StarTech.com GNDBAR1U Manual


Læs nedenfor 📖 manual på dansk for StarTech.com GNDBAR1U (2 sider) i kategorien niet gecategoriseerd. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Instruction manual
DE: Bedienungsanleitung - de.startech.com
FR: Guide de l'utilisateur - fr.startech.com
ES: Guía del usuario - es.startech.com
IT: Guida per l'uso - it.startech.com
NL: Gebruiksaanwijzing - nl.startech.com
PT: Guia do usuário - pt.startech.com
Manual Revision: 05/07/2015
For the latest information, technical specications, and support for
this product, please visit www.startech.com/GNDBAR1U.
Packaging contents
1 x copper grounding bar (1U or 10U)
12 x M5 (20 mm) screws
2 x M5 cage nuts
1 x instruction manual
System requirements
A server rack with 1U of free space (horizontal installation) or 10U
of free space (vertical installation)
System requirements are subject to change. For the latest
requirements, please visit www.startech.com/GNDBAR1U.
GNDBAR1U
Copper grounding bar for server racks
*actual product may vary from photos
Product overview
Install the grounding bar
The grounding bar can be installed either horizontally or vertically,
and can be installed on the inside or the outside of your server rack.
Using the holes located along the length of the grounding bar, you
can connect and ground up to ten devices.
1. Decide whether you want to install the grounding bar horizontally
or vertically, and select the area on your server rack where you
want to install the grounding bar.
2. Insert the included M5 cage nuts in the holes in your server rack
that line up with the mounting holes on the end of the grounding
bar.
3. Line up the mounting holes on the end of the grounding bar with
the holes in which you inserted the cage nuts.
4. Holding the grounding bar in place, insert the included M5 (20
mm) screws into the mounting holes located on each end of the
grounding bar.
5. Use a screwdriver to tighten the screws.
6. Attach the devices that you want to ground to the holes located
along the length of the grounding bar.
Note: If you install the grounding bar vertically and inside of the
server rack, the mounting screws used to hold equipment may need
to be replaced with the provided M5 (20 mm) screws.
Mounting hole Grounding hole


Produkt Specifikationer

Mærke: StarTech.com
Kategori: niet gecategoriseerd
Model: GNDBAR1U

Har du brug for hjælp?

Hvis du har brug for hjælp til StarTech.com GNDBAR1U stil et spørgsmål nedenfor, og andre brugere vil svare dig




niet gecategoriseerd StarTech.com Manualer

niet gecategoriseerd Manualer

Nyeste niet gecategoriseerd Manualer

Pioneer

Pioneer CA-R-CG.001 Manual

18 September 2024
Pioneer

Pioneer CA-R-MAC.001 Manual

18 September 2024
Pioneer

Pioneer CA-R-PI.187 Manual

18 September 2024
NEC

NEC LED-FE019i3 Manual

18 September 2024
Exquisit

Exquisit EKS180-4-060E Manual

18 September 2024
Smeg

Smeg SA661X Manual

18 September 2024
Pioneer

Pioneer CA-R-TOY.003AE Manual

18 September 2024
Pioneer

Pioneer CA-R-LA.001 Manual

18 September 2024
SereneLife

SereneLife SLTLWS550 Manual

18 September 2024
SereneLife

SereneLife SLTLWS650 Manual

18 September 2024