Description:
This system contains a STI-6400 with a DPDT key switch
to be mounted on one side of a door or wall; and a
similar looking housing, also with a DPDT key switch,
but without an alarm for the opposite side of the door.
An authorized person with a key can disable the alarm
on either side of the door. When disabled, and LED will
illuminate, and the door can be opened without setting
off the alarm. After passing through the door, the
alarm can be armed again from the opposite side.
Installation:
1. Follow STI-6400 mounting instructions and set
switches to the desired positions for alarm timing
and volume.
2. For straight through door or wall installation, mark
the center of the 5/16 inch hole in the mounted
base, then remove the base from the door or wall.
3. Drill a 5/16 inch diameter hole through the door or
wall at the marked location.
4. Align the same diameter hole in the secondary unit
base to the back side of the door or wall and
mount.
5. Route the wire from the STI-6400 unit through the
hole and into the secondary unit.
6. Attach the 6 wires to the terminal block pins 2 thru
7 matching wire colors on the terminal block label.
7. Seal the hole around the wires with an effective
fire stop material, if required.
8. Attach the battery in the secondary unit and install
the cover.
9. Cycle the key switch to be sure the LED’s turn “ON”
and “OFF”. Leave the LED’s “ON” until ready to test
the alarm.
10. Attach the battery to the STI-6400 and install the
cover.
11. Close the door and test.
Operation:
1. With the door closed, turn either key switch to arm
the alarm. The LED’s on both sides of the door
should turn “OFF”.
2. If the door is opened while the LED’s are “OFF”,
then the alarm will sound according to the switch
settings of the STI-6400.
3. To reset the alarm, turn either key to the opposite
position (the LED’s will turn “ON”), close the door
and turn either key switch again (the LED’s will turn
“OFF”).
4. When the system is armed, authorized passage can
be accomplished by turning either key switch until
the LED’s turn “ON”, and remove key. The door can
now be opened without sounding the alarm. When
passage is complete, close the door, turn the key
switch (the LED’s will turn “OFF”). The door alarm
is once again armed.
Addendum for STI-6406 with Dual Access Control
Schematic Diagram:
13 February 2017


Produkt Specifikationer

Mærke: STI
Kategori: Røgalarm
Model: -6404
Vekselstrømsindgangsspænding: 9 V
Strømkilde type: DC
Alarm decibel: 105 dB
Hørbar alarmtype: Brandhorn/sirene
Brandalarm kontrolenhed: Ingen
Røgdetektor: Ingen
Carbonmonoxid (CO) detektor: Ingen
Varmedetektor: Ingen
Lydbar alarmenhed ved nødsituation: Ingen