Vimar 01974 Manual


Læs nedenfor 📖 manual på dansk for Vimar 01974 (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 3 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
49400841A0 03 1910
01974
Actuator with 4 change-over relay outputs 16 A 120-230 V~,
programmable with control function for lights, roller shutters with
slat orientation, fan-coil, push-buttons for local control, By-me home
automation system, installation on DIN rails (60715 TH35), occupies 4
modules size 17.5 mm. Version for MARINE applications.
FEATURES.
Rated supply voltage: BUS 29 V.
Typical current draw: 20 mA.
4 relay outputs (N/C, C, N/O) for lights control; relays 1+2 and 3+4 can be
grouped for roller shutter control.
Can be used for the fan-coil function.
Push-buttons for manual relay control.
Push-button to enable/disable the manual controls.
LED for relay status.
LED and configuration button.
Protection class: IP20.
Operating temperature: -5 °C to +45°C (indoor use).
Overall dimensions: 4 modules of 17.5mm.
Compatible with By-me 21509 control units and EasyTool Professional.
CONTROLLABLE LOADS.
Relay output (controllable loads at 120 - 230 V~, N/O contacts):
- resistive loads : 16 A (20,000 cycles);
- incandescent lamps : 8 A (20,000 cycles);
- fluorescent lamps, with energy saving and LED : 0.5 A (20,000 cycles);
- electronic transform : 6 A (20,000 cycles);ers
Relay output (controllable loads at 120 - 230 V~, N/O and N/C contacts):
- cos ø 0.6 motors: 3.5 A (100,000 cycles).
MANUAL MANAGEMENT.
Pressing the button enables using the buttons to actuate the relays. All
messages from the bus are ignored.
• If the device is reset each relay is controlled with its own button.
If the device is configured, the relays configured individually are controlled by the
relevant button while the relays configured in pairs for roller shutter control are
controlled by the buttons for the UP function ( ) and DOWN function ( ) with a  
reversal time in the passage from UP to DOWN; whereas if they are configured for
fan-coil control, relays 1,2,3 are controlled alternately.
In normal operation, pressing the relay actuation buttons is ignored.
CONFIGURATION WITH BY-ME CONTROL UNIT OR EASYTOOL
PROFESSIONAL.
For full details see the relevant Installer manuals that can be downloaded
from the website www.vimar.com.
INSTALLATION RULES.
Installation should be carried out by qualified personnel in compliance with the
current regulations regarding the installation of electrical equipment in the country
where the products are installed.
• The 4 relay outputs are separated from each other by functional insulation at 250
V~ and not by double insulation; because of this, for example, do not connect a
SELV circuit to an output that is adjacent to another one that is connected to the
230 V~ power supply.
• The relay output power circuits must be protected against overcurrents by
installing devices or fuses with a rated breaking capacity of 1500 A or type-C
circuit breakers, with rated current not exceeding 16 A.
STANDARD CONFORMITY.
LV directive. EMC directive. Standards EN 60669-2-5, EN 50491.
For MARINE use, this device has been submitted to the following tests:
IEC 60068-2-52 - Test Kb: Salt mist, cyclic (sodium, chloride solution),
IEC 60068-2-6 - Test Fc: Vibration (sinusoidal)
This device complies with part 15 of the Rules (with the limits for a Class BFCC
digital device).
FRONT VIEW.
OUT 1 OUT 2 OUT 3
CNONC CNONC CNONC
BUSOUT 4
C NO NC
01974
SWITCH
ACTUATOR
OUT 2
OUT 1
OUT 3
OUT 4
CONF.
By-me
16A
μ
120-230V~50/60Hz
3,5A
M
A
C
NO
NC
B
C
D
E
F
NC
NO
C
C C
NO
NC
NO
NC
BUS line
Relay 1 Relay 2 Relay 3
Relay 4
A: LED and button to actuate relay 1
B: LED and button to actuate relay 2
C: LED and button to actuate relay 3
D: LED and button to actuate relay 4
E: LED and configuration button
F: Manual mode push-button
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesiderable
operation.
REACH (EU) Regulation no. 1907/2006 Art.33. The product may contain traces
of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be
included with other general waste at the end of its working life. The user must take the worn product to a sorted
waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free
of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m 2, if they measure
less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment and people’s health,
and encourages the re-use and/or recycling of the construction materials.


Produkt Specifikationer

Mærke: Vimar
Kategori: Ikke kategoriseret
Model: 01974

Har du brug for hjælp?

Hvis du har brug for hjælp til Vimar 01974 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vimar Manualer

Vimar

Vimar ELVOX 0931/240 Manual

17 November 2024
Vimar

Vimar ELVOX 6680/V04 Manual

17 November 2024
Vimar

Vimar ELVOX 6621 Manual

21 August 2024
Vimar

Vimar 08376 Manual

21 August 2024
Vimar

Vimar 14380 Manual

20 August 2024
Vimar

Vimar ELVOX 41215 Manual

20 August 2024
Vimar

Vimar ELVOX 1264 Manual

19 August 2024
Vimar

Vimar 19295.AC.M Manual

19 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024
Stamos

Stamos SPT10P805 Manual

22 November 2024