Uni-T UT118B Manual

Uni-T Multimeter UT118B

Læs nedenfor 📖 manual på dansk for Uni-T UT118B (2 sider) i kategorien Multimeter. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Measurement Operation
Before measurement, anticlockwise circumgyrate the
red cover and rock the input terminal.
When all themeasurement has been completed,
deasil circumgyrate the red cover then hide the input
terminal. (see gure 3)
Figure 3
1. AC / DC Voltage auto Measurement.
Warning
To avoid harm to the Meter, never input higher than
300V voltage although it is possible to measure
higher voltage.
To measure Voltage, connect the Meter as follows:
● Set the switch to V .
Auto measuremeng mode is a default. Under this
mode can measure AC voltage and DC voltage.
● Connect the test leads across with the object
being measured. The measured value shows on
the display.
● When voltage measurement has been completed,
disconnect the connection between the testing
leads and the circuit under test, and remove the
testing leads away from the input terminal of the
meter.
Note:
The threshold voltage of AC voltage is around 400mV.
2. DC Voltage Measurement
Warning
To avoid harm to the Meter, never input higher than
300V voltage although it is possible to measure
higher voltage.
● Set the switch to V .
● Press SELECT to select DC voltage measurement
mode.
● Connect the test leads across with the object
being measured. The measured value shows on
the display.
● When voltage measurement has been completed,
disconnect the connection between the testing
leads and the circuit under test, and remove the
testing leads away from the input terminal of the
meter.
International Electrical Symbols
Deciency of Built-In Battery
Grounding
AC (Alternative Current)
DC (Direct Current)
Double Insulated
Continuity Test
AC or DC
Diode
Conforms to Standards of European
Warning. Refer to the Operating Manual
The Meter Structure (see gure 1)
1. Front Housing 2. Functional buttons
3. Switch 4. LCD Display
5. Input Terminals
Display Symbols (see gure 2)
Figure 2
1. Indicates auto scan mode
2. High voltage indicator
3 Data hold is active
4. Indicates negative reading
5. The meter is in the autorange mode
6. Indicator for AC voltage
7. Indicator for DC voltage
8. The battery is low
Warning: To avoid false readings, which could
lead to possible electric shock or personal injury,
replace the battery as soon as the battery indicator
appears.
9. Minimum reading.
10. Maximum reading.
11. The unit of Capacitance
12 Test of diode
13. The continuity buzzer is on.
14. V : Volts. The unit of voltage.
mV : Millivolt. 1x10 or 0.001 volts.
15. Ω: Ohm. The unit of resistance
kΩ : kilohm. 1x10 or 1000 ohms.
MΩ: Megaohm. 1x10 or 1,000,000 ohms
Button function and auto power off
1.SELECT
Press to switch between resistance, AC/DC SELECT
voltage, continuity buzzer and diode measurement
modes. Press and hold more than 2 seconds in or
exit “sleep” mode.
UT118A/B Operating Manual
Pen Type Meters
UT118A/B
Operating Manual
Overview
This Operating Manual covers information on safety
and cautions. Please read the relevant information
carefully and observe all the Warnings and Notes
strictly.
Warning
To avoid electric shock or personal injury, read the
"Safety Information" and "Rules for Safe Operation"
carefully before using the Meter.
The Model UT118A and UT118B (hereafter referred
to as “the Meter”) are 3000 counts pen type digits
millimeters. The Meter uses large scale of integrated
circuit with professional multimeter IC as its core and
has full range overload protection.
The Meter measures or tests the following:
AC/DC voltage
● EF Function (UT118B only)
● Resistance
● Diode
● Continuity
● Capacitance
Unpacking Inspection
Open the package case and take out the Meter.
Check the following ite ms carefully to see any
missing or damaged part:
Item Description Qty
1 English Operating Manual 1 piece
2 Test Lead 1 pair
In the event you nd any missing or damage, please
contact your dealer immediately.
Safety Information
This Meter complies with standards EN61010: in
pollution degree 2, over voltage category (CATIII
300V) and double insulation.
CATIII: Distribution level, fixed installation, with
smaller transient over voltages than CAT IV.
Use the Meter only as specified in this operating
manual, otherwise the protection provided by the
Meter may be impaired.
In this manual, a Warning ide ntifies con ditions
and actions that pose hazards to the user, or may
damage the Meter or the equipment under test.
A Note identies the information that user should pay
attention on.
Rules For Safe Operation
Warning
To avoid possible electric shock or personal injury,
and to avoid possible damage to the Meter or to the
equipment under test, adhere to the following rules:
Before using the Meter inspect the case. Do not
use the Meter if it is damaged or the case (or part
of the case) is removed. Look for cracks or missing
plastic. Pay attention to the insulation around the
connectors.
Inspect the test leads for damaged insulation or
exposed metal. Check the test leads for continuity.
Replace damaged test leads with identical model
number or electrical specifications before using the
Meter.
When using the test leads, keep your fingers
behind the nger guards.
Do not apply more than the rated voltage, as
marked on the Meter, between the terminals or
between any terminal and grounding.
When the Meter working at an effective voltage
over 60V DC or 30V AC, special care should be
taken for there is danger of electric shock.
Use the proper function, and range for your
measurements.
Disconnect circuit power and discharge all high
voltage capacitors before testing current, resistance,
diodes or continuity.
Repl ace the b attery as soon as the battery
indicator appears. With a low battery, the Meter
might produce false readings that can lead to electric
shock and personal injury.
When ser vicing th e M e te r, u se only th e
same model or identical electrical specifications
replacement parts.
The internal circuit of the Meter shall not be
altered at will to avoid damage of the Meter and any
accident.
Soft cloth and mild detergent should be used to
clean the surface of the Meter when servicing. No
abrasive and solvent should be used to prevent the
surface of the Meter from corrosion, damage and
accident.
Do not use or store the Meter in an environment
of high temperature, humidity, explosive, inammable
and strong magnetic field. The performance of the
Meter may deteriorate after dampened.
Figure 1
2. HOLD
Press HOLD to enter and exit hold mode (except
under auto scan mode).
Press and hold the HOLD button more t han 2
seconds, the meter automatically holds the value
which obtains at 6 seconds later, at this time, is
displayed and ickering.
If enter “sleep” mode under hold mode, the meter still
in the hold mode when it be turned on.
3. MAX/MIN
The MAX /MIN mode stores minimum (MIN) and
maximum (MAX) input values (except under auto scan
mode). Manual ranging comes when you select this
function.
Press button MAX MIN MAX/MIN MAX/MIN
and vice versa.
Under hold mode and max/min mode, should exit hold
mode rst then press and hold MAX/MIN more than 1
second to exit max/min mode.
4.
Display Backlight and test lead light button, Press
once to turn the display backlight and test lead light
on and press again to turn the display backlight and
test lead light off. It will automatically off after around
1 minute.
5. AUTO POWER OFF
To preserve battery life, the Meter automatically goes
into a “sleep” mode if you do not press any button for
around 10 minutes. The Meter can be activated by
pressing any button, then returns to the display for the
function selected previously
6. BUZZER
The buzzer phonate go with every time button be
effectual pressed. When the meter will auto power off
in 20 seconds the buzzer beeps three times. Before
power off there will be a long time buzzer beeps.
-3
3
6


Produkt Specifikationer

Mærke: Uni-T
Kategori: Multimeter
Model: UT118B

Har du brug for hjælp?

Hvis du har brug for hjælp til Uni-T UT118B stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Uni-T Manualer

Uni-T

Uni-T UT121A Manual

3 September 2024
Uni-T

Uni-T UT122 Manual

3 September 2024
Uni-T

Uni-T UT118C Manual

3 September 2024
Uni-T

Uni-T UT892 Manual

31 August 2024
Uni-T

Uni-T UT89XE Manual

31 August 2024
Uni-T

Uni-T UT171C Manual

31 August 2024
Uni-T

Uni-T UT120B Manual

31 August 2024
Uni-T

Uni-T UT61E Manual

31 August 2024
Uni-T

Uni-T UT139S Manual

31 August 2024
Uni-T

Uni-T UT133B Manual

31 August 2024

Multimeter Manualer

Nyeste Multimeter Manualer

Owon

Owon HDS100 Manual

21 December 2024
Owon

Owon 1000A Manual

18 December 2024
IWH

IWH 73556 Manual

16 December 2024
Vimar

Vimar 20433.N Manual

15 December 2024
Vimar

Vimar 19433.M Manual

15 December 2024
Vimar

Vimar 14433.SL Manual

15 December 2024
Kyoritsu

Kyoritsu KEW-2046R Manual

14 December 2024
Kyoritsu

Kyoritsu KEW 6010B Manual

14 December 2024
Sanwa

Sanwa ACS101 Manual

8 December 2024