Measurement Operation
First check on 9V battery, then turn rotary switch to
the measuring position. If the low battery, “ ” sign.
will be displayed on LCD panel. Nearly to “ ” sign
on the meter front panel terminal input which alarm
not exceed the testing voltage and current input value
limitation.
A. DC/ AC Voltage Measurement (See figure 1)
figur 1e
1. In each range, the meter has an input impedance
of This loading effect can cause measurement 10MΩ.
err or s in high impedance circuits. If the circuit
impedance is less than or equal to the error is 10kΩ,
negligible (0.1% or less).
2. Press SELECT to switch AC or DC voltage
measurement.
3. The display value of AC measurement is effective
value of sine wave( average value).
4. The mV AC range can obtain only under 400
manual mode.
Note:
To avoid possibly damages to the meter, please do
not attempt to input higher than 500V.
To avoid electrical shock, please pay attention during
the high voltage measurement.
B. Capacitor Measurement (UT136B only, figure 2).
figure 2
1 M. The eter will display a xed value as below which fi
is the eter internal fixed distributed capacitance M
value. To ensure accuracy when measuring a small
value of capacitance, the tested value must subtract
this value, REL mode can help on that.
2. It is normal to take several seconds to obtain a
stable reading when testing a high value capacitor.
3. To avoid possibly damages to the meter, please do
not attempt to input higher than DC and 33V rms 60V
AC.
7. attery in meter: 9V F22 or NEDA 4 or B 6 160
IEC6LR61
8. Deficiency of Built in Battery: LCD display “ ”.
9. Product size: 72mm×137mm×35mm
10. Net Weight: About 200g (battery include)
11. Conform: CE
Button function and auto power off
1. HOLD button
Press HOLD to enter and exit hold mode in any mode
except frequency measurement.
2. buttonSELECT
Press bu tton to select th e alternate SEL ECT
functions including AC/DC voltage, AC/DC current,
auto and manual ranging, frequency and duty cycle.
Used as REL function button under resistance
measurement.
3. AUTO POWER OFF
To preserve battery life, the automatically goes Meter
into a “sleep” mode if you do not press any button for
around 5 minutes. The eter can be activated by 1 M
pressing any button, then returns to the display for
the function selected previously. To disable the sleep
mode function, press SELECT button while turning on
the meter.
4. BUZZER
The buzzer phonate go with every time button be
effectual pressed. When the meter will auto power off
in minutes the buzzer beeps 5 times. power 1 Before
off there will be a long time buzzer beeps.
UT136A/B/C/D Operating Manual
UT136A/B/C/D
Handheld Digital Multimeter
Operating Manual
Safety Information
M 136A/Beter UT /C/D complies with the standard
IEC/EN , in pollution degree 2, overvoltage 61010-1
category (CAT II V and double insulation. Use 600 )
the meter only as in this operating manual, specified
otherwise the protection provided by the meter may
be impaired.
1 B. efore using the meter inspect the case. Do not
use the meter if it is damaged or the case (or part
of the is removed. Look for cracks or missing case)
plastic. Pay attention to the insulation around the
connections.
2. Inspect the test leads for damaged insulation or
exposed metal. Replace damaged test leads with
identical model number or electrical specifications
before using the meter.
3. Replace the battery as soon as the battery
indicator “ ” Appears. With a low battery, the
meter might produce false readings that can lead to
electric shock and personal injury.
4. When measurement is on / off against the correct
testing position.
5. Do not apply more that the rated voltage, as
marked on the meter in order to avoid possible
electric shock or personal injury and avoid possible
damage to the meter.
6. Do not change the measuring range during the
testing as it causes to damage the meter.
7. When each measurement has been completed,
disconnect between the test leads and the circuit
under test connection, then turn the meter power
off and remove the test leads away form the input
terminals of the meter.
8. When the meter working at an effective voltage
over V in DC and 3 Vrms in AC, special care 60 0
should be taken.
9. Do not use or store the meter in an environment of
high temperature and humidity. The performance of
the meter may deteriorate after dampened.
10. The internal circuit of the meter shall not be
altered at will to avoid damage of the meter and any
accident.
11. Soft cloth and mild detergent should be used to
clean the surface of the meter when servicing. No
abrasive and solvent should be used to prevent the
surface of the meter from corrosion, damage and
accident.
International Electrical Symbols
Double Insulated
Grounding
Deficiency of Built in Battery
Warning: Refer to the Operating Manual
AC (Alternating Current)
DC (Direct Current)
Conforms to Standards of European Union
Overall Specification
1 M. aximum voltage between any terminals and
grounding. Refer to different range input protection
voltage.
2. A terminal: A H Fast Type Ceramic Fuse 10 10 250V
Φ5x20mm.
3. mA terminal: .5 A H V Fast Type Ceramic 0 250
Fuse Φ5x20mm.
4. Maximum display 4000.
Operating temperature: 0
℃~40℃(32℉~104℉)
Relative Humidity
:0℃~30℃ below≤75%,
30℃~ 40℃≤50%
Storing temperature:-10
℃~50 ℃
(14℉~122℉)
5. Electromagnetism:
Under V/m emission: est Total Accuracy= Spec c 1 B ifi
Accuracy + Measurement 5%.
Over 1V/m emission do not have any specific index
6. Elevation
: 0~
2000m
C. DC/AC Current Measurement (see figure 3)
figure 3
1.Press SELECT to switch AC or DC current measurement
2.Turn off power to the circuit before the connection
between the test leads across with the object being
measured.
3. Selecting the correct terminal input and turn the
rotary switch to select the measuring function. In case
of no any idea on the value input of the current, just
simply test from the high value to low one.
4. Fuses are located on mA and A terminal input. 10
Never attempt the test lead connect to any circuits
especially on the power supply terminal and may be
hurt.
5. For the safety purpose, less than seconds is 10
for each measurement duration and keep minutes 15
duration for next measurement during the current
measurement over 5A.
D. Resistance Measurement (see figure 4)
figure 4
1 -. The LCD displays “OL” indicating open circuit for
the tested resistor or the resistor value is higher than
the maximum range of the meter.
2. To maintain the resistance measurement accuracy,
discount circuit power and discharge all the high
voltage capacitors during the measuring resistance.
3. The test leads cause . ~ .2 resis tance 0 1Ω 0 Ω
variation during the measurement, In order to obtain
precision readings in istance measurement. low-res
Need to make the short circuit on the test leads and
mark the measurement value which show on LCD
display. Then deduct this variation value on the
measurement value which come the meter.
4. If reading with shortened test leads is not less Ω
than or equal to .5 , check for loose test leads, 0 Ω
incorrect function selection or others.
5. For sistance high-re measurement greater than
1MΩ, it is normal to take several seconds to obtain a
stable reading with short test leads for measurement.
6. 60V 30V Do not input higher than DC and AC rms
voltage to prevent any damage and accident.
E. Diodes Measurement (see figure 5)
figure 5
1. Disconnect circuit power and discharge all the high
voltage capacitors before measuring resistance.
2. Place the red test lead on the component’s anode
and place the back test lead on the component’s
cathode, a good diode should still produce a forward
voltage drop reading of ~ mV. The LCD 500 800
displays “OL” indicating circuit for the tested open-
diodes or the testing the diodes with polarity.
3. V. The open circuit for diodes is 1.5
4. Do not input higher than DC and AC rms 60V 30V
voltage to prevent any damage and accident.
F. Continuity Measurement (see figure 6)
Produkt Specifikationer
Mærke: | Uni-T |
Kategori: | Multimeter |
Model: | UT136D |
Har du brug for hjælp?
Hvis du har brug for hjælp til Uni-T UT136D stil et spørgsmål nedenfor, og andre brugere vil svare dig
Multimeter Uni-T Manualer
3 September 2024
3 September 2024
3 September 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
Multimeter Manualer
- Multimeter Bosch
- Multimeter Hager
- Multimeter Owon
- Multimeter Extech
- Multimeter Silverline
- Multimeter Emos
- Multimeter Metrix
- Multimeter TFA
- Multimeter Pyle
- Multimeter Biltema
- Multimeter Abus
- Multimeter Keithley
- Multimeter Hama
- Multimeter Milwaukee
- Multimeter BENNING
- Multimeter Clas Ohlson
- Multimeter Metrel
- Multimeter Kyoritsu
- Multimeter Laserliner
- Multimeter Parkside
- Multimeter FERM
- Multimeter Stanley
- Multimeter Elro
- Multimeter REV
- Multimeter Elworks
- Multimeter Powerfix
- Multimeter Digitus
- Multimeter Alecto
- Multimeter Schneider
- Multimeter Basetech
- Multimeter Voltcraft
- Multimeter Testboy
- Multimeter Greenlee
- Multimeter Velleman
- Multimeter Somogyi
- Multimeter FLIR
- Multimeter Perel
- Multimeter JUNG
- Multimeter APPA
- Multimeter Amprobe
- Multimeter Fluke
- Multimeter Monacor
- Multimeter Brennenstuhl
- Multimeter Projecta
- Multimeter Maxwell
- Multimeter Testo
- Multimeter GW Instek
- Multimeter Brandson
- Multimeter Ideal
- Multimeter Multimetrix
- Multimeter Mastech
- Multimeter Högert
- Multimeter Brüder Mannesmann
- Multimeter Vimar
- Multimeter Klein Tools
- Multimeter PeakTech
- Multimeter Rigol
- Multimeter Joy-It
- Multimeter Wiha
- Multimeter HT Instruments
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Qian
- Multimeter Aim TTi
- Multimeter Steren
- Multimeter Gossen Metrawatt
- Multimeter Yato
- Multimeter Beha-Amprobe
- Multimeter Bearware
- Multimeter Sonel
- Multimeter Profile
- Multimeter Aldi
- Multimeter Amiko
- Multimeter Workzone
- Multimeter Tacklife
- Multimeter Etekcity
- Multimeter Digi-tool
- Multimeter Skandia
- Multimeter Elma
- Multimeter Hubinont
- Multimeter Kewtech
- Multimeter Strex
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter PCE Instruments
- Multimeter Micronta
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter IWH
- Multimeter Weltron
- Multimeter Sanwa
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter Caltek
- Multimeter Noyafa
Nyeste Multimeter Manualer
21 December 2024
18 December 2024
16 December 2024
15 December 2024
15 December 2024
15 December 2024
14 December 2024
14 December 2024
9 December 2024
8 December 2024