Samsung AR09HPFSEWKNJO Manual

Samsung Ikke kategoriseret AR09HPFSEWKNJO

Læs nedenfor 📖 manual på dansk for Samsung AR09HPFSEWKNJO (54 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 13 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/54
AR HCFN Series✴✴ ✴✴
AR HPFN Series✴✴ ✴✴
AR HPFS Series✴✴ ✴✴
Air Conditioner
user & installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
This manual is made with 100% recycled paper.
English-2
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB
cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment
or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government oce, for details of where
and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic
accessories should not be mixed with other commercial wastes for disposal.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
Features of your new air conditioner
2-step cooling
2-step cooling function will quickly cool the room to reach the set temperature and then it
will adjust the fan speed and air flow direction automatically to help you stay comfortable and
refreshing.
Fast cooling
If you want the strong and cool air, just select Fast function! It will get you the strongest air!
Comfort cooling
If you want the comfortable and refreshing air, Comfort function will spread the cool air indirectly to
you, so that you can stay comfortable.
Single User
Use Single User function when you are alone at home. Single User function will minimize the
energy consumption with inverter technology and reduce your electricity bill by adjusting the
maximum operating capacity of the compressor.
Easy Filter
There is no grille to remove before separating the lter from the air conditioner! Therefore,lter can
be cleaned easily, more frequently! Frequent lter cleaning will prevent dust from entering into the
product or accumulating on the lter.
Smart Install
When the installation is done, your product will examine itself through trial operation to check if it
was installed properly.
Easy Installation
It’s so easy to install! You can easily hang the product on the wall and connect the pipes and wires
by opening the cover on the bottom of the product. Now you won’t have to tilt the product to
connect the pipe and the wires!
function
function will allow you to have deep, good night’s sleep by adjusting the
temperature, fan speed and air ow direction.
English-3
Contents
Preparation
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Checking before use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Basic function
Checking the name of the parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Checking the remote controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Basic function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Adjusting the airow direction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Timer
Setting the On/Off timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
mode ....................................................................................................................... 19
Options
2-Step cooling function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Using the Fast function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Using the Comfort function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Using the
Single User
function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Settings
Using the Auto Clean function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Setting the Beep sound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Others
Cleaning the air conditioner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Maintaining the air conditioner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Troubleshooting 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Choosing the installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Accessories 34 .................................................................................................................................
Fixing the installation plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Disassembling/Assembling the Cover panel for indoor unit installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Connecting the assembly cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Installing and connecting the assembly pipe of the indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Evacuating the indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Cutting or extending the pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Installing and connecting the drain hose of the indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Changing direction of the drain hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Installing and connecting the drain hose of the outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Evacuating the connected pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Performing the gas leak tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Fixing the indoor unit in place. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Fixing the outdoor unit in place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Smart Install mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Final check and trial operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Pump down procedure (when removing the product) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
How to connect your extended power cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
English-4
Safety precautions
Before using your new air conditioner, please read this manual thoroughly to ensure
that you know how to safely and eciently operate the extensive features and
functions of your new appliance.
Because the following operating instructions cover various models, the
characteristics of your air conditioner may dier slightly from those described in this
manual. If you have any questions, call your nearest contact center or nd help and
information online at www.samsung.com.
Important safety symbols and precautions:
WARNING
Hazards or unsafe practices that may result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor
personal injury or property damage.
Follow directions. Cut-o the power supply.
Do NOT attempt. Do NOT disassemble.
Make sure the machine is grounded to prevent electric shock.
FOR INSTALLATION
WARNING
Use the power line with the power specications of the product or higher
and use the power line for this appliance only. In addition, do not use an
extension line.
Extending the power line may result in electric shock orre.
Do not use an electric transformer. It may result in electric shock or fire.
If the voltage/frequency/rated current condition is different, it may cause
re.
The installation of this appliance must be performed by a qualied
technician or service company.
Failing to do so may result in electric shock, fire, explosion, problems with the
product, or injury and may also void warranty on the installed product.
Install a Isolation Switch next to the Air Conditioner (but not on the panels
of the Air Conditioner)and circuit breaker dedicated to the air conditioner.
Failing to do so may result in electric shock orre.
Fix the outdoor unitrmly so that the electric part of the outdoor unit is not
exposed.
Failing to do so may result in electric shock, fire, explosion, problems with the
product.
English-5
PREPARATION01
Do not install this appliance near a heater, inammable material. Do
not install this appliance in a humid, oily or dusty location, in a location
exposed to direct sunlight and water (rain drops). Do not install this
appliance in a location where gas may leak.
This may result in electric shock orre.
Never install the outdoor unit in a location such as on a high external wall
where it could fall.
If the outdoor unit falls, it may result in injury, death or property damage.
This appliance must be properly grounded. Do not ground the appliance to a
gas pipe, plastic water pipe, or telephone line.
Failure to do so may result in electric shock, re, and explosion.
Make sure to use a socket-outlet with ground.
FOR INSTALLATION
CAUTION
Install your appliance on a level and hardoor that can support its weight.
Failing to do so may result in abnormal vibrations, noise, or problems with the
product.
Install the draining hose properly so that water is drained correctly.
Failing to do so may result in water overowing and property damage. Avoid
adding drain to waste pipes as odours may arise in the future.
When installing the outdoor unit, make sure to connect the draining hose
so that draining is performed correctly.
The water generated during the heating operation by the outdoor unit may
overflow and result in property damage.
In particular, in winter, if a block of ice falls, it may result in injury, death or
property damage.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest service center.
Do not pull or excessively bend the power line. Do not twist or tie the
power line. Do not hook the power line over a metal object, place a heavy
object on the power line, insert the power line between objects, or push
the power line into the space behind the appliance.
This may result in electric shock orre.
English-6
Safety precautions
FOR POWER SUPPLY
CAUTION
When not using the air conditioner for a long period of time or during a
thunder/lightning storm, cut the power at the circuit breaker.
Failing to do so may result in electric shock orre.
FOR USING
WARNING
If the appliance is ooded, please contact your nearest service center.
Failing to do so may result in electric shock orre.
If the appliance generates a strange noise, a burning smell or smoke, cut-
o the power supply immediately and contact the nearest service center.
Failing to do so may result in electric shock orre.
In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate
immediately without touching the power line. Do not touch the appliance
or power line.
Do not use a ventilating fan.
A spark may result in an explosion or re.
To reinstall the air conditioner, please contact your nearest service center.
Failing to do so may result in problems with the product, water leakage,
electric shock, or fire.
A delivery service for the product is not provided. If you reinstall the product in
another location, additional construction expenses and an installation fee will
be charged.
Especially, when you wish to install the product in an unusual location such as
in an industrial area or near the seaside where it is exposed to the salt in the air,
please contact your nearest service center.
Do not touch the circuit breaker with wet hands.
This may result in electric shock.
Do not turn the air conditioner o with the circuit breaker while it is
operating.
Turning the air conditioner off and then on again with the circuit breaker may
cause a spark and result in electric shock orre.
After unpacking the air conditioner, keep all packaging materials well
out of the reach of children, as packaging materials can be dangerous to
children.
If a child places a bag over its head, it may result in suffocation.
English-7
PREPARATION01
Do not insert your ngers or foreign substances into the outlet when the air
conditioner is operating.
Take special care that children do not injure themselves by inserting their
ngers into the product.
Do not touch the air ow blade with your hands orngers during the
heating operation.
This may result in electric shock or burns.
Do not insert your ngers or foreign substances into the air inlet/outlet of
the air conditioner.
Take special care that children do not injure themselves by inserting their
ngers into the product.
Do not strike or pull the air conditioner with excessive force.
This may result in re, injury, or problems with the product.
FOR USING
WARNING
Do not place an object near the outdoor unit that allows children to climb
onto the machine.
This may result in children seriously injuring themselves.
Do not use this air conditioner for long periods of time in badly ventilated
locations or near inrm people.
Since this may be dangerous due to a lack of oxygen, Open a window at least
once an hour.
If any foreign substance such as water has entered the appliance, cut-o
the power supply and contact the nearest service center.
Failing to do so may result in electric shock orre.
Do not attempt to repair, disassemble, or modify the appliance yourself.
Do not use any fuse (such as cooper, steel wire, etc.)other than the standard
fuse.
Failing to do so may result in electric shock,re, problems with the product, or
injury.
English-8
Safety precautions
FOR USING
CAUTION
Do not place objects or devices under the indoor unit.
Water dripping from the indoor unit may result inre or property damage.
(example electrical appliances)
Check that the installation frame of the outdoor unit is not broken at least
once a year.
Failing to do so may result in injury, death or property damage.
Max current is measured according to IEC standard for safety and current is
measured according to ISO standard for energy eciency.
Do not stand on top of the appliance or place objects (such as laundry,
lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.) on
the appliance.
This may result in electric shock, re, problems with the product, or injury.
Do not operate the appliance with wet hands.
This may result in electric shock.
Do not spray volatile material such as insecticide onto the surface of the
appliance.
As well as being harmful to humans, it may also result in electric shock, fire or
problems with the product.
Do not drink the water from the air conditioner.
The water may be harmful to humans.
Do not apply a strong impact to the remote controller and do not
disassemble the remote controller.
Do not touch the pipes connected with the product.
This may result in burns or injury.
Do not use this air conditioner to preserve precision equipment, food,
animals, plants or cosmetics, or for any other unusual purposes.
This may result in property damage.
Avoid directly exposing humans, animals or plants from the airow from
the air conditioner for long periods of time.
This may result in harm to humans, animals or plants.
English-9
PREPARATION01
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
FOR CLEANING
WARNING
Do not clean the appliance by spraying water directly onto it. Do not use
benzene, thinner or alcohol to clean the appliance.
This may result in discoloration, deformation, damage, electric shock or fire.
Before cleaning or performing maintenance, cut-o the power supply and
wait until the fan stops.
Failing to do so may result in electric shock or fire.
FOR CLEANING
CAUTION
Take care when cleaning the surface of the heat exchanger of the outdoor
unit since it has sharp edges.
This should be done by a qualified technician please contact your installer or
service center.
Do not clean the inside of the air conditioner by yourself.
For cleaning inside the appliance, contact your nearest service center.
When cleaning the internal lter, refer to the descriptions in the Cleaning the
air conditioner section.
Failure to do may result in damage, electric shock or fire.
SG_GOOD_A3050_IB&IM_EN_DB68-04398A_New.indd 9 8/1/2014 10:36:14 AM
English-10
Checking before use
Operation ranges
The table below indicates the temperature and humidity ranges the air
conditioner can be operated within. Refer to the table for ecient use.
Smart install
Through Smart install function, installer can check if the installation was done properly.
If the installation was not done properly, error indicator will turn on the indoor unit display.
Therefore user will know if the installation was done properly or not.
Maintaining your air conditioner
If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
If the outdoor temperature goes down to -5 °C, heating capacity may decrease as much as 60 %~70 % of specied capacity
according to the using conditions.
Mode Indoor temperature Outdoor temperature Indoor humidity Remark
Cooling 16 ˚C~ 15 ˚C~52 ˚C Relative humidity 80% or less32 ˚C AR
✴✴
HC
✴✴
AR
✴✴
HP
✴✴
Heating 27 ˚C or less -5 ˚C~24 ˚C - AR
✴✴
HP
✴✴
Dry 18 ˚C~32 ˚C 15 ˚C~52 ˚C - AR
✴✴
HC
✴✴
AR
✴✴
HP
✴✴
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type Description
Against cold air The internal fan will be o to prevent cold air when the heat pump is heating.
Defrost cycle
The internal fan will be o to defrost ice when the heat pump is heating.
Vertical airow blade will be closed during defrost cycle and it will open again during
heating operation after defrost cycle.
Protect compressor The air conditioner does not start operating immediately to help protect the compressor
of the outdoor unit after it has been started.
• IftheheatpumpisoperatinginHeatmode,Defrostcycleisactuatedtohelpremovefrostfromanoutdoorunit
that may have deposited at low temperatures.
The internal fan is switched oautomatically and restarted only after the defrost cycle is completed.
SG_GOOD_A3050_IB&IM_EN_DB68-04398A_New.indd 10 8/1/2014 10:36:14 AM
English-11
BASIC FUNCTION02
Main parts
Your air conditioner may slightly look dierent from illustration shown below depending on your model.
Checking the name of the parts
Display
Power button/
Remote controller receiver
Air lter
Air ow blade
(up and down) Air ow blade
(left and right)
Room
temperature
sensor
Air intake
Single user indicator
Timer/Auto clean indicator
Operation indicator
SG_GOOD_A3050_IB&IM_EN_DB68-04398A_New.indd 11 8/1/2014 10:36:15 AM
English-12
Checking the remote controller
Remote controller buttons
• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.
• Whenyouproperlypressthebuttonontheremotecontroller,youwillhearbeepsoundfromtheindoorunitandatransmit
indicator( ) appears on the remote controller display.
Power
Turn on/o the air
conditioner
Temp +
Increase/Decrease the
temperature by 1 ˚C.
Options
Select options during operation
Timer
Select Timer option
Directional < >
Move through the Timer,
Options or Settings menu to
make a selection
Vertical air swing
Activate/Deactivate vertical air ow
blade movement automatically
Single User
Turn on/o the Single User function
which reduces energy usage while
operating in cool mode.
Settings
Select settings
SET
Set/Cancel the selected option or
setting
Mode
Set one of the 5 operating modes
Fan
Adjust the fan speed
•Incaseyouwishtocanceltheoptionsorsettingsthatyouhavejustset,presstheOptions Settings or button again,
then the most recently selected item will blink and you may simply cancel it by pressing the SET button while
selected item is blinking.
SG_GOOD_A3050_IB&IM_EN_DB68-04398A_New.indd 12 8/1/2014 10:36:16 AM
English-13
BASIC FUNCTION02
Remote controller display
• Thesignalmaynotbereceivedproperlyifelectronicuorescentlampssuchasinverteruorescentlampsare
operating in the same space.
• Ifotherelectricalproductsoperatebytheremotecontroller,callyournearestcontactcenter.
Checking the remote controller
(Applicable in countries with separate collection systems)
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household
waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium
or lead above the reference levels in EC Directive 2006/66.
If batteries are not properly disposed of, these substances can cause harm to human health or the environment.
To protect natural resources and to promote material reuse, please separate batteries from other types of waste and recycle them through
your local, free battery return system.
Correct disposal of batteries in this product
Operation mode
indicator
Set temperature/ Time (for
Timer option) indicator
good'sleep indicator
Options indicator
Transmit indicator
Low battery indicator
Fan speed indicator
Vertical air swing indicator
Settings indicator
Low Battery warning
When the battery is exhausted,( ) will be displayed in the
remote controller display. When the icon appears, change
the batteries. The remote controller requires two 1.5 V AAA
type batteries.
Storing the remote controller
When you do not use the remote controller for long time,
remove the batteries from the remote controller and store it.
Inserting the batteries
1. Push the lever as arrow indicates on the rear side of the
remote controller and pull up.
2. Insert two AAA batteries.
Check and match the “+” and “-” signs accordingly. Make sure
you have inserted the batteries in correct position.
3. Close the cover by place it back to its original position.
You should hear click sound when the cover is locked properly.
•Makesurethatthewaterdoesnotgettotheremotecontroller.
•VirusDoctorfunctionisdisplayedontheremotecontrollerdisplaybutnotsupportedinthismodel.
English-14
Basic function
Basic operation is an operation mode that can be selected by pressing the button. Mode
Auto
In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room
temperature.
Dry
The air conditioner in Dry mode acts like a dehumidier by removing moisture from the indoor air.
Dry mode makes the air feel refreshing in a humid climate.
To activate the Dry mode, set temperature on the remote controller should be lower than indoor room temperature.
Fan
Fan mode can be selected to circulate your room. Fan mode will be helpful to refresh the stale air in your room.
Cool
In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot
season.
•Ifcurrentoutsidetemperatureismuchhigherthantheselectedindoortemperature,itmaytaketimetobringtheinner
temperature to the desired coolness.
Heat
The air conditioner heats as well as cools. Warm your room with this versatile appliance in the cold of winter.
• Fanmaynotoperateforabout3~5minutesatthebeginningtopreventanycoldblastswhiletheairconditioneris
warming up.
• Sincetheairconditionerheatstheroombytakingheatenergyfromoutdoorair,theheatingcapacitymaydecreasewhen
outdoor temperature is extremely low.
Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats
insuciently.
• OnlyHeatingmodelshavethisfunction:AR
✴✴
HP
✴✴
series
SG_GOOD_A3050_IB&IM_EN_DB68-04398A_New.indd 14 8/1/2014 10:36:17 AM
English-15
BASIC FUNCTION02
Basic function
Press the button to turn on the air conditioner.
Press the button to set the operating mode.
• EachtimeyoupresstheMode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat.
Press the button to set the desired fan speed.
Auto
(Auto)
Cool
(Auto), (Low), (Med), (High), (Turbo)
Dry
(Auto)
Fan
(Low), (Med), (High), (Turbo)
Heat
(Auto), (Low), (Med), (High), (Turbo)
Press the button to adjust the temperature.
Auto You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
Cool You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
Dry You can adjust the set temperature by 1 °C within the range of 18 °C~30 °C.
Fan Temperature adjustment is not possible.
Heat You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
• Drymodeisonlyavailableinthecoolingmode.
SG_GOOD_A3050_IB&IM_EN_DB68-04398A_New.indd 15 8/1/2014 10:36:19 AM
English-16
Adjusting the air ow direction
Air ow can be directed to your desired position.
Vertical air ow
• Adjustingtheairowdirectionisnotavailableingood'sleepmodewhileitisin
cool mode.
• However,youcanadjusttheairowdirectioningood'sleepmodewhileitisin
heat mode.
Horizontal air ow
Make sure one of the blade pin lever that stick out of the air ow blades are not broken.
Move the blade pin lever left or right to keep the air ow direction in a constant
position you prefer.
• BeextremelycarefulwithyourngerswhileadjustingtheHorizontal
air ow direction.
There is a potential risk of personal injury when the unit is
mishandled.
Blade pin lever
This function will allow you to adjust the air flow direction vertically.
Press the button to make air flow blades vertically.
Remote controller display
To keep the air flow direction in a constant direction, press the button again.
The air flow blade(s) will stop the movement.
If you adjust the vertical air flow blade manually, it may not close completely when you
turn off the air conditioner.
English-17
TIMER
03
Setting the On/Off timer
Setting the On timer
When the air conditioner is off;
Remote controller display
1. Press the Timer button.
2. Press the button until (On) indicator starts to blink.
3. Press the SET button to set the On timer.
- (On) indicator will keep blinking and you can set the time.
4. Press the button to set the time.
- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~
3hours and hour unit from 3~24 hours.
- Time can be set from minimum 30 minutes to maximum 24 hours.
5. Press the SET button to complete the On timer setting.
- (On) indicator and the set time of the timer will be displayed on the remote
controller display and the Timer indicator (
)
will be displayed on the indoor
unit display.
- On timer setting will be cancelled if you don't press the button within SET
10seconds after setting the time. Therefore, check for the (On) indicator on the
remote controller display and the Timer indicator (
)
on the indoor unit display.
Cancel
Press the button to make the set time to display as ,
and press the button.SET
Press the Power ( ) button.
Additional options available in On/Off time mode (When the remote controller is on)
You can select from Auto/Cool/Dry/Fan/Heat.
You can adjust the temperature in Auto/Cool/Dry/Heat mode.
You can adjust the fan speed in Cool/Fan/Heat mode.
• After 10 seconds from the completion of the On timer setting, only (On) indicator will remain
displayed on the remote controller display.
• If you press the Power button on the indoor unit after setting the On timer from the remote controller,
Timer indicator on the indoor unit display will disappear and the On timer will be cancelled. Even though the
On timer is cancelled, (On) indicator on the remote controller will remain displayed.
• When the On timer is set while the air conditioner is off, Timer indicator (
) will be displayed and remain on
until the On timer turns on.
English-18
Setting the Off timer
When the air conditioner is on;
Remote controller display
1. Press the Timer button.
2. Press the button until (O) indicator starts to blink.
3. Press the SET button to set the Off timer.
- (O) indicator will keep blinking and you can set the time.
4. Press the button to set the time.
- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~
3hours and hour unit from 3~24 hours.
- Time can be set from minimum 30 minutes to maximum 24 hours.
5. Press the SET button to complete the Off timer setting.
- (O) indicator and the set time of the timer will be displayed on the remote
controller display and the Timer indicator (
)
will be displayed on the indoor
unit display.
- Off timer setting will be cancelled if you don't press the button within SET
10seconds after setting the time. Therefore, check for the (O) indicator on the
remote controller display and the Timer indicator (
)
on the indoor unit display.
Cancel
Press the button to make the set time to display as ,
and press the button.SET
Press the Power ( ) button.
• O
timer may not work depending on the On/O status of the indoor
unit and the On/O status of the indicator on the remote controller
display.
• Only the latest setting timer will be applied between the On Timer/O
Timer and O timer functions.
• After setting the timer, the set time will be displayed for 3 seconds
before it disappears.
• If Timer function is used in Heating mode, Air conditioner work into
former mode. (AR✴✴ ✴✴HC series)
Combining On Timer and Off Timer
When the air conditioner is off When the air conditioner is on
When set time on On timer is shorter than O timer
Ex) On timer : 3 hours, Off timer : 5 hours
- The air conditioner will turn on after 3 hours from the
moment you have set the timer and the air conditioner will
remain on for 2 hours and then turn off automatically.
When set time on On timer is longer than O timer
Ex) On timer : 3 hours, Off timer : 1 hour
- The air conditioner will turn off after 1 hour from the
moment you have set the timer and turn on after 2 hours
from the moment it was turned off.
• Set time for the On timer and the Off timer should be different from each other.
• When the On timer and the Off timer is set, setting can be cancelled by pressing the Power button.
Setting the On/Off timer
English-19
TIMER
03
mode
For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage.
When the air conditioner is operating in Cool/Heat mode;
Remote controller display
1. Press the Timer button.
2. Press the button until ( ) indicator starts to blink.
3. Press the SET button to set the mode.
- ( ) indicator will keep blinking and you can set the time.
4. Press the button to set the time.
- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~
3hours and hour unit from 3~12 hours.
- Time can be set from minimum 30 minutes to maximum 12 hours.
- Default time setting for the mode is 8 hours.
5. Press the SET button to complete the mode setting.
- ( ) indicator and the set time of the mode will be displayed on
the remote controller display.
- Timer indicator (
)
will be displayed on the indoor unit display.
- mode setting will be cancelled if you don't press the button within SET
10 seconds after setting the time. Therefore, check for the ( ) indicator on the
remote controller display and the Timer indicator ( on the indoor unit display.)
Cancel Press the button to make the set time to display as ,
and press the button.SET
Additional options available in mode
You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
Fan speed will be adjusted automatically according to the mode.
However, If you select mode while heating operation is on, you can adjust fan speed.
When the mode is on.
InCoolmode:Airowdirectionwillbeadjustedautomatically.
InHeatmode:Adjustingairowdirectionisavailable.
Temperature and fan speed change in mode
Fall asleep: Eases you into sleep by dropping the temperature.
Sound sleep: Relaxes your body and raises your temperature slightly.
Wake up: Allows you to wake up from comfortable intermittent air and it makes you feel refreshed.
• Recommended set temperature is between 25
°C ~ 27 °C for cooling and 21 ˚C~23 ˚C for heating.
• If the set temperature is too low, you may feel cold during sleep or catch a cold.
• Optimal operation hour of mode is 8 hours. Therefore, if the time is set too short or long, you
may not feel as comfortable as you would expect.
• If the mode is set over 5 hours, Wake up stage will begin when 1 hour is remaining in the
operation time and the air conditioner will stop automatically.
• When the On timer and the function is set simultaneously, the air conditioner will only apply
the function that was set later.
English-20
2-Step cooling function
2-Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor
temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when
indoor temperature reaches set temperature.
When the air conditioner is operating in Cool mode;
Remote controller display
1. Press the Options button.
2. Press the button until (2-Step) indicator starts to blink.
3. Press the SET button to set the 2-Step Cooling function.
- (2-Step) will blink first, then remain on the display as (2-Step) and 2-Step
Cooling function will begin.
Cancel Press the button again to make the ( ) indicator blink Options 2-Step
and press the button.SET
English-21
OPTIONS04
Using the Fast function
Using the Comfort function
You can set the Comfort function to provide mild cooling.
When the air conditioner is operating in Cool mode;
Remote controller display
1. Press the Options button.
2. Press the button until (Comfort) indicator starts to blink.
3. Press the SET button to set the Comfort function.
- (Comfort) will blink first, then remain on the display as (Comfort) and Comfort
function will begin.
Cancel Press the button again to make the (Comfort) indicator blink Options
and press the button.SET
• Comfort
function is only available in Cool mode.
• Vertical air swing can be adjusted.
• Set temperature can be adjusted, but fan speed cannot be adjusted.
• If the Comfort function is selected while Single user/
function is on, corresponding function will be cancelled.
You can set the Fast function to provide fast and powerful cooling.
When the air conditioner is operating in Cool mode;
Remote controller display
1. Press the Options button.
2. Press the button until (Fast) indicator starts to blink.
3. Press the SET button to set the Fast function.
- (Fast) will blink first, then remain on the display as (Fast) and Fast function will
begin.
Cancel Press the button again to make the (Fast) indicator blink and Options
press the button.SET
• Fast function is only available in Cool mode.
• Vertical air swing can be adjusted.
• Set temperature and fan speed cannot be adjusted.
• If the Fast function is selected while Single user/ function
is on, corresponding function will be cancelled.
English-22
Using the Single User function
This function will reduce the energy usage while the air conditioner is operating in Cool mode.
When the air conditioner is operating in Cool mode;
Remote controller display
Press the button on the remote controller.Single user
"
"
appears on the remote controller display for few seconds and
disappears.
Single user indicator and air swing indicator appear automatically on the
remote controller display.
The air flow blades move up and down.
If the current set temperature is lower than 24 °C in Cool mode, it will be
automatically raised to 24 °C.
Cancel Press the button once again.Single user
• Single user function is only available in Cool mode.
• If the Single user function is selected while Fast/Comfort function is
on, corresponding function will be cancelled.
• Vertical air swing will remain on even after the Single user function is
cancelled.
Additional options available in Single user function
You can adjust the set temperature by 1 °C within the range of 24 °C ~ 30 °C in Cool mode.
(Auto), (Low), (Med), (High), (Turbo) can be selected.
Vertical air swing can be selected.
English-23
SETTING05
Using the Auto Clean function
Auto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with
clean air.
When the air conditioner is operating;
Indoor unit display
1. Press the Settings button.
2. Press the button until (Clean) indicator starts to blink.
3. Press the SET button to set the Auto clean function.
- (Clean) indicator will be displayed on the remote controller display and Timer
( ) indicator will turn on the indoor unit display. Auto clean function will be
activated after the air conditioner stops operating.
-Duration of the Auto clean function can be dierent depending on the previous
operation mode used.
Auto(cool),Cool,Drymode:30minutes.
Auto(heat),Heat,Fanmode:15minutes.
Cancel Press the button again to make the (Clean) indicator blink Settings
and press the button.SET
• When the operation mode is set during Auto clean function is activated,
the air conditioner will operate in chosen operation mode and the Auto
clean function will be re-activated when the operation stops.
• During the auto clean function, indoor fan will continue to run and air
ow blade will remain open to expel ambient air.
• lighting in Auto clean mode.
Setting the Beep sound
Beep sound from the indoor unit can be muted.
1. Press the Settings button.
2. Press the button until (Beep) indicator starts to blink.
3. Press the SET button to mute the beep sound.
English-24
Cleaning the air conditioner
Cleaning the indoor unit
Cleaning the outdoor unit heat exchanger
Wipe the surface of the unit with a slightly damp micro ber cloth when
needed.
When dust accumulates on the heat exchanger, it may decrease cooling
performance. Therefore, clean it regularly.
Spray water to clean the dust.
• Ifitisdiculttocleantheoutdoorunitheatexchangeron
your own, contact service center.
• Contacttheservicecenterwhenyoucleantheindoorunit
heat exchanger because it needs to be disassembled.
• Sincethepaneloftheindoorunitiseasilyscratched,you
should use a micro ber cloth to clean the panel.
When you use the micro ber cloth, slightly dampen the cloth
and remove any debris on the cloth to avoid scratches.
Heat exchanger
(Illustration may dier slightly
depending on the models)
Make sure to turn o the power of the indoor unit and cut-o
the power supply before cleaning the air conditioner.
CAUTION
Donotcleanthedisplayusingalkalinedetergent.
Donotusesulfuricacid,hydrochloricacid,organicsolvents
(such as thinner, kerosene and acetone etc.) to clean the
surface of the product or put any stickers on it.
They may damage the surface of the air conditioner.
CAUTION
Becarefulwiththesharpedgesonthe
outdoor unit heat exchanger.
CAUTION
English-25
OTHERS06
Cleaning the air conditioner
Removing the Airlter
There is a hole on the bottom right side of the lter. Put your
nger in that hole to get a grip on thelter and slightly push it up
to release the hooks from the bottom side. Then, pull it down to
remove the lter from the main body.
Cleaning the air lter
Washable foam based airlter captures large particles from the air. The lter is cleaned with a vacuum or by hand washing.
Remove the air filter from the main body.
Insert the air filter back in its original position. Dry the Air filter in a ventilated area.
Clean the Air filter with a vacuum cleaner or soft brush.
If dust is too heavy, rinse it with running water.
• CleantheAirlterevery2weeks.Cleaningtermmaydierdependingontheusageandenvironmentalconditions.
In dusty area, clean it once a week.
• IftheAirlterdriesinaconned(orhumid)area,odorsmaygenerate.Ifitoccurs,re-cleananddryitina
well-ventilated area.
Airlter
English-26
Cleaning the air conditioner
Reassembling the Airlter
1. Put the filter on the main body and insert the hooks which are
in the top of the Air filter into the main body.
Airlter
2. Theres one hook in both side of the filter, press the surface of
the Air filter softly and get the hooks into the main body.
3. Press the bottom of the filter lightly to securely x the main
body. ➃ ➄
English-27
OTHERS06
Maintaining the air conditioner
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.
1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours
and cut-othe power supply. There may be internal damage if moisture is left
in components.
2. Before using the air conditioner again, dry the inner components of the air
conditioner again by running in Fan mode for 3 to 4 hours. This helps remove
odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type Description Every 2
weeks
Every 3
months
Every 4
months Once a year
Indoor
unit
Clean the Full HDlter (1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the cross fan (2)
Clean the condensate drain pipe (2)
Replace the remote controller batteries (1)
Outdoor
unit
Clean the heat exchanger on the outside of the unit (2)
Clean the heat exchanger on the inside of the unit (2)
Clean the electric components with jets of air (2)
Verify that all the electric components are rmly
tightened (2)
Clean the fan (2)
Verify that all the fan assembly isrmly tightened (2)
Clean the condensate drain pan (2)
: This check mark requires checking the indoor/outdoor unit periodically.
Follow the description to maintain the air conditioner properly.
(1) The described operations should be performed more frequently if
the area of installation is very dusty.
(2) These operations must always be performed by qualied personnel.
For more detailed information, see the installation part in the
manual.
CAUTION
English-28
Troubleshooting
Refer to the following chart if the air conditioner operates abnormally. This may save
time and unnecessary expenses.
PROBLEM SOLUTION
The air conditioner
does not work at all.  Checkpowerstatusandthenoperatetheairconditioneragain.
 Pluginorswitchonthecircuitbreakerandthenoperatetheair
conditioner again.
 EnsureIsolatorisswitchon.
 CheckifyouhavesettheOTimer.Operatetheairconditioner
again by pressing the button.Power
The temperature
adjustment is not
working.
 CheckifyouhaveselectedFan/Fastmode.Inthesemodes,desired
temperature is set to auto and you cannot adjust the temperature.
Cool/Warm air does
not come out of the
air conditioner.
 Checkifthesettemperatureishigher(duringCoolmode)/
lower(during Heat mode) than the current temperature. Press the
Temp + or - button on the remote controller to change the set
temperature.
 CheckiftheAirlterisblockedbydirt.Ifthereisalotofdustonthe
Air lter, cooling(heating) performance may decrease. Clean them
frequently.
 Checkiftheoutdoorunitiscoveredorinstalledneartheobstacle.
Take the cover o and take the obstacle away.
 CheckiftheairconditionerisoperatinginDefrostmode.When
the ice formed in winter or the outdoor temperature is too low, the
air conditioner operates in Defrost mode automatically. In Defrost
mode, indoor fan stops and warm air does not come out.
 Ifthedoorsorwindowsareopen,itmaycausebadcooling
(heating) performance.
Close the doors and windows.
 Checkiftheairconditionerhasjustbeenturnedonafterstopping
cooling or heating operation. In this case, just a fan will run to
protect the outdoor unit compressor.
 Checkifthepipelengthistoolong.Whenthepipelengthexceeds
maximum allowable pipe length, cooling (heating) performance
may decrease.
Airow adjustment
is not working.
 Checkifyouhaveselected mode. In this mode, you
cannot adjust the air ow direction. (If the mode is
operating in Heat mode, you can adjust the air ow direction.)
English-29
OTHErS06
PROBLEM SOLUTION
Fan speed
adjustment is not
working.
 CheckifyouhaveselectedAuto/Dry/Fast/ mode. In
these mode, fan speed is set to Auto and you cannot adjust the fan
speed.
Remote controller is
not working.  Checkifyourbatteriesaredepleted.
 Makesurenothingisblockingyourremotecontrollersensor.
 Checkthattherearestronglightingapparatusneartheair
conditioner. Strong light which comes from uorescent bulbs or
neon signs may interrupt the electric waves.
Timer function does
not set.  CheckifyoupresstheSET button on the remote controller after
you have set the time.
The indicator
is blinking
continuously.
 PressthePower button or disconnect the power plug/switch
o the auxiliary power switch.
If the indicator is still blinking, contact the service center.
Odors permeate in
the room during
operation.
 Checkiftheapplianceisrunninginasmokyarea.Ventilatethe
room or operate the air conditioner in Fan mode for 1~2 hours.
(We do not use smelly components in the air conditioner.)
 ChecktheDrainshavebeenclearedRegularMaintenance.
Error is indicated.  Whenanindoorunitindicatorblinks,contactthenearestservice
center. Please ensure the error code is passed onto the service
center when booking the service call.
Noise is generated. • Dependingonthestatusoftheairconditionerusage,noisecanbe
heard when refrigerant ow movement changes. It is normal.
Smoke is generated
from the outdoor
unit.
 Ifmaynotbearebutitcanbeasteamgeneratedbythedefrost
operation from outdoor heat exchanger during Heat mode in
winter.
Water is dropping
from the outdoor
unit piping
connection.
 Watermaybegeneratedbecauseofthetemperaturedierence.It
is normal.


Produkt Specifikationer

Mærke: Samsung
Kategori: Ikke kategoriseret
Model: AR09HPFSEWKNJO

Har du brug for hjælp?

Hvis du har brug for hjælp til Samsung AR09HPFSEWKNJO stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Samsung Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer