WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer or your distributor.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnect-
ing means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done
by a qualified person(s) in accordance with all ap-
plicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting. Fol-
low the heating equipment manufacturer's guideline
and safety standards such as those published by
the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigera-
tion and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
WARNING
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.
3. Please read specification label on product for
further information and requirements.
4. Electrical circuit, including speed control, (if used),
must be rated 6 AMPS minimum.
Blower Dimensions
28.25 x 24.75 x 7.17
PLAN THE INSTALLATION
1. Locate the ventilator so the length of the duct
run and number of elbows needed are kept to a
minimum.
2. Where possible, ventilator should be centered
between wall studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be
running through the wall.
ALL INSTALLATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
DEV900 120 5.7 900 10 " DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the out-
doors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
READ AND SAVE THESE INSTRUCTIONS
VIKING MODEL DEV900
EXTERIOR MOUNTED VENTILATOR
FOR USE WITH VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN, DTWS AND
DCIH RANGE HOODS. :-/-2+ 00' 30" TO 42" WIDE, TO 18" HIGH.9"


Produkt Specifikationer

Mærke: Viking
Kategori: Afzuigkap
Model: DEV900

Har du brug for hjælp?

Hvis du har brug for hjælp til Viking DEV900 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Afzuigkap Viking Manualer

Viking

Viking VWH3610RE Manual

9 September 2024
Viking

Viking TVWH360FW Manual

15 August 2024
Viking

Viking DEV900 Manual

5 August 2024
Viking

Viking TVWH660GB Manual

1 August 2024
Viking

Viking RVCH330DG Manual

1 August 2024
Viking

Viking VWH3610 Manual

31 Juli 2024
Viking

Viking G8MD Manual

29 Juli 2024

Afzuigkap Manualer

Nyeste Afzuigkap Manualer

Novy

Novy Canopy glass 874 Manual

16 September 2024
Scholtès

Scholtès H 5890 Manual

16 September 2024
Balay

Balay 3BT262MX Manual

16 September 2024
Smeg

Smeg KCVR9NE Manual

16 September 2024
Miele

Miele DA 419-4 SS Manual

16 September 2024
Bestron

Bestron TSCH80X Manual

16 September 2024
Westinghouse

Westinghouse WRR614SB Manual

16 September 2024
Zanussi

Zanussi ZH6020W/E Manual

16 September 2024