Vimar 19296 Manual


Læs nedenfor 📖 manual på dansk for Vimar 19296 (2 sider) i kategorien Stikkontakt. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Viale Vicenza, 14 - 36063 Marostica VI - Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188
Fax (Export) +39 0424 488 709
www.vimar.com
CLASS A GFCI 20A 125V
125V 15A RECEPT 60HZ
PAT.PEND.
T EST
T EST
RESET
RESET
LINE
GRN
HOT
WHITE
Receptacle
Outlet
Mounting
bracket
Grounding terminal (Green):
Connection for bare copper
or green wire
LINE
White terminal
(Silver):
Connection for
LINE cable’s
white wires
LOAD
White terminal
(Silver):
Connection for
LOAD cable’s
white wires
Screw (terminal) colors:
Green = Grounding terminal
Silver = White terminals
Brass = Hot terminals
LINE
Hot terminal (Brass):
Connection for the LINE
cable’s black wire
LOAD
Hot terminal (Brass):
Connection for the LINE
cable’s black wire
A yellow sticker covers
the LOAD terminals.
Do not remove the
sticker at this time
TEST button:
See “Procedure”
RESET button:
See “Procedure”
Trip
indicator light
49400555B0 02 1601
VIMAR - Marostica - Italy
Double 2P+E 15A 125 V 60 Hz socket outlet, American standard, with ground fault circuit interrupter (GFCI) and built-in mounting frame, to ~
complete with 3-module cover plate.
DESCRIPTION.
A GFCI receptacle is different from conventional receptacles. In the event of a ground
fault, a GFCI will trip and quickly stop the flow of electricity to prevent serious injury.
CHARACTERISTICS.
Rated voltage 125 V 60 Hz.~
• Rated current corresponding to the socket outlet standard 15 A.
GFCI Class A (trip 6 mA or more).
ATTENTION:
If you install the device in the Eikon Evo cover plate,
make sure to remove the side lugs as shown in the
picture beside.
Definition of a ground fault:
Instead of following its normal safe path, electricity passes through a person’s body
to reach the ground. For example, a defective appliance can cause a ground fault. A
GFCI receptacle does not protect against circuit overloads, short circuits, or shocks.
For example, you can still be shocked if you touch bare wires while standing on a
non-conducting surface, such as a wood floor.
TEST YOUR WORK.
Why perform this test?
If you miswired the GFCI, it may not prevent personal injury or death due to a
ground fault. (electrical shock).
If you mistakenly connect the LINE wires to the LOAD terminals, the GFCI will still
operate like an ordinary receptacle, but it will not interrupt a ground fault.
T EST
T EST
RESE
SET
TES
EST
RESET
RESET
TEST
TEST
RES
SET
Procedure:
(a) - This GFCI is shipped from the factory in the trip
ped condition and can not be reset until it is wired
correctly and power is supplied to the device.
Plug a lamp or radio into the GFCI (and leave it
plugged in). Turn the power ON at the service
panel. Press the RESET button fully, make sure
the lamp or radio is ON. If the lamp or radio is still
OFF or the RESET button can not be engaged,
go to the Troubleshooting section because LINE
and LOAD wiring connection have been reversed.
(b) Press the TEST button fully, the GFCI will trip
and the lamp or radio will be OFF. To restore
power, press the RESET button.
(c) If you installed your GFCI using CONNECTION
B, plug a lamp or radio into surrounding
receptacles to see which one(s), in addition to
the GFCI, lost power when you pressed the
TEST button. Do Not plug life saving devices
into any of the receptacles that lost power.
Place a “GFCI Protected” sticker on every
receptacle that lost power. Then press the
RESET button to reset the GFCI.
(d) Press the TEST button (then RESET button)
every month to assure proper operation. If the
GFCI can not be reset, then it must be replaced.
(e) If the GFCI consistently trips it indicates end of
life and GFCI must be replaced.
TROUBLESHOOTING.
Turn the power OFF and check the wire connections against the appropriate wiring
diagram in step CONNECTION A or CONNECTION B. Make sure that there are no loose
wires or loose connections. Also, it is possible that you reversed the LINE and LOAD
connections. LINE/LOAD reversal will be indicated by power remaining ON at the GFCI
after you press the GFCI’s TEST button. Reverse the LINE and LOAD connections if
necessary. Start the test from the beginning if you rewired any connections to the GFCI.
CAUTION.
To prevent severe shock or electrocution always turn the power OFF at the service
panel before working with wiring.
PLACEMENT IN CIRCUIT:
The GFCI’s place in the circuit determines if it protects other receptacles in the circuit.
Placing the GFCI in position A will also provide protection to “load side” receptacles B and C. On the other
hand, placing the GFCI in position C will not provide protection to receptacles A or B. Remember that
receptacles A, B and C can be in different rooms.
FRONT VIEW BACK VIEW
LINE
GRN
LOAD
HOT
WHIT E
LINE cable brings
power to the GFCI
Mounting box
LOAD cable feeds power
to other receptacle(s)
Grounding
connection to box
(if box has a
grounding terminal)
Wire connector
Yellow sticker remain
in place to cover the
LOAD terminals
LINE
GRN
HOT
WHIT E
ATTENTION
LINE cable brings
power to the GFCI
Wire connector
Mounting box
Grounding
connection to box
(if box has a
grounding terminal)
CONNECTION B.
CONNECTION A.
T EST
T EST
RESET
RESET
LINE
LOAD
LINE
LOAD
A
LINE
B C
Service
Panel
SAMPLE CIRCUIT:
Eikon Evo
21296
Idea
16296
Plana
14296
Arké
19296
Use this GFCI receptacle with copper or copper-clad wire. Do not use it with aluminum wire.
Do not install this GFCI receptacle on a circuit that powers life support equipment because if the GFCI
trips it will shut down the equipment.
Must be installed by a skilled person in accordance with national and local electrical codes.
EIKON EVO
MADE
N
ITALY


Produkt Specifikationer

Mærke: Vimar
Kategori: Stikkontakt
Model: 19296

Har du brug for hjælp?

Hvis du har brug for hjælp til Vimar 19296 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Stikkontakt Vimar Manualer

Vimar

Vimar 14222.SL Manual

19 August 2024
Vimar

Vimar 20340.1.B Manual

19 August 2024
Vimar

Vimar 19339.11.B Manual

19 August 2024
Vimar

Vimar 19219 Manual

18 August 2024
Vimar

Vimar 20339.6.B Manual

18 August 2024
Vimar

Vimar 20222.L Manual

17 August 2024
Vimar

Vimar 14339.13 Manual

16 August 2024
Vimar

Vimar 14214.SL Manual

16 August 2024
Vimar

Vimar 20345.N Manual

16 August 2024
Vimar

Vimar 20257.B Manual

16 August 2024

Stikkontakt Manualer

Nyeste Stikkontakt Manualer

Powerfix

Powerfix IAN 53443 Manual

15 Oktober 2024
Kogan

Kogan KASPUSBAC2A Manual

1 Oktober 2024
Philips

Philips 18952C2 Manual

1 Oktober 2024
Emos

Emos P0423R Manual

24 September 2024
Emos

Emos P0325R Manual

24 September 2024
Emos

Emos P1621 Manual

24 September 2024
Emos

Emos PC1421R Manual

24 September 2024
Emos

Emos PC1521R Manual

24 September 2024