Alkaline
Batteries 2 x Fixing Screws
RT510WBC+ Desk Stand
i
RT510WBC+ (Thermostat) Dip Switch Settings
Boiler may re up on pre-heat mode on rst turn on. If it does, it is advisable to
temporarily turn o your pre-heat until installtion is complete.
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
3 Sec
TEST / PAIRING
+Hr
SELECT
3
4
Test the Pairing Process
Pairing Process
Once the LED stops flashing, press the
TEST / PAIRING button for 3 sec.
12
Begin the pairing process
End the pairing process
i
i
During test pairing, boiler control should ash conrming pair. If not, please follow
Pairing Process.
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
Issue Date: February 2018
V016
For PDF Installation guide please go to www.salus-manuals.com
TEST / PAIRING
SELECT
+Hr
3 Sec
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsupport@salus-tech.com
www.salus-tech.com
PLUS
C
O
M
P
L
I
A
N
T
Internal Temperature
Load Compensation
The DIP Switches can be found on the rear of your thermostat. For all plug-in
boiler receiver applications ensure SW1 is set to RAD.
ON
1 2
ON
NA SPAN
RAD ITLC
Control feature ITLC SPAN
Operation ITLC Internal Temperature
Load Compensation for
improved eciency.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.


Produkt Specifikationer

Mærke: Salus
Kategori: Termostat
Model: RT510WBC+

Har du brug for hjælp?

Hvis du har brug for hjælp til Salus RT510WBC+ stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Salus Manualer

Salus

Salus RT 520 RF Manual

23 September 2024
Salus

Salus T105RF Manual

7 September 2024
Salus

Salus IT800 WIFI Manual

4 September 2024
Salus

Salus HTRP230 Manual

2 September 2024
Salus

Salus PH60-1 Manual

22 August 2024
Salus

Salus HTRS 230 Manual

22 August 2024
Salus

Salus ST320 Manual

22 August 2024
Salus

Salus RT300 Funk Manual

21 August 2024
Salus

Salus RT520RF Manual

20 August 2024
Salus

Salus RT500 Manual

18 August 2024

Termostat Manualer

Nyeste Termostat Manualer

ATTACK

ATTACK OT80 Manual

17 December 2024
Warmup

Warmup +Kit Manual

17 December 2024
Warmup

Warmup 5iE Manual

17 December 2024
EQ-3

EQ-3 HmIP-WTH-2 Manual

16 December 2024
EQ-3

EQ-3 HMIP-WTH Manual

16 December 2024
EQ-3

EQ-3 HMIP-eTRV Manual

16 December 2024