Samsung MXJ-YA3100K Manual


Læs nedenfor 📖 manual på dansk for Samsung MXJ-YA3100K (3 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 14 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
INSTALLATION MANUAL
Please read Safety Precautions described in the installation manual of the air conditioner.
• Check the following parts in the package.
• For further information of the piping material and size of the refrigerant pipes, refer to the installation
manual of the air conditioner.
Branch joints
Condensate may occur on the heat insulation surface according to the atmosphere inside of the ceiling.
If the inside of the ceiling has high temperature or humidity rate is more than 80%, please add proper
insulation to prevent water drops.
The stopper area of the pipe or socket should be spread with a welding material. EX)
Requirement
±10°
or less
The
horizon
Reducer Header joint
Pipe
Adhesive insulation tape
Insulating the pipe
Insulating
header joint
Insulating after brazing the cap
Adhesive insulation tape
Insulator
Header joint
Cover the connected part and fasten the header joint using a cable tie.
Insulate the header joint and the brazed part and wrap the connected
part with an adhesive insulation tape to prevent it from dewing.
Installing the Header joint
1. Select the reducer fitted on the diameter of the pipe.
Reducer
Pipe
To indoor unit
Pipe
<Gas side>
To outdoor unit
Reducer
Pipe
To indoor unit
Pipe
<Liquid side>
To outdoor unit
Brazed part Provided
3. Install the header joint horizontally.
±15°
or less
The horizon
±10°
or less
The horizon
<Liquid side>
±15°
or less
The
horizon
The horizon
Oil balancing joint & gas side of the outdoor unit
Use an insulation with the heat resisting temperature over 120°C.
Wrap the branch joint with an insulation of a thickness of at least 10mm as shown in the diagram.
Wrap the connected part between the Outdoor joint and the gas side of the outdoor unit to
prevent it from defrosting. Wrap the oil balancing joint and gas side pipe of the outdoor unit
wholly to prevent it from dewing.
øD
øD
90°
90°
100mm or more
Cut the insulation
at the proper angle.
Cut the insulation
at the proper angle.
Wrap here with plastic tape
Use EPDM insulation.
Pipe insulation
(Field supply)
90°
Pipe
Pipe insulation
(Field supply) Insulation
(Field supply)
2. Block the reducer that is not used by brazing the cap if the number of connected indoor
unit is fewer than header joint holes.
Blocked the hole of
header joint
In order
<Gas side><Liquid side> Blocked the hole of
header joint
In order
Provided
Brazed part
Pipe
Oil balancing joint
(Field supply)
To outdoor unit
To other oil balancing joint or outdoor unit
Pipe
To other oil balancing
joint or outdoor unit
When combining 2 units, connect the oil balancing
pipe directly between the outdoor units.
Oil balancing
pipe
Installing the Oil balancing joint
Note
Connect the header joint to the pipe by cutting the provided reducer properly.
10~15mm
or more
Installing the Outdoor joint
Use the attached reducer according to the selected pipe size.
Pipe
Reducer
Reducer
Pipe
To other outdoor unit
To other outdoor joint or Y-joint of the main pipe
<Liquid side>
To other outdoor joint or outdoor unit
Pipe
Reducer
Reducer
Pipe
To other outdoor unit
To other outdoor
joint or outdoor unit
To other outdoor joint or Y- joint of the main pipe
To other outdoor unit
To other outdoor
joint or outdoor unit
Use the attached reducer according to the selected pipe size.
<Gas side>
Note
Connect the Outdoor joint to the pipe by cutting the outlet of the Outdoor joint or provided reducer properly.
10~15mm or more
<Gas side>
The horizon
Y-joint
Reducer
Model
Name MXJ-YA1509K MXJ-YA2512L MXJ-YA2812K MXJ-YA2815K MXJ-YA3119K MXJ-YA3819K MXJ-YA4422K
Liquid side
Gas side
x 2 EA
1x 2 EA
1
x 2 EA
2x 2 EA
3
x 2 EA
1x 2 EA
2
x 1 EA
7
x 1 EA
3x 1 EA
7
x 1 EA
3
x 2 EA
2x 2 EA
2
x 1 EA
4
x 1 EA
3x 1 EA
5
x 1 EA
4
x 1 EA
3x 1 EA
6
x 1 EA
5
x 1 EA
3
x 2 EA
3
x 1 EA
1
1 2 3 4 5 6 7
Model name Total indoor unit’s capacities
MXJ-YA1509K 15.0 kW and below
MXJ-YA2512L Over 15.0~40.6 kW and below
MXJ-YA2812K Over 40.6~46.4 kW and below
MXJ-YA2815K Over 46.4~69.6 kW and below
MXJ-YA3119K Over 69.6~98.6 kW and below
MXJ-YA3819K Over 98.6~139.2 kW and below
MXJ-YA4422K Over 139.2 kW
Y-joint for (High pressure gas)HR
Reducer
1 2 3
Model
MXJ-YA1500K MXJ-YA2500K MXJ-YA3100K MXJ-YA3800K
x 2 EA
1x 1 EA
2
x 1 EA
1
x 1 EA
3
x 1 EA
2
x 1 EA
1
Model name Total indoor unit’s capacities
MXJ-YA1500K 23.2 kW and below
MXJ-YA2500K Over 23.2~69.6 kW and below
MXJ-YA3100K Over 69.6~139.2 kW and below
MXJ-YA3800K Over 139.2 kW
Header joint
Model
Name MXJ-HA2512K MXJ-HA3115K MXJ-HA3819K
Liquid side
Gas side
x 4 EA
1x 1 EA
a7
x 1 EA
2x 8 EA
1x 1 EA
b7
x 1 EA
4x 1 EA
c7
x 8 EA
1
x 4 EA
3x 1 EA
8x 2 EA
8x 2 EA
8
x 1 EA
5x 8 EA
3x 1 EA
6x 8 EA
3
Reducer
1 2 3 4 5 6
7a b c
Model name Total indoor units
capacities
The maximum
quantity of connection
MXJ-HA2512K 46.4 kW and below 4
MXJ-HA3115K 69.6 kW and below 8
MXJ-HA3819K Over 69.6kW ~
139.2KW and below 8
Outdoor joint for (High pressure gas)HR
Model
MXJ-T3100 MXJ-T3800
x 1 EA
3
x 1 EA
2
x 1 EA
1
x 1 EA
6
x 1 EA
5
x 1 EA
4
Reducer
1 2 3 4 5 6
Model name Total outdoor unit’s capacities
MXJ-T3100 Below 48 HP
MXJ-T3800 Above 50 HP
Installation of outdoor joints
Do not install the outdoor
joint in this direction.
Liquid pipeGas pipe
Oil balancing
pipe
High pressure gas pipe
Connecting Method
Installing the Y-joint
Insulating the branch joint
Y-joint & liquid side of the outdoor unit
Attach the insulation provided with a branch joint to the insulation supplied in the eld
without a gap. Wrap the connected part with an insulation (Field supply) of a thickness of at
least 10mm.
Use an insulation with the heat resisting temperature over 120°C.
Wrap the branch joint with an insulation of a thickness of at least 10mm.
When insulating in high humidity(higher than 3C, 80%), wrap the supplied insulation with
more than 10mm of extra insulation such as Polyethylene Foam or other similar material.
Attach the adhesive insulation tape to the pipe
as shown in the picture after insulating the pipe.
Insulation tape
(Field supply)
Pipe insulation
(Field supply)
Pipe
Fix securely without any gap.
Pipe insulation
Provided
Fix securely
without any gap.
Pipe insulation
(Field supply)
Pipe insulation
(Field supply)
150mm Branch
Y-joint
A thickness of the insulation (Field supply)
should be at least 10mm.
(Field supply)
Connect the header joint in order respecting the number of the indoor unit.
Connet the indoor unit as the highest capacity comes first.
Install the Y-joint horizontally or ‘vertically’.
<Install vertically>
<Using reducer>
- Use connection part of Y-joint or provided
reducer by cutting them in accordance with
diameter of connecting pipe.
- Make certain 10~15mm or more for reducer
which connected with pipe.
- Remove burr on cut part of reducer.
It is impossible to connect reducer with pipe,
if pipe is deformed or reducer is untrimmed.
10~15mm
or more
Keep a minimum distance of 500mm or more before
connecting a branch joint.
<Install horizontally>
Maintain ±15° on
the horizon
Install the Y-joint within ±15° on
the horizon or on the vertical.
500mm
or more
Main pipe
To outdoor unit
Pipe
Front
Rear
Rear
Pipe
Reducer
To other branch
joints or indoor unit
Reducer
Do not insert the pipe deeply into the Y-joint.
( Do not insert more than 70mm.)
<Insertion depth of the connecting pipe>
Connecting pipe Connecting pipe
Basic specification
When cutting the connection part
Outdoor joint
Model
Name MXJ-T3819 MXJ-T4422 MXJ-TA3819L MXJ-TA4422L
Liquid side
x 2 EA
1x 2 EA
1
Gas side
x 2 EA
3
x 1 EA
2
x 1 EA
6
x 1 EA
5
x 1 EA
4
x 1 EA
7
x 1 EA
3
x 1 EA
5
x 1 EA
6
Model name Total outdoor unit’s capacities
MXJ-T3819 /MXJ-TA3819L Below 48 HP
MXJ-T4422 /MXJ-TA4422L Above 50 HP
Reducer
1 2 3 4 5
6 7
55
90
20
ID ø22.4
ID ø19.2
OD ø15.9
8
DB98-33821A-07
This marking on the product, accessories or literature indicates that the product and its
electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with
other household waste.
For correct disposal of this product, please visit http://www.samsung.com/weee.pdf


Produkt Specifikationer

Mærke: Samsung
Kategori: Ikke kategoriseret
Model: MXJ-YA3100K

Har du brug for hjælp?

Hvis du har brug for hjælp til Samsung MXJ-YA3100K stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Samsung Manualer

Samsung

Samsung DA-F680 Manual

10 November 2024
Samsung

Samsung DA-E560 Manual

10 November 2024
Samsung

Samsung MM-UC8H Manual

22 Oktober 2024
Samsung

Samsung HG32AJ570NK Manual

13 Oktober 2024
Samsung

Samsung CS-21A11MH Manual

4 Oktober 2024
Samsung

Samsung MR-EH01 Manual

3 Oktober 2024
Samsung

Samsung CS21A551ML Manual

1 Oktober 2024
Samsung

Samsung Guru 1200 Manual

27 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Gigabyte

Gigabyte ODIN GT 550W Manual

23 November 2024
Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024