TCL TAC-12CSD/XAC1 Manual

TCL Aircondition TAC-12CSD/XAC1

Læs nedenfor 📖 manual på dansk for TCL TAC-12CSD/XAC1 (26 sider) i kategorien Aircondition. Denne guide var nyttig for 13 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/26
TCL Air Conditioner Service Manual
1
ON/OFF type air conditioner
Service Manual
Models
TAC-09CSD/XAB1
TAC-12CSD/XAB1
TAC-18CSD/XAB1
TCL Air Conditioner Service Manual
2
CONTENTS
PART  TECHNICALINFORMATION.............................................................................3
1. IMPORTANTNOTICE.............................................................................................................3
2. REFRIGERATIONCYCLEDIAGRAM.............................................................................................4
3. ELECTRICDIAGRAM.............................................................................................................5
3.1Wiringdiagram........................................................................................................5
3.2PCBLAOUT................................................................................................................8
4. ELECTRONICC IONTROLLER NTRODUCTION..............................................................................11
4.1Electroniccontroller................................................................................................11
PART
 INSTALLATIONANDMAINTENANCE..............................................................16
1. NOTESFORINSTALLATIONANDMAINTENANCE.........................................................................16
2INSTALLATION....................................................................................................................24
2.1InstallationDimensionDiagram.............................................................................24
2.2Accessory................................................................................................................25
2.3Position...................................................................................................................26
2.4Electricityandwiring..............................................................................................26
2.5IDUInstallation.......................................................................................................26
2.6ODUInstallation.....................................................................................................29
2.7Vacuumandgasleakagetest.................................................................................30
2.8Finaltest.................................................................................................................30
3. MAINTENANCE.................................................................................................................31
3.1Failurecode............................................................................................................31
3.2Troubleshooting....................................................................................................32
4. DISASSEMBLYIDU & ODU.................................................................................................35
4.1.IDUDisassembly....................................................................................................35
4.2ODUAssembly........................................................................................................39
APPENDIX........................................................................................................................44
Appendix1ThecomparisontableofCelsius‐Fahrenheittemperature.........................44
Appendix2ThePipelengthandGascharging.............................................................45
Appendix3PipesFlaring..............................................................................................46
Appendix4THERMISTORTEMPERATURECHARACTERISTICS.......................................47
TCL Air Conditioner Service Manual
3
Part Technical Information
1. Important Notice
This service manual is intended for use by individuals possessing adequate
backgrounds of electrical, electronic
and mechanical experience. Any
attempt to repair the appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible for the
interpretation of this information, nor can
it assume any liability in
connection with its use.
The information, specifications and parameter are subject to change due to
technical modification or improvement
without any prior notice. The
accurate specifications are presented on the nameplate label.
TCL Air Conditioner Service Manual
4
2. Refrigeration cycle diagram
Cool only
Heating
Liquid side
2-way valve
Gas side
3-way valve
Compressor
4-way valve
Muffler
Muffler
Heat exchange
(Condenser)
Heat exchange
(Evaporator)
Check valve
Cooling
Heating
Capillary
TCL Air Conditioner Service Manual
5
3. Electric Diagram
3.1 Wiring diagram
MODELTAC-09CSD/XAB1
INDO UINT:OR
OUTDOO UINT:R
TCL Air Conditioner Service Manual
6
MODELTAC-12CSD/XAB1
INDOOR UINT:
OUTDOOR UINT:
TCL Air Conditioner Service Manual
7
MODELTAC-18CSD/XAB1
INDOOR UINT:
OUTDOOR UINT:
TCL Air Conditioner Service Manual
8
3.2 PCB LAOUTOnly for reference
Indoor unit
Indoor PCB
7k, 9K, 12K, 18K
A010268
24K
A010270
1 ODU AC power output
2 Fuse
3 Transformer out
4 IDU AC power input
5 AC motor driver
6 IDU/ODU wiring
connection-N connector
7 Power supply-N connector
8 Anion connector
9 IDU/ODU communication
wiring
10 Up-Down swing connector
11 Left-Right swing connector
12 Display
13 Emergency button
14 AC Motor feedback
15 Temperature sensor
connector
16 WIFI connector
1
2
3
4
5 6 7 8 9 10 11 12
13
14
15
16
1ODU AC power output
2Fuse
3ODU AC power input
4DC fan motor connection
5IDU/ODU wiring connection --N
connector
6Power supply --N connector
7Anion connector
8IDU/ODU communication wiring
9Left-Right swing connector
10 Up-Down swing connector
11 Display
12 Emergency button
13 Temperature sensor connection
14 WIFI connection
1
2
3
4 5 6 7 8 9 10 11 12
13
14
TCL Air Conditioner Service Manual
9
7K, 9K, 12K, 18K
Top view
A010235
7K, 9K, 12K, 18K24K
Top view
A010254
1 ODUACpoweroutput
2 Fuse
3 ODUACpowerinput
4 ACmotordriver
5 IDU/ODUwiringconnection‐N
connector
6 Powersupply‐Nconnector
7 Left‐Rightswingconnector
8 Up‐Downswingconnector
9 ACMotorfeedback
10 Display
11 Emergencybutton
12 Temperaturesensorconnector
13 TransformerIN
14 TransformerOUT
15 Anionconnrctor
1 TransformerIN
2 ODUACpoweroutput
3 Fuse
4 ODUACpowerinput
5 ACmotordriver
6 IDU/ODUwiring
connection‐Nconnector
7 Powersupply‐Nconnector
8 Left‐Rightswingconnector
9 Up‐Downswingconnector
10 ACMotorfeedback
11 Display
12 Emergencybutton
13 Temperaturesensor
connector
14 WIFIconnection
15 TransformerOUT
16 Anionconnrctor
TCL Air Conditioner Service Manual
10
7K, 9K, 12K, 18K24K
Top view
A010422
1 TransformerIN
2 ODUACpoweroutput
3 Fuse
4 ODUACpowerinput
5 ACmotordriver
6 IDU/ODUwiring
connection‐Nconnector
7 Powersupply‐N
connector
8 Left‐Rightswing
connector
9 Up‐Downswing
connector
10 ACMotorfeedback
11 Emergencybutton
12 Temperaturesensor
connector
13 WIFIconnection
14 Display
15 TransformerOUT
16 Anionconnrctor
TCL Air Conditioner Service Manual
11
4. Electronic Controller Introduction
4.1 Electronic controller
RT-------Room Temperature.
IPT------Indoor Pipe (Coil) Temperature.
ST------Indoor Setting Temperature.
OPT--- Outdoor Pipe Temperature.
CRT--- Compensated Room Temperature.
IDU--- Indoor unit
ODU--- Outdoor unit.
Note: When AC finishing installation, because of the air ventilation and the distance of temperature test sensor to
different location of the house, the temperature for IDU PCB control need compensation.
1
. Cooling mode. CRT=RT;
2
. Heating mode. CRT=RT-3
----- Split AC.
4.1.1 Auto mode
5.2.1.1. The set temperature can be adjusted from 16-31 (61-88) on auto mode, the operation of fan speed and
vane position according to preset.
5.2.1.2. Operation
When unit set to auto mode, it will work on cooling, heating or fan mode totally according to Δt --the temperature
difference between RT and ST shown as table:
Mode Δt=RT-ST
COOLING Δt >1
FAN -1Δt≤ 1
HEATING Δt <-1
4.1.2 Cooling mode
4.1.2.1. Temperature control :16-31(61-88), and the operation of fan speed and vane position according to preset.
4.1.2.2. Compressor and process control
1). When RT-ST≥1 the compressor starts up working, AC operates as customer preset;
2). When:
a. RT-ST≥1, the compressor will start up operation once it stops 3 minutes, and unit without any o ther
protection or failure code.
b. RT-ST≤-1, the compressor will stop working while it works for 6 minutes or more continuously.
c. -1RT-ST1, the compressor keeps original state.
3). The compressor will also stop working while unit:
a. switched off.
b. under protection.
c. changed to fan mode.
4). Under normal operation, the compressor can be stopped by program until it works for 6 min at least once starts
up.
5). In the process of unit operation, once the compressor ceased, it should be 3 min delay for the next procedure.
4.1.2.3. ODU Fan motor control:
1). While unit:
a. switched off.
b. under protection.
c. to the set temperature.
The compressor stops working, and the fan motor will stop operation after 50s delay.
TCL Air Conditioner Service Manual
12
2). When switch on unit on cooling mode, ODU fan motor will delay 5s after compressor starts up.
4.1.2.4. When ODU failure or stops for protection, IDU works as preset.
4.1.2.5. Anti-frosting protection
While condition a), b) matched, the AC unit transferred to anti-frosting protection.
a). After the compressor continual works for 6 minutes, and tested IPT≤0 for 3 minutes continuously.
b). After the compressor continual works 6 minutes, and tested IPT-2 for 3 seconds continuously.
c). AC unit quit protection while IPT≥10.
4.1.3 Dry mode
4.1.3.1. Temperature control: 16~31.
Fan speed: low
Vane blade position: as customer preset
4.1.3.2. When ODU failure or stops for protection, IDU works as preset.
4.1.3.3. Compressor and process control
1). When RT-ST≥1, the compressor starts up working, AC operates as customer preset;
2). When
a. RT-ST2, the compressor will start up operation once it stops 3 minutes, and unit without any o ther
protection or failure code.
b. RT-ST-2, the compressor will stop working while it works 6 minutes or more continuously.
c. -2≤RT-ST≤ 2the compressor will stop working while it works for 6 minutes, after 4 minutes it will start
working again.
3). The compressor will also stop working while unit:
a. switched off.
b. under protection.
c. changed to fan mode.
4). Under normal operation, the compressor can be stopped by program until it works for 6 min at least once starts
up.
5). In the process of unit operation, once the compressor ceased, it should be 3 min delay for the next procedure.
4.1.3.4. ECO and sleep mode: Invalid.
4.1.3.5. Anti-frosting protection
While any of condition a), b), or c) matched, the AC unit transferred to anti-frosting protection.
a). After the compressor continual works for 6 minutes, and tested IPT≤0 for 3 minutes continuously.
b). After the compressor continual works 6 minutes, and tested IPT≤-2 for 3 seconds continuously.
c). If the unit works as 6 minutes ON, 4 minutes OFF, and tested IPT≤0 for 3 minutes continuously.
d). AC unit quit protection while IPT≥10.
4.1.4 Heating mode
4.1.4.1. Temperature control: 16-31.
4.1.4.2. Compressor and process control.
1). When ST-CRT≥1 ng, AC operates as customer pre, the compressor starts up worki set;
2). When
a. ST-CRT≥1, the compressor will start up operation once it stops 3 minutes, and unit without any other
protection or failure code.
b. ST-CRT≤-1the compressor will stop working while it works 6 minutes or more continuously .
c. -1ST-CRT1the compressor keeps original state.
3). The compressor will also stop working while unit:
a. switched off.
b. under protection.


Produkt Specifikationer

Mærke: TCL
Kategori: Aircondition
Model: TAC-12CSD/XAC1

Har du brug for hjælp?

Hvis du har brug for hjælp til TCL TAC-12CSD/XAC1 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Aircondition TCL Manualer

TCL

TCL TAC-12CHSD-XA82 Manual

4 December 2024
TCL

TCL TAC-12CHSD/TPG11IT Manual

11 September 2024
TCL

TCL TAC-09CHSD/TPG11IT Manual

11 September 2024
TCL

TCL TAC-12CHSD Manual

6 September 2024
TCL

TCL TAC-12CHSD/TPG11I Manual

3 September 2024
TCL

TCL TAC-28CHSD Manual

3 September 2024
TCL

TCL TAC-24CHSD Manual

3 September 2024
TCL

TCL TAC-18CHSD Manual

3 September 2024

Aircondition Manualer

Nyeste Aircondition Manualer

Daitsu

Daitsu AUD-30K-DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 36K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 48K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 60TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 42K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 48TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 36TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 18K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 24K DB Manual

28 Februar 2025