TP-Link Omada EAP773 Manual
TP-Link
Adgangspunkt
Omada EAP773
Læs nedenfor 📖 manual på dansk for TP-Link Omada EAP773 (2 sider) i kategorien Adgangspunkt. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
Quick Installation Guide
Wireless Access Point
Note: EAP650 is used as an example throughout the Guide. Images may dier from your actual product.
Hardware Overview
1
RESET
With the device powered on, press and hold the button for about 5 seconds until the LED flashes quickly. Then
release the button. The device will restore to factory default settings.
Ethernet Port: ETH (PoE)
The port is used to connect to a router or a switch to transmit data, or to a PSE (Power Sourcing Equipment),
such as a PoE switch, for both data transmission and Power over Ethernet (PoE) through Ethernet cable.
Note: For EAPs with 10Gbps port, if you use a CAT5E cable, the 10Gbps link of the Ethernet port is less than 55m. To achieve a longer
transmission distance, use a shielded CAT6A cable.
Power Port
Plug one end of the power adapter to this port and the other end to a standard electrical wall outlet to power the
EAP.
Note: Power adapter is not included in the package contents of certain models. For details, refer to the product specications or
datasheet. For power supply specications, refer to the product label.
Self-tapping ScrewsPlastic Wall Anchors
1
Remove the ceiling tile.
Note: Make sure that the ceiling tile is larger than the EAP.
Wing NutsWashers Pan-head Screws
The EAP can be mounted to the ceiling, the wall, or in a junction box, using the screws in the
package. Choose the appropriate mounting and installation steps below.
Note: This product requires heat dissipation through the metal bracket during use, please be
careful not to touch the metal bracket in the heat dissipation.
Hardware Installation
2
2
Insert the plastic wall anchors into the holes.
Front Panel
Rear Panel
Option 1: Ceiling Mounting
Option 2: Wall Mounting
5
Connect the Ethernet cable to the Ethernet port.
Please pay attention to the triangle sign. Attach
the EAP to the mounting bracket, then rotate it
until it locks into place, as shown on the left.
2
Place the mounting bracket in the center of the
ceiling tile. Mark positions for the screw holes
and a location for the Ethernet cable hole.
Drill holes for the screws and a hole for the
Ethernet cable at the marked positions.
3
Secure the mounting bracket to the ceiling tile
using pan-head screws, washers, and wing nuts,
as shown on the left.
5
Attach the EAP to the mounting bracket by
rotating it until it locks into place, as shown on
the left.
2
Connect the Ethernet cable to the Ethernet
port on the EAP.
3
Attach the EAP to the mounting bracket by
rotating it until it locks into place, as shown on
the left.
Setup with videos
Visit https://www.tp-link.com/support/setup-video/ or scan the QR code
to search for the setup video of your product model.
4
Feed the Ethernet cable through the hole and
set the ceiling tile back into place.
3
Secure the mounting bracket to the wall by
driving the self-tapping screws into the
anchors. Make sure that the shoulders of the
mounting bracket are on the outside.
1
If your Ethernet cable feeds through the wall,
position the mounting bracket below the cable
hole. Mark positions for the screw holes and
drill holes at the marked positions.
Φ 7.6 mm (19/64 in)
Option 2: Wall MountingOption 1: Ceiling Mounting Option 3: Junction Box Mounting
Blue On:
Working normally/Initializing. For EAPs with dual-color LED: Normal power supply
Orange On:
For EAPs with dual-color LED: Low power supply
Flash: • Flash twice:
Initialization is completed.
• Flash quickly:
The EAP is resetting, or the Omada controller is locating the device*.
• Flash once per second:
The EAP is upgrading.
• Flash Slowly:
The EAP is in the isolated state.
LED Indicator
Off:
Working abnormally/Power o/LED is turned o.
* When the Locate feature is activated in the Omada controller, the LED ashes quickly to locate and identify the
device. The LED will ash for 10 minutes. You can disable the feature manually to stop it from ashing.
Option 3: Junction Box Mounting
Prepare the cables and the junction box in advance. Ensure that the mounting holes align
to your junction box.
Route the cables through the square cable
hole on the mounting bracket, and secure the
mounting bracket to the junction box using
screws.
1
The EAP can be powered via a power adapter or a PSE device (such as a PoE switch) which
complies with Power Source Class 2 ( PS2) or Limited Power Source (LPS) of IEC 62368-1.
Option 1: Via PoE Switch
Option 2: Via Power Adapter
Plug one end of the power adapter into the power port of the EAP and the other end to a
standard electrical wall outlet.
Note: Power adapter is not included in the package contents of certain models. For details, refer to the product specications or
datasheet. For power supply specications, refer to the product label.
Power Supply
3
Switch
Power Adapter
PoE Switch
Connect an Ethernet cable from the PoE switch to the Ethernet port.
Note: For PoE power supply specications, refer to the product label.
*Compatible wall junctions:
©2023 TP-Link 7106510781 REV1.5.1
4
Connect the Ethernet cable to the Ethernet
port on the EAP.
Φ 25 mm (63/64 in)
Φ 4 mm (5/32 in)
Produkt Specifikationer
Mærke: | TP-Link |
Kategori: | Adgangspunkt |
Model: | Omada EAP773 |
Har du brug for hjælp?
Hvis du har brug for hjælp til TP-Link Omada EAP773 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Adgangspunkt TP-Link Manualer
3 Oktober 2024
1 Oktober 2024
11 September 2024
10 September 2024
10 September 2024
2 September 2024
2 September 2024
1 September 2024
1 September 2024
1 September 2024
Adgangspunkt Manualer
- Adgangspunkt Bosch
- Adgangspunkt Aruba
- Adgangspunkt Netis
- Adgangspunkt Moog
- Adgangspunkt HP
- Adgangspunkt D-Link
- Adgangspunkt Asus
- Adgangspunkt AVM
- Adgangspunkt Planet
- Adgangspunkt Belkin
- Adgangspunkt Edimax
- Adgangspunkt Black Box
- Adgangspunkt DataVideo
- Adgangspunkt TRENDnet
- Adgangspunkt Honeywell
- Adgangspunkt Buffalo
- Adgangspunkt Linksys
- Adgangspunkt Cisco
- Adgangspunkt Huawei
- Adgangspunkt Netgear
- Adgangspunkt Totolink
- Adgangspunkt Digitus
- Adgangspunkt Zebra
- Adgangspunkt Techly
- Adgangspunkt Dell
- Adgangspunkt Alcatel-Lucent
- Adgangspunkt LevelOne
- Adgangspunkt ZyXEL
- Adgangspunkt Fortinet
- Adgangspunkt Tenda
- Adgangspunkt LigoWave
- Adgangspunkt EQ3
- Adgangspunkt Ubiquiti Networks
- Adgangspunkt EnGenius
- Adgangspunkt Devolo
- Adgangspunkt Grandstream
- Adgangspunkt Renkforce
- Adgangspunkt Mikrotik
- Adgangspunkt Eminent
- Adgangspunkt Hercules
- Adgangspunkt V7
- Adgangspunkt Amer Networks
- Adgangspunkt Mercku
- Adgangspunkt Dahua Technology
- Adgangspunkt Speco Technologies
- Adgangspunkt StarTech.com
- Adgangspunkt Draytek
- Adgangspunkt Crestron
- Adgangspunkt Lindy
- Adgangspunkt Lancom
- Adgangspunkt Sitecom
- Adgangspunkt AMX
- Adgangspunkt Homematic IP
- Adgangspunkt Intellinet
- Adgangspunkt Kingston
- Adgangspunkt Steren
- Adgangspunkt Media-Tech
- Adgangspunkt Moxa
- Adgangspunkt Allnet
- Adgangspunkt Allied Telesis
- Adgangspunkt Airlive
- Adgangspunkt Macally
- Adgangspunkt Hawking Technologies
- Adgangspunkt INCA
- Adgangspunkt Advantech
- Adgangspunkt Silex
- Adgangspunkt SMC
- Adgangspunkt Cambium Networks
- Adgangspunkt CradlePoint
- Adgangspunkt FlyingVoice
- Adgangspunkt Extreme Networks
- Adgangspunkt Aerohive
- Adgangspunkt Bountiful
- Adgangspunkt WatchGuard
- Adgangspunkt NUVO
- Adgangspunkt Cudy
- Adgangspunkt IP-COM
- Adgangspunkt Mach Power
- Adgangspunkt Syscom
- Adgangspunkt Meru
- Adgangspunkt Amped Wireless
- Adgangspunkt 3Com
- Adgangspunkt Ruckus Wireless
- Adgangspunkt Bintec-elmeg
- Adgangspunkt Brocade
- Adgangspunkt ICC
- Adgangspunkt Insteon
- Adgangspunkt Juniper
- Adgangspunkt Comtrend
- Adgangspunkt Premiertek
- Adgangspunkt Atlantis Land
- Adgangspunkt Mojo
- Adgangspunkt Luxul
Nyeste Adgangspunkt Manualer
20 November 2024
13 Oktober 2024
9 Oktober 2024
7 Oktober 2024
30 September 2024
30 September 2024
29 September 2024
27 September 2024
27 September 2024
27 September 2024