Supermicro SuperServer SYS-121H-TNR Manual

Supermicro Server SuperServer SYS-121H-TNR

Læs nedenfor 📖 manual på dansk for Supermicro SuperServer SYS-121H-TNR (1 sider) i kategorien Server. Denne guide var nyttig for 3 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
Board Layout
SuperServer 121H-TNR Quick Reference Guide
Caution and Product Resources
IMPORTANT: See installation instructions and
safety warning before connecting system to
power supply.
http://www.supermicro.com/about/policies/
safety_information.cfm
SAFETY INFORMATION:
Always be sure all power supplies for this system have
the same power output. If mixed power supplies are
installed, the systemwill not operate.
CAUTION:
To reduce risk of electric shock/damage to
equipment, disconnect power from server by
disconnecting all power cords from electrical
outlets. If any CPU socket empty, install
protective plastic CPU cap.
WARNING:
CAUTION:
This unit has redundant power sources.
Please disconnect all the power cords before servicing.
For more information go to:
http://www.supermicro.com/support
PRODUCT RESOURCES:
LBL-2508-T-QRG Rev 1.0
Front View
DescriptionNo.
1
2
3
USB 3.0 Port
Front Control Panel
Service/Asset Tag with System Serial Number and
BMC Unique Password
Drive Bay 3Drive Bay Drive Bay Drive Bay Drive Bay Drive Bay 1 5 7 9 11
8 Drive Configuration
12 Drive Configuration
1 2
Drive Bay 0 Drive Bay Drive Bay Drive Bay 6 8 10Drive Bay 2
3
Drive Bay 4
LBL-2508-B-QRG Rev 1.0
# SMC Part NumberDescrip�on
1 NVME CBL-MCIO-1216M5FD1
2 NVME CBL-MCIO-1220M5FD2
3 NVME CBL-MCIO-1244M5FD3
4 NVME CBL-MCIO-1239M5FD4
5 NVME CBL-MCIO-1233M5FF5
6 NVME CBL-MCIO-1225M5FF6
# SMC Part NumberDescrip�on
1 NVME CBL-MCIO-1216M5FD1
2 NVME CBL-MCIO-1220M5FD2
3
# SMC Part NumberDescrip�on
1 NVME CBL-MCIO-1233M5FF5
2 NVME CBL-MCIO-1225M5FF6
NVME CBL-MCIO-1244M5FD3
4
# SMC Part NumberDescrip�on
1 SAS CBL-SAST-1273LP-100
2 SAS CBL-SAST-1262LP-100
# SMC Part NumberDescrip�on
1 SAS CBL-SAST-1273LP-100
# SMC Part NumberDescrip�on
1 SAS CBL-SAST-1262LP-100
NVME CBL-MCIO-1239M5FD4
12 NVMe
CPU1 CPU2 CPU1 CPU2 CPU1 CPU2
8 NVMe
CPU1 CPU2 CPU1 CPU2 CPU1 CPU2
4 NVMe
12 SAS/SATA 8 SAS/SATA 4 SAS/SATA
1
1 2
BPN-NVME5-HS119N-S4RBPN-NVME5-HS119N-S4RBPN-NVME5-HS119N-S8L
3 4
3
BPN-NVME5-HS119N-S8L BPN-NVME5-HS119N-S4RBPN-NVME5-HS119N-S8L BPN-NVME5-HS119N-S8L
AOC-S39xx / AOC-S38xxAOC-S39xx / AOC-S38xxAOC-S39xx / AOC-S38xx
11
1
11
1
1
1
BPN-NVME5-HS119N-S4R
2
2
56
65
2
4
12
21
1
1 2 3 4
3
2
4
3. Put processor heatsink module into MB.1. Put processor into bracket
attention to the lineup Pin and
key on both processor and carrier. Processor Carrier Assembly
2. Put processor carrier module into HS.
T30 Torx
Driver
Use a torque
of 12lbf-in
CPU tSocke
Processor Carrier Assembly (with CPU
mounted on the Processor Clip)
CPU Installation
Storage AOC Drive Bay Cable Routing
System Information
Each system comes with a unique
default password for the ADMIN user.
This can be found on a sticker on the
motherboard and a sticker underneath
the service tag on chassis.
If necessary, the password can be
reset by the Supermicro IPMICFG tool.
For more information, please visit
https://www.supermicro.com/en/solutions/
management-software/bmc-resources
S/N Label
Pull-out tag with BMC
unique password and
Serial Number Label
underneath.
PULL
BMC: XXXXXXXXXXXX
PWD: AMBWODMRG T
S/N: S123456XXX0123
BMC: XXXXXXXXXXXX
PWD: AMBWODMRGT
S/N: S123456XXX0123
A
B
Pin 1
Make sure the lever
is pressed down before
installing the processor.
Pin 1
a
c
b
d
A
C
B
D
Processor Carrier Assembly
(Upside Down)
Thermal grease
A, B, C, D: Peek Nut
1, 2, 3, 4: Rotating Wire
a, b, c, d: Threaded Fastener
Peek Nut
(Unlatched) (Latched)
Rotating Wire
a
c
b
d
C
A
D
B
Rotating Wire 1
Rotating Wire 3
Rotating Wire 4
Rotating Wire 2
Peek Nut
NVMe Drive Bay Cable Routing
Memory Support
DDR5 Memory Population Table for X13DP Motherboards (with 32 DIMMs Installed)
2 CPUs:
(Recommended) Memory Population Sequence
2 CPUs & 2 DIMMs
2 CPUs & 4 DIMMs
CPU1: CPU2: P1-DIMMA1, P2-DIMMA1
CPU1: CPU2:P1-DIMME1, P2-DIMME1
CPU1 CPU2:: P1-DIMMB1, P2-DIMMB1
CPU1: CPU2: P1-DIMMF1, P2-DIMMF1
2 CPUs & 8 DIMMs
CPU1: CPU2: P1-DIMMA1/P1-DIMMG1, P2-DIMMA1/P2-DIMMG1
CPU1: CPU2: P1-DIMMC1/P1-DIMME1, P2-DIMMC1/P2-DIMME1
CPU1: P1-DIMMA1/P1-DIMMC1/P1-DIMME1/P1-DIMMG1
CPU2: P2-DIMMA1/P2-DIMMC1/P2-DIMME1/P2-DIMMG1
2 CPUs & 10 DIMMs CPU1: P1-DIMMA1/P1-DIMMC1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1/P1-DIMMG1
CPU2: P2-DIMMA1/P2-DIMMC1/P2-DIMME1/P2-DIMMG1
2 CPUs & 12 DIMMs
2 CPUs & 16 DIMMs
CPU1: P1-DIMMA1/P1-DIMMC1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1/P1-DIMMG1
CPU2: P2-DIMMA1/P2-DIMMC1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1/P2-DIMMG1
CPU1: P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMME1/P1-DIMMG1/P1-DIMMH1
CPU2: P2-DIMMA1/P2-DIMMB1/P2-DIMMC1/P2-DIMME1/P2-DIMMG1/P2-DIMMH1
CPU1: P1-DIMMB1/P1-DIMMC1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1/P1-DIMMH1
CPU2: P2-DIMMB1/P2-DIMMC1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1/P2-DIMMH1
CPU1: P1-DIMMA1/P1-DIMMB1/P1-DIMMD1/P1-DIMMF1/P1-DIMMG1/P1-DIMMH1
CPU2: P2-DIMMA1/P2-DIMMB1/P2-DIMMD1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1
CPU1: P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1/P1-DIMMG1/P1-DIMMH1
CPU2: P2-DIMMA1/P2-DIMMB1/P2-DIMMC1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1
2 CPUs & 22 DIMMs
2 CPUs & 24 DIMMs
CPU1: P1-DIMMA1/P1-DIMMA2/P1-DIMMB1/P1-DIMMB2/P1-DIMMC1/P1-DIMMC2/P1-DIMMD1/P1-DIMMD2/P1-
DIMME1/P1-DIMME2/P1-DIMMF1/P1-DIMMF2/P1-DIMMG1/P1-DIMMG2/P1-DIMMH1/P1-DIMMH2
CPU2: P2-DIMMA1/P2-DIMMC1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1/P2-DIMMG1
2 CPUs & 32 DIMMs
CPU1: P1-DIMMA1/P1-DIMMA2/P1-DIMMB1/P1-DIMMB2/P1-DIMMC1/P1-DIMMC2/P1-DIMMD1/P1-DIMMD2/P1-
DIMME1/P1-DIMME2/P1-DIMMF1/P1-DIMMF2/P1-DIMMG1/P1-DIMMG2/P1-DIMMH1/P1-DIMMH2
CPU2: P2-DIMMA1/P2-DIMMB1/P2-DIMMC1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1
CPU1: P1-DIMMA1/P1-DIMMA2/P1-DIMMB1/P1-DIMMB2/P1-DIMMC1/P1-DIMMC2/P1-DIMMD1/P1-DIMMD2/P1-
DIMME1/P1-DIMME2/P1-DIMMF1/P1-DIMMF2/P1-DIMMG1/P1-DIMMG2/P1-DIMMH1/P1-DIMMH2
CPU2: P2-DIMMA1/P2-DIMMA2/P2-DIMMB1/P2-DIMMB2/P2-DIMMC1/P2-DIMMC2/P2-DIMMD1/P2-DIMMD2/P2-
DIMME1/P2-DIMME2/P2-DIMMF1/P2-DIMMF2/P2-DIMMG1/P2-DIMMG2/P2-DIMMH1/P2-DIMMH2
Rear View
DescriptionNo.
1
2
3
4
5
6
7
8
Redundant Power Supplies
Dedicated BMC LAN Port
Slot 1, PCI-E 5.0 p1-x16 Slot (CPU2)
Slot 2, PCI-E 5.0 p1-x16 Slot (CPU1)
Slot 3, PCI-E 5.0 p1-x16 Slot (CPU2)
Slot A1, AIOM/OCP 3.0 Networking
Slot (CPU1)
VGA port
2x USB 2.0 Ports
Description
No.
9
Power Supply LED Solid Green
Power Supply LED Blinking Green
Power Supply LED Solid Green
Power Supply LED Blinking Green
A valid power source is connected to the
PSU and the PSU is operational
(Scenario 1) Power source to the PSU is
disconnected or invalid but a second
PSU is operational.
(Scenario 2) PSU failure and the PSU is
not operational.
PSU is in standby state
(12VSB standby power only).
A PSU warning event occurred and the
PSU is still operational.
21 3
9 8 7 6
4 5
Default Setting
Open (Normal)
Jumper
JBT1
Connector
BT1
FAN1 ~ FAN8
JAIOM1
JF3_JIPMB1
JFP1
JFP2
JGPW1~5
JIO1
JL1
JNCSI1
JNVI2C1
JNVVPP1
JPCIE1, JPCIE4
JPCIE2A1, JPCIE2B1,
JPCIE3A1,JPCIE3B1,
JPCIE5A1, JPCIE5B1
JPRG1
JPWR1, JPWR4
JRSI2C1
JS1
JTPM1
JUID1
JUSB3
JVRM1
M.2-H1/M.2-H2
P1_NVME0/P1_
NVME1/P2_
NVME0/P2_NVME1
PSU1~2
Description
CMOS clear
Description
Onboard CMOS battery
6-pin system cooling fan headers
The Supermicro® Advanced I/O Module (AIOM) slot
6-pin BMC external I²C header (for an BMC card)
Front control panel header
Front VGA header
8-pin power connector
Low-profile slimSAS 8x I/O connector
Chassis intrusion header
NC-SI (Network Controller Sideband Interface) connector
NVMe SMBus (I²C) headers used for PCIe hot-plug
SMBus clock and data connections
CPU VPP bus header for backplane NVMe riser card device
CPU PCIe 5.0 p1-x16 slots
CPU PCIe 5.0 p1-x8 slots
Complex Programmable Logical Device (CPLD) header
6-pin power connector
SMBus header for riser card
I-SATA 0~7 connector
Trusted Platform Module/Port 80 Connector
Multi-purpose UID switch and reset switch
USB 3.0 header (supports two USB 3.0 ports)
VRM SMB clock to BMC
M.2 PCIe 3.0 p1-x2 or SATA 3.0 hybrid slots (Supports
M-Key 2280and 22110) supported by PCH
Power supply unit connectors
NVMe PCIe 5.0 p1-x4 ports
P1_PE0 15-0 (JAIOM)
JITP1
X13DEM
REV:1.02A
BAR CODE
BMC CODE
CPU1 CPU2
JPRG1
MH5
MH10
MH4
MH3
MH2
MH12
MH11
FAN8 FAN7 FAN6 FAN5 FAN4 FAN3 FAN2 FAN1
LEDM1
LED1
LEDBMC
JVRM1
JTPM1
JRK1
MH9
MH1
JU B3
JRU1
JL1
JRSI2C1 JNV I2C1 JNVVPP1
JF3_JIPMB 1
JPCIE2B1
JPCIE2A1
JIO1
JPCIE3B1 J PCIE3A1
JPC E5B1 JPCIE5A1
P1_NVME0 P1_NVME1
P1_NVME3
P2_NVME3
P1_NVME2 P2_NVME 0 P2_NVME1
P2_NVME2
PSU2 PS U1
M 2-H2 M.2-H
JBT1
BT1
JFP2
JPCIE1
JPC E4
JAIOM1
JNCSI1
MH16
MH17
MH18
MH19
MH15
JPMW4
JPMW3
JPMW2 JPMW5
JPMW1
JPWR1 JPWR4
JAIOM2SB1
JS1
VROC
RAID Key
JFP1
Front Panel CTRL2
LEDPWR
LED2
P2_PE4 7-0
P1_PE0 15-0
P1-AIOM PCIe 5.0 X16
P2_PE4 8-15
P2 PCIe 5.0 X8
P2 PCIe 5.0 X8
P2 PCIe 5.0 X8
P2_PE3 0-7
P2 PCIe 5.0 X8
P1 PCe 5.0 X8
P1_PE3 8-15
P1 PCIe 5.0 X8
P1 PCIe 5.0 X8
P1_PE3 0-7
P1 PCIe 5.0 X8
P1_PE4 0-7
P2_PE0 0-7
P2 PCIe 5.0 X8
P2_PE0 8-15
P2_PE1 15-0
P2 SLOT2 PCIe5.0 X16
P2 CIe 5.0 X8
P _PE2 8-15
P2 PCIe 5.0 X8
P2_PE2 0-7
BMC LAN/USB /VGA
USB2/3 (3.0)
P1_PE1 7-0
S A 0-7AT
P1_PE1 15-8
P1 PCIe 5.0 X8P1 PCIe 5.0 X8
P1_PE2 15-0
JIPMB 1
P1 SLOT1 PCIe 5.0 X16
UID-LED
TPM/PORT80
P2-DIMMD1
P2-DIMMD2
P2-DIMMC2P2-DIMMC1
P2-DIMMB1
P2-DIMMB2
P2-DIMMA1
P2-DIMMA2
P2-DIMME2
P2-DIMMF2
P2-DIMME1
P2-DIMMF1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P2-DIMMG1
CLEAR
CMOS
P1-DIMMD2
P1-DIMMD1
P1-DIMMC1
P1-DIMMC2
P1-DIMMB1
P1-DIMMB2
P1-DIMMA1
P1-DIMMA2
P1-DIMME1
P1-DIMME2
P1-DIMMF1
P1-DIMMG2
P1-DIMMF2
P1-DIMMH2
P1-DIMMG1
P1-DIMMH1
Battery
UID/System Reset
FP CTRL1
Power Supply Unit 2 Power Supply Unit1
BMC
PCH
P2_PE3 8-15
P1_PE4 8-15
BIOS
Flash_CPLD
FAN10
9NAF
P2
P
PCI-E 5.0 X8
2 PCIe 5.0 X8
JNCSI1
M. 12-H
JPWR4
JVRM1
M.2-H2
JL1
USB2/3
JIO1
SATA0-7
J R1PW
P1_PE2 15-0
P 1 81_PE 15-
JPMW4
BT1
JBT1
P 2 52_PE 8-1
P 2 7 2_PE 0-
P 1 0 2_PE 15-
PS PSU2 U1
JTPM1
JRU1
1BMPIJ
LED2
LED1
P1_PE1 7-0
JFP1
JFP2
1C2ISRJ
JNVI2C1
JNVVPP1
LEDM1
FAN9
FAN10
JITP1
JPRG1
JPMW1
JAIOM2SB1
JPCIE5B1
JPMW2
JPCIE5A1
JPMW5
JPMW3
CPLD BIOS
FAN2
FAN1
P VME0 1_N
FAN8
FAN7
FAN6
P VME31_N
FAN5
P VME21_N
P VME02_N
P VME12_N
FAN4
FAN3
P VME32_N
P VME22_N
P VME11_N


Produkt Specifikationer

Mærke: Supermicro
Kategori: Server
Model: SuperServer SYS-121H-TNR

Har du brug for hjælp?

Hvis du har brug for hjælp til Supermicro SuperServer SYS-121H-TNR stil et spørgsmål nedenfor, og andre brugere vil svare dig




Server Supermicro Manualer

Server Manualer

Nyeste Server Manualer