These models connect to an In-Line, Roof or Wall-
Mounted Remote Blower (sold separately). The blower
used determines the CFM. The Trade-Wind In-Line
blowers are either 836 CFM or 1266 CFM.
Before beginning installation, please thoroughly read and
become familiar with these instructions. Installation and
service must be completed by a qualified installer. Failure to
properly install this product may void the warranty.
VSL430BF
VSL436BF
VSL436-0-19BF
VSL436-0-22BF
VSL442BF
VSL442-0-19BF
VSL442-0-22BF
VSL448BF
VSL448-0-19BF
VSL448-0-22BF
VSL454BF
VSL454-0-19BF
VSL454-0-22BF
VSL460BF
VSL460-0-19BF
VSL460-0-22BF
VSL472BF
VSL472-0-19BF
VSL472-0-22BF
18"
18"
19 ¼"
22
18"
19 ¼"
22"
18"
19 ¼"
22"
18"
19 ¼"
22"
18"
19 ¼"
22"
18"
19 ¼"
22"
28 ⅜"
34 ⅜"
34 ⅜"
34 ⅜"
40 ⅜"
40 ⅜"
40 ⅜"
46 ⅜"
46 ⅜"
46 ⅜"
52 ⅜"
52 ⅜"
52 ⅜"
58 ⅜"
58 ⅜"
58 ⅜"
70 ⅜"
70 ⅜"
70 ⅜"
MODEL
FRONT TO
BACK WIDTH CFM
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
PERFORMANCE QUALITY CUSTOMER SERVICE· · REVISED: JANUARY 1, 2024
I N S T A L L A T I O N I N S T R U C T I O N S
U S E & C A R E G U I D E
V S L 4 0 0 S E R I E S
F O R R E M O T E / I N - L I N E B L O W E R S
Installer:
Owner:
Please leave Installation Instructions with the range hood liner.
Please keep Installation Instructions for local electrical inspector’s use and for future reference.
WARNINGS:
IMPORTANT:
TIPS:
Must be followed carefully to avoid personal injury.
Must be followed carefully to avoid damage and incorrect installation.
Contains helpful information to facilitate installation.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the
manufacturer at the address or telephone number listed in the warranty.
b) Before servicing or cleaning unit, switch power off at service panel, lock service panel, and lock the service
disconnection means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
READ AND SAVE THESE INSTRUCTIONS
WARNING! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
© 2 0 2 3 T R A D E - W I N D M A N U F A C T U R I N G , L L C
P R O V E R B S 2 2 : 2 9 1


Produkt Specifikationer

Mærke: Trade-Wind
Kategori: Emhætte
Model: VSL430BF

Har du brug for hjælp?

Hvis du har brug for hjælp til Trade-Wind VSL430BF stil et spørgsmål nedenfor, og andre brugere vil svare dig




Emhætte Trade-Wind Manualer

Trade-Wind

Trade-Wind VSL4541219RC Manual

30 September 2024
Trade-Wind

Trade-Wind T7248 Manual

30 September 2024
Trade-Wind

Trade-Wind VSL430BF Manual

30 September 2024
Trade-Wind

Trade-Wind I32362RC Manual

30 September 2024
Trade-Wind

Trade-Wind T7242-12 Manual

30 September 2024
Trade-Wind

Trade-Wind T7236 Manual

30 September 2024
Trade-Wind

Trade-Wind I32363RC Manual

30 September 2024
Trade-Wind

Trade-Wind T7242 Manual

30 September 2024
Trade-Wind

Trade-Wind T7248-12 Manual

30 September 2024

Emhætte Manualer

Nyeste Emhætte Manualer